5
Don’t put or install the device on a surface that subject to vibration or bumps.
Ta=4
5℃
The device is supposed to work in the temperate range -15° C and +45° C, do not use the device
when the temperate exceed this range.
The lens, shield need to be replaced when obviously broken, never use the device when the shield is
not completed closed.
Safety I class device, need to be earth connected.
When the fixture is hanged overhead, the safety rope must be fixed to the bottom of the device to
the appropriate fixing point.
Always carry the device by the handles, do not take the head or arm directly for transportation.
2.2 Maintenance
2.2.1 Operation only allowed to qualified person, damages due to unprofessional operation or remove of any parts
inside will not be considered in warranty service. There are no serviceable parts inside the device or package, service
only leaves to authorized dealers.
2.2.3 Never allow the optical components contact with oil, fat or any other liquid.
2.2.4 A regular clearance of the device is needed for long-term usage, this is very helpful to maintain the lifetime and
brightness need to use a soft and lint-free cloth to clean the optical system, fan and air flowing tunnel.
2.2.5. Trouble Shooting
Problems
Possible reasons
Checking or solutions
Device not power up
Powercon or power cable damaged
Faulty power supply
Change a good power cable to try
Replace new power supply
Pan/Tilt error or vibrate
Faulty Pan/Tilt PCB
Faulty opto sensor
Cable loosen
Replace PT001 PCB
Replace opto sensor OP001
Check the cable connect to OP001
Lamp off
Temperature protection
Fan not working
Faulty Lamp
Dimmer and strobe set at 0
Faulty power supply
Check the temperature from menu
Check the fan speed info from menu
Replace new Lamp
Set dimmer and strobe channel at 255
Replace new power supply
Device not response to DMX Faulty communication IC
Faulty display PCB
Wrong DMX addressing
Faulty DMX cable
Replace the IC with back-up one in the display PCB
Replace new display PCB
Check the address and setting
Change to a good DMX cable
2.2.6 Replacement of the fuse
Need to replace with same type and rating, which originally installed in the device.
Step One: Unplug power cable from main power.
Step Two: Unscrew the fuse holder out of the housing with a screwdriver.
Step Three: Remove the broken fuse and replace with an exact same type of new fuse.
Step Four: Insert the fuse holder back to the housing and screw tight and reconnect power.