8. SPECIFICATIONS

Input Ports

9 x Button
1 x Control

Output Ports

1 x Relay

Power Supply

5VDC/2.6A (US/EU standards, CE/FCC/ UL 

certified)

ESD Protection

Human body model: 
±8 kV (air-gap discharge) 
±4 kV (contact discharge)

Dimensions

87mm(W)x87mm(D)x31mm(H)
/Jacks Excluded
87mm(W)x87mm(D)x34mm(H)

/Jacks Included

Weight

 184  g

Chassis Material

Metal

Color

White

Operating 
Temperature

0˚C~40˚C/32˚F~104˚F

Storage Temperature

−20˚C~60˚C/−4˚F~140˚F

Relative Humidity

20~90% RH (non-condensing)

Power Consumption

3.9 W

Summary of Contents for CDPW-K1S

Page 1: ...CDPW K1S UK 1 Gang 9 Button Wall Plate Control Keypad Operation Manual Operation Manual...

Page 2: ......

Page 3: ...chnology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stor...

Page 4: ...his product Never push an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to buildin...

Page 5: ...6 1 Front Panel 3 6 2 Rear Panel 4 6 3 Telnet Commands 5 6 4 Software Application 7 6 5 Telnet Control 8 6 6 WebGUI Control 10 6 6 1 Macro Settings 11 6 6 2 Extension Marco 14 6 6 3 Command Settings 1...

Page 6: ...ion ease power supply issue without extra DC power burden Further relay outputs design and scheduling function control settings can trigger master switch or any main switch of the installation environ...

Page 7: ...of other devices Supports Scheduling control system and settings Supports scheduling memory over power blackout up to 48hrs Supports Key Pad Telnet and WebGUI controls Supports PoE function or DC powe...

Page 8: ...FUNCTIONS 6 1 Front Panel PC 1 Apple TV HDMI 1 Laptop 1 Blu ray 1 SKYHD System On System Off Media Player 9 1 1 1 9 Macro Buttons Each buttons has 2 colors of LEDs adjustable from dim 0 100 and can b...

Page 9: ...trol Connect from PC Laptop with active internet service or Telnet or WebGUI control with RJ 45 terminated cable This slots supports PoE PD 48V function which means when the connected server Hub suppo...

Page 10: ...XXX Set Ethernet Gateway XXX 0 255 SIPMODE N SET ETHERNET IP MODE N STATIC DHCP VER Show Unit Firmware Version NONE FADEFAULT ALL CONFIGURE and Macro SET TO FACTORY DEFAULT NONE ETH_FADEFAULT ALL ETH...

Page 11: ...DSHOW N LED DIMMING MODE CONTROL LEDSHOW N N ON OFF TOGGLE BACKLIGHT N ALL LED BACKLIGHT CONTROL N 0 100 KEY_PRESS N RELEASE KEY_PRESS N HOLD KEY PRESS TRIGGER TYPE KEY_PRESS N RELEASE N PORT NUMBER K...

Page 12: ...ontrol System with PC Laptop through the Ethernet port of an active network system and open the CDPS V2 000 application Click on Find Devices on Network and a list of the devices connected to the Cont...

Page 13: ...under MS windows click Start menu and type cmd in the search field then press enter Under Mac OS X go to Go Application Utilities Terminal See below for reference Once in the command line interface C...

Page 14: ...bring up all available commands Note Any commands will not be executed unless followed by a carriage return Commands are case insensitive If the IP is changed then the IP Address required for Telnet a...

Page 15: ...n the web address entry bar Note The Default IP setting is on Static with address at 192 168 1 50 A security page will appear to ask for User and Password please key in admin for both to enter The bro...

Page 16: ...h 100 brightness sequentially from 1 8 with every 500ms Macro 2 Light up the Blue backlight LED with 100 brightness sequentially from 1 8 with every 500ms Macro 3 Switch off all the read backlight LED...

Page 17: ...own and button is to delete the command Click on Insert button Add to insert commands Command can be set to control the Wall Plate Control Box SysCMD other devices connected within the same Telnet sys...

Page 18: ...thin the same telnet system or internet area require to set its IP and Port number and it is strongly recommand to set the delay time 500ms in order to secure a successful command sending Once the set...

Page 19: ...rs and under 512 characters including space can be build up to 32 command in addition with 96 commands of 128 characters under Click on Save Change to save the command inserted 6 6 4 Schedule Click on...

Page 20: ...15 Click on Edit from Repeat column to set the macro command s to be activated repeatedly on a set time Click on Edit from Once column to set the macro command s to be activated on a set time only...

Page 21: ...16...

Page 22: ...on System Settings to reset the WebGUI login password and timeout setting and save or download the Macro settings Reset to Default allows IP and login ID password to be reset back to factory default S...

Page 23: ...t the system time and to enable disable Daylight Saving Time DST function Simply click on the white column and a calendar will appear for your selection with current timing setting Another simple few...

Page 24: ...19 7 CONNECTION DIAGRAM CONTROL DC 5V RELAY OUT Wireless Ethernet With Internet Connection Power Supply Lamp...

Page 25: ...ion Human body model 8 kV air gap discharge 4 kV contact discharge Dimensions 87mm W x87mm D x31mm H Jacks Excluded 87mm W x87mm D x34mm H Jacks Included Weight 184 g Chassis Material Metal Color Whit...

Page 26: ......

Page 27: ......

Page 28: ...Home page http www cypress com tw CYPRESS TECHNOLOGY CO LTD MPM CDPWK1S...

Reviews: