CYCLOPS NOVA OSD Manual Download Page 7

.

1、 As GPS beginning to search satellites, the satellite number is indicated by the

GPS strength icon on the upper right corner. A flashing icon indicates weak or

unreliable GPS strength and take-off in this situation is not recommended.(with

good GPS signal, the satellite searching would last 1-5 minutes depending on

different circumstances)

2、 Press and hold the setting button for 3 seconds, the units will switch between

from Metric and Imperial. The OSD will remember your setting.

3、 Set up the IR sensors correctly, mount it horizontally on your plane, and keep no

devices block the 2 sensors on the board. Keep the IR sensor from the video Tx,

which may affect the sensor.

4、 There are 3 modes for Nova OSD, you can connect one spare channel of your

radio and use a 3-position stick to switch the modes. When the gps get signals,

Summary of Contents for NOVA OSD

Page 1: ...NOVA NOVA NOVA NOVA OSD OSD OSD OSD V1 0 V1 0 V1 0 V1 0 manual manual manual manual Thanks for choosing the Cyclops products...

Page 2: ...Name Name Name Name Quantity Quantity Quantity Quantity Param Param Param Param NOVA OSD mainboard 1 GPS module 1 10Hz 100A Current sensor 1 50V 100A Infrared sensor 1 Servo lead 4 20cm Infrared senso...

Page 3: ...wer of your motor WARNING in this situation you motor lipo should be 3s or you will damage the OSD or your video devices When the jumper connects the pin 2 and 3 the current sensor just offer the volt...

Page 4: ...r User User User guide guide guide guide Connect the equipments as above the gps must be connected power it on the red LED will flash and the Nova OSD will show start up screen as below Before the sta...

Page 5: ...r should be mounted on the plane horizontally and keep the arrow marked on the sensor head to the front of the plane Hold your plane and make one of the wing head to the sky the other wing head to the...

Page 6: ...pull your elevator to the bottom and push the Aileron to the right end When the word OK appear which shows the process is done when the word Error appear please do it again ELEVON ELEVON ELEVON ELEVON...

Page 7: ...g on different circumstances 2 Press and hold the setting button for 3 seconds the units will switch between from Metric and Imperial The OSD will remember your setting 3 Set up the IR sensors correct...

Page 8: ...e screen 7 You can connect one spare channel of your radio to the display mode pins then you can switch 3 screens the simple screen the F 16 screen and blank screen In the simple screen The H on the s...

Page 9: ...inkDare receiver for the future bi direction communication application 11 NOVA OSD can show analog RSSI voltage on the top left side the voltage detect range is 0 1 3 3V when the voltage is less the 0...

Page 10: ......

Reviews: