background image

USER MANUAL

PAR-150FZ 

150 watts powered RGBW LED par with Zoom

Summary of Contents for PAR-150FZ

Page 1: ...USER MANUAL PAR 150FZ 150 watts powered RGBW LED par with Zoom ...

Page 2: ...n a truss 4 Securing with a safety cable 4 DMX 512 connection connection between fixtures 4 Power connection 5 Operation 5 Control Menu Map 5 Addressing 6 Universal DMX Control 6 RDM control 6 Zoom function 7 DMX Protocol 7 ID address selection 8 Fixture Cleaning 8 Fuse Replacement 9 Troubleshooting 9 The fixture does not work no light 9 Technical specifications 9 Table of contents ...

Page 3: ...s of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of th...

Page 4: ...an be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging vertically down you can use an open type clamp such as a G clamp When installing in any other orientation you must use a half coupler clamp that completely encircles the truss chord To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times the weight o...

Page 5: ...d between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Power connection Power Requirements The PAR 150FZ LED luminaire operates on 100 to 240 volts A...

Page 6: ...ting address for all fixtures or a group of fixtures or make different address for each fixture individually If you set the same address all the units will start to listen to the same control signal from the same channel number In other words changing the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel...

Page 7: ...allows you to adjust the beam width of the fixture manually Simply rotate the rotary knob in the display panel to control the zoom right stop maximum spot left stop minimum spot DMX Protocol 1 Channel Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer 2 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer CH2 Strobe 000 255 Strobe with speed increasing 3 Channels Mod...

Page 8: ...D address DMX value Function DMX value Function DMX value Function 000 009 ID1 ID66 212 ID23 235 ID46 010 019 ID1 213 ID24 236 ID47 020 029 ID2 214 ID25 237 ID48 030 039 ID3 215 ID26 238 ID49 040 049 ID4 216 ID27 239 ID50 050 059 ID5 217 ID28 240 ID51 060 069 ID6 218 ID29 241 ID52 070 079 ID7 219 ID30 242 ID53 080 089 ID8 220 ID31 243 ID54 090 099 ID9 221 ID32 244 ID55 100 109 ID10 222 ID33 245 ID...

Page 9: ... solution Do not rub glass surfaces hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Fuse Replacement This fuse is located in a fuseholder next to the MAINS OUT s...

Page 10: ...inum IP rating 20 Operating temperature 5 C 45 C www cyclopslighting com Model PAR 150FZ Light source 150 watts RGBW COB LED LED life expectancy 50 000 Hrs Manual zoom Zoom range 25 to 80 Color mixing RGBW 5 Dimmer curves Strobe Video flickerfree with selectable PWM Built in color macros Barn doors included Control protocols RDM DMX Control channels ARC 1 3CH AR1 D 4CH ARC 2 4CH AR2 D 5CH AR2 S 6C...

Reviews: