In the case of the FR-300W, which is 1/2/3/4 channels fixture. If you set, for example, the address in the 

1 channel mode to channel 2, the device will use the channel 2 for control.

Note: After switching on, the device will automatically detect whether DMX 512 data is received or 

not. If there is data received at the DMX input, you will see the DMX indicator light in green.

Universal DMX Control

This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX 

controller allows you to create unique programs tailored to your individual needs.

RDM control

The FR-300W LED can communicate using RDM (Remote Device Management) in accordance with 

ESTA’s American National Standard E1.20-2006: Entertainment Technology RDM Remote Device 

Management Over DMX512 Networks.

RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open 

standard for DMX512 device configuration and status monitoring.

The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting 

existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to 

and receive messages from specific fixtures.

With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful 

when the device is installed in a remote area.

Each FR-300W  has a factory set RDM UID (unique identification number).

Note: Before operation, enable RDM function in Advanced settings.

Art-Net protocol

The fixtures on a data link are connected to the Ethernet with Art-Net™ communication protocol. The 

control software running on your PC (or light console) has to support Art-Net protocol.

Art-Net™ communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP. Its purpose is 

to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.

Summary of Contents for FR-300W

Page 1: ...USER MANUAL FR 300W 300 watts Warm White LED Fresenels...

Page 2: ...ble 6 DMX 512 connection connection between fixtures 6 Art Net Connection 7 Power connection 7 Operation 8 Control Menu Map 8 Control menu 9 Main Menu 9 Addressing 9 Universal DMX Control 10 RDM contr...

Page 3: ...f the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operat...

Page 4: ...door and color frame holder Handle Net out LCD display Menu button Up button Down button Enter button Net in Fuse Power in On off switch Safety cable anchor point Dmx out Dmx in Dmx signal indicator...

Page 5: ...l over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed below with a securely anchored safety cable that will hold the fixture if the prim...

Page 6: ...fails Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring point Do not loop the safety cable around the fixture s mounting bracket only as this will leav...

Page 7: ...ended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins...

Page 8: ...slave confiugration This next section will detail the differences in the operating modes Control Menu Map Default setting in bold MAIN MENU LEVEL 1 LEVEL 2 LEVEL 3 FUNCTION INSTRUCTION DMX 001 512 DM...

Page 9: ...n Only qualified technicians should perform this function Inqure your local dealer for password Signal Priority DMX DMX Art Net signal priority setting ArtNet Signal Hold On Off Run if signal cut RDM...

Page 10: ...he correct number on the display located on the base of the device You can set the same starting address for all fixtures or a group of fixtures or make different address for each fixture individually...

Page 11: ...ns protocol for use in DMX512 control systems it is the open standard for DMX512 device configuration and status monitoring The RDM protocol allows data packets to be inserted into a DMX512 data strea...

Page 12: ...ress ENTER 3 Press DOWN menu and select Manual sub menu 4 Press ENTER and select Brightness or Strobe in third menu 5 Rotate the rotary knob to control the dimmer right stop maximum output left stop z...

Page 13: ...13 V1 0 Up Down Enter function The knob can also act as up down and enter function 1 Press the MENU button to enter the main menu interface 2 Right rotation Down left rotation Up press Enter function...

Page 14: ...or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Select disired dimmer mode Custom dimmer curves 1 Press the MENU button to enter the main menu 2 Press...

Page 15: ...on a monthly basis Periodic cleaning will ensure longevity and crisp output To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently bl...

Page 16: ...TLCI 98 Zoom range 15 to 50 motorized 5 Dimmer curves Color Warm white Light output 8 500 Lux 5m 15 Control protocols RDM Artnet DMX control Control channels 1 2 3 4 CHs Flicker free with selectable...

Reviews: