background image

3

V1.0

Caution!

Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric 

shock when touching the wires!

Avoid looking directly into the light source!

Wear protective glasses and other PPE (personal protective equipment) when working on or near 

the fixture.

For your own safety, please read this user manual carefully before you initial start-up.

Follow operating safety precautions and pay attention to warning signs methods and equipment 

on the user manual.

Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 

20 rating.

The ambient temperature must always be between -5° C and +45° C. 

Always make sure you are connecting this product to the proper voltage in accordance with the 

specifications in this manual or on the product’s specification label.Make sure it is grounded when 

using it!

Unplug mains lead before opening the housing!

Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture 

and the powercord from time to time.

Make sure to replace the fuse with another of the same type and rating.

Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot 

during operation. After use, wait for a cool-down period of at least 10 minutes before handling or 

transporting the device.

Every person involved with the installation, operation and maintenance of this device has to

- be qualified

- follow the instructions of this manual

- consider this manual to be part of the total product

- keep this manual for the entire service life of the product

- pass this manual on to every further owner or user of the product

- download the latest version of the user manual from the Internet

Introduction

Thank you for having chosen FR-40C. You will see you acquired a powerful and versatile device.

Unpack your item. Before you initial start-up, please make sure that there is no damage caused by 

transportation. Should there be any, consult your dealer and do not use the device.

Safety instructions

This device has left our premises in absolutely perfect condition. In order to maintain this condition and 

to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and 

warning notes written in this user manual. Always disconnect from the mains, when the device is not in 

use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable 

parts inside the device. Maintenance and service operations are only to be carried out by authorized 

dealers.

Summary of Contents for FR-40C

Page 1: ...USER MANUAL FR 40C Warm White Super Compact LED Fresnel...

Page 2: ...ng the fixture on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Addressing 7 Universal DMX Control 7 Rotary control 7 Zoom 8...

Page 3: ...f the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operat...

Page 4: ...esigned for indoor use only and must be used in a dry location with adequate ventilation Ensure that none of the fixture s ventilation slots are blocked Fasten the fixture to a secure structure or sur...

Page 5: ...ord To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it 2 Block access under the work area 3...

Page 6: ...n of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the...

Page 7: ...unit will start to listen to the channel number you have set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selected fixtur...

Page 8: ...MENU OPERATION Addr d001 d512 RDM DMX address CHnL 1CH Channel mode 2CH 3CH 4CH Strb S 01 s 20 Strobe with spead increasing uL u 000 u 255 Key control of dimmer UOL 000 255 Rotary control of dimmer n...

Page 9: ...dimmer CH2 Strobe 000 255 strobe with speed increasing CH3 Dimmer mode 000 255 Dimmer speed 0 no delay 000 255 Dimmer speed 1 000 255 Dimmer speed 2 000 255 Dimmer speed 3 000 255 Dimmer speed 4 slow...

Page 10: ...ct the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean th...

Page 11: ...ED LED Color temperature 5600K LED life expectancy 50 000 Hrs CRI 97 R9 90 TLCI 96 Manual zoom Zoom range 25 to 90 manual Light output 14 000 Lux 1m 25 5 Dimmer curves Strobe Video flicker free PMMA p...

Page 12: ...12 V1 0 Please note All information is subject to change without prior notice 20 06 2018 156MM 211MM 306MM 230MM 279MM 185MM www cyclopslighting com...

Reviews: