background image

6

V1.0

www.ovationlight.com

1. Group

2. Signal (-)

3. Signal (+)

DMX OUT

1. Group

2. Signal (-)

3. Signal (+)

DMX IN

If you are using controllers with this occupation, you can connect the DMX-output of the controller directly 

with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other 

XLR-outputs, you need to use adapter-cables.

Building a serial DMX-chain:

Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture.

Always connect one output with the input of the next fixture until all fixtures are connected.

DMX-512 connection with DMX terminator:

For installations where the DMX cable has to run a long distance or is in an electrically noisy 

environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in 

preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an 

XLR plug with a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR 

socket of the last fixture in the chain.

Caution: 

At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω 

resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the 

last fixture.

Power connection

Power Requirements

The FR-50T  luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains 

an auto-ranging power supply.

Connection with the mains:

Connect the device to the mains with the enclosed power supply cable.

The occupation of the connection cables as below:

Cable color

Connection

International

Brown 

Live

L

Blue 

Neutral

N

Yellow/green

Earth(Ground)

Operation

The FR-50T  can operate in three different modes. In each mode you can run the fixture as a stand alone 

fixture or in a master/slave confiugration. This next section will detail the differences in the operating 

modes.

Addressing

All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture

responds to the correct control signals. This digital starting address is the channel number from which 

the fixture starts to listen to the digital control information sent out from the DMX controller. The allocation 

Summary of Contents for FR-50T

Page 1: ...USER MANUAL FR 50T Tunable White Super Compact LED Fresnel ...

Page 2: ...nting the fixture on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Addressing 6 Universal DMX Control 7 Rotary control 7 Zoom 7 Control Menu Map 8 DMX Protocol 8 Fixture Cleaning 9 Fuse Replacement 9 Troubleshooting 9 The fixture does not work no light 9 Technical specifications 10 Table of contents ...

Page 3: ...tain parts of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service l...

Page 4: ...ace or leave it where it can be moved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails Fastening the fixture to a flat surface The fixture can be fastened to a hard fixed flat surface that is oriented ...

Page 5: ...tures and equipment to be installed on it 2 Block access under the work area 3 Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket The bolt used must be M10 grade 8 8 steel minimum It must pass through both mounting bracket legs and be fastened with a self locking nut 4 Working from a stable platform hang the fixture with its clamp on the truss ...

Page 6: ...output XLR socket of the last fixture in the chain Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ω resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Power connection Power Requirements The FR 50T luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging po...

Page 7: ...ill affect only the selected fixture In the case of the FR 50T which is 1 2 3 5 channels fixture If you set for example the address in the 1 channel mode to channel 2 the device will use the channel 2 for control Note After switching on the device will automatically detect whether DMX 512 data is received or not If there is data received at the DMX input the dot in the display will flash Universal...

Page 8: ...Menu Map MENU SUB MENU OPERATION Addr d001 d512 RDM DMX address CHnL 1CH Channel mode 2CH 3CH 5CH Strb S 01 s 20 Strobe with spead increasing uL u 000 u 255 WW dimmer CL C 000 C 255 CW dimmer UOL 000 255 Rotary control of dimmer nodE nod 0 Dimmer speed 0 no delay nod 1 Dimmer speed 1 nod 2 Dimmer speed 2 nod 3 Dimmer speed 3 nod 4 Dimmer speed 4 slowest speed tEnP 25 100 Fixture temperature UErn F...

Page 9: ...t dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp output To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean l...

Page 10: ...ED Color temperature 2700K 6500K tunable LED life expectancy 50 000 Hrs CRI 95 R9 90 TLCI 98 Manual zoom Zoom range 25 to 90 manual Light output 14 000 Lux 1m 25 5 Dimmer curves Strobe Video flicker free PMMA polymethyl methacrylate lens Barn doors included Control protocols Rotary DMX RDM Control channels 1 2 3 4 CHs Input voltage AC100 240V 50 60Hz DMX Connections 3 pin XLR In Out male and femal...

Page 11: ...11 V1 0 www ovationlight com www cyclopslighting com 156MM 211MM 306MM 230MM 279MM 185MM Please note All information is subject to change without prior notice ...