5
6.3 OSD Menu
1
IN
576i
OUT
WXGA
2
Phase Adjust
3
IN Color Space
4
H Position
5
V Position
6
Field Invert
7
Information
8
System Reset
Exit
1
The first part of the OSD will display the current input and output
resolutions.
2
Phase Adjust has a total of 32 steps for adjusting the phase,
ranging from 0~31. Press the button repeatedly to adjust the phase
setting whenever changing the source equipment. The device will
keep memory of the last phase adjustment.
3
IN Color Space for selecting between CGA (RGB) or Component
(YCbCr) input signals.
4
H Position has total of 20 horizontal positions ranging from −10 ~ +10.
5
V Position has total of 10 vertical positions ranging from −5 ~ +5.
6
Field Invert can be used to fix the even/odd field problem. Select
Yes to correct the issue when the display image appears to be
field inverted.
7
Information displays the settings for input signal, color space, field
inversion and firmware version.
8
System reset will revert the device back to the factory default
settings.