3
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
1
2
3
4
5
6
7
1
POWER DC 5~24V:
The device support power supply from
5~24V/2.6~1.25A, plug the 24V DC power supply from the included
package into the unit and connect the adaptor to an AC outlet.
2
CONTROL:
This slot is to connect with active LAN system for IP
control.
3
SERVICE:
This slot is reserved for firmware update only.
4
CONSOLE:
Connect to a PC or Laptop via RS-232 terminal to D-Sub
9-pin cable for the transmission of RS-232 commands and Ethernet
rest.
5
OUT DEF.:
These slots are to connect with comport control devices
such as RS-232/422/485 or DMX512 with RS baud rate up to
115200 and DMX baud rate fix at 250 Kbit/s unidirectional, serial
transmission and daisy-chain configuration up to 512 nodes of max
time 22ms (roughly 44Hz).
6
PWM OUT (10V):
These slots are to connect up to 8 devices of
voltage set at 10 for control over PWM which can be adjust
through command from 0 ~100% duty cycle at 30 ~1200Hz
frequency.
7
VOLTAGE OUT (0~10V):
These slots are to connect up to 8 devices
of voltage anywhere from 0 ~10 volt. For control over DAC with
adjustable voltage at 0.1 per scale through command setting.