9
Press the hot key to select the input sources.
9
720p/1080p@50/60*
Press the hot key to select 720p@50 Hz, 720p@60 Hz, 1080p@50 Hz
and1080p@60 Hz timings for HDMI output, the SDI output timings
will be automatically converted to SMPTE 292M (1.485 Gbit/s) and
SMPTE 424M/425M (2.970 Gbit/s)
10
U/OVER
Press this key to change the output image to be overscan or
underscan.
*Function that automatically adjusts all monitors in once.
6.5 RS-232 Pin Assignments
RS-232 IN
RS-232 OUT
PIN
Assignment
PIN
Assignment
1
NC
1
NC
2
TxD
2
RxD
3
RxD
3
TxD
4
NC
4
NC
5
GND
5
GND
6
NC
6
NC
7
NC
7
NC
8
NC
8
NC
9
NC
9
NC
Baud Rate: 19200 bps
Data bit: 8-bit
Parity: None
Stop Bit: 1
Flow Control: None