background image

5

Version 1.0

Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over. 

If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed 

below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.

Mounting the fixture on a truss

The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the 

fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in 

any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.

To clamp the fixture to a truss:

1. 

Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment 

to be installed on it.

2.  Block access under the work area.

3.  Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting 

bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting 

bracket legs and be fastened with a self-locking nut.

4. 

Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp 

securely.

5. 

Secure the fixture with a safety cable as directed below.

Securing with a safety cable

Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of 

the fixture so that the safety cable will hold the fixture if a primary attachment fails.

Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring point. 

Do not loop the safety cable around the fixture’s mounting bracket only, as this will leave the fixture 

unsecured if it separates from the bracket.

DMX-512 connection/connection between fixtures

Occupation of the XLR-connection:

1. Group

2. Signal (-)

3. Signal (+)

DMX OUT

1. Group

2. Signal (-)

3. Signal (+)

DMX IN

I

f you are using controllers with this occupation, you can connect the DMX-output of the controller directly 

with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other 

XLR-outputs, you need to use adapter-cables.

Building a serial DMX-chain:

Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture.

Always connect one output with the input of the next fixture until all fixtures are connected.

DMX-512 connection with DMX terminator:

For installations where the DMX cable has to run a long distance or is in an electrically noisy 

environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in 

preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an 

Summary of Contents for FR-200F

Page 1: ...USER MANUAL FR 200F 200 watts RGBW powered LED Fresnel...

Page 2: ...a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 DMX Proto...

Page 3: ...s of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation ope...

Page 4: ...eave it where it can be moved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed in this user manual using a securely anchored...

Page 5: ...cable as directed below Securing with a safety cable Secure the fixture with a safety cable or other secondary attachment that is approved for the weight of the fixture so that the safety cable will...

Page 6: ...l all are connected Caution maximum power linking 8 units Connection with the mains Connect the device to the mains with the enclosed power supply cable The occupation of the connection cables as belo...

Page 7: ...ging the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel number you have set based on the quantity of c...

Page 8: ...olor preset color temp 000 010 No function 011 030 Red 100 Green0 100 Blue 0 031 050 Red 100 0 Green 100 Blue 0 051 070 Red 0 Green 100 Blue 0 100 071 090 Red 0 Green 100 0 Blue 100 091 110 Red 0 100...

Page 9: ...peed CH12 ID address setting 000 009 ID1 ID66 010 019 ID1 020 029 ID2 030 039 ID3 200 209 ID20 210 ID21 211 ID22 255 ID66 ARC 1 3 Channels Mode Function Function Control CH1 Red 000 255 0 100 Red dimm...

Page 10: ...00 White dimmer CH6 Strobe 000 255 Strobe with speed increasing HSV 3 Channels Mode Function Function Control CH1 Hue 000 255 0 100 Hue CH2 Saturation 000 255 0 100 Saturation CH3 Value brightness 000...

Page 11: ...dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solut...

Page 12: ...nt temperature control Silent operation PMMA polymethyl methacrylate lens Barn doors included Control protocols DMX RDM Control channels ARC 1 3CH AR1 D 4CH ARC 2 4CH AR2 D 5CH AR2 S 6CH HSV 3CH STAG...

Reviews: