background image

4

Version 1.0

Overview

Installation

Read ‘Safety information’ before installing the fixture.

The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. 

Ensure that none of the fixture’s ventilation slots are blocked.

Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can 

be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, 

secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if 

the primary fastening method fails.

Fastening the fixture to a flat surface

The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure that the 

surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to 

be installed on it.

Summary of Contents for FR-200F

Page 1: ...USER MANUAL FR 200F 200 watts RGBW powered LED Fresnel...

Page 2: ...a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 DMX Proto...

Page 3: ...s of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation ope...

Page 4: ...eave it where it can be moved or fall over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed in this user manual using a securely anchored...

Page 5: ...cable as directed below Securing with a safety cable Secure the fixture with a safety cable or other secondary attachment that is approved for the weight of the fixture so that the safety cable will...

Page 6: ...l all are connected Caution maximum power linking 8 units Connection with the mains Connect the device to the mains with the enclosed power supply cable The occupation of the connection cables as belo...

Page 7: ...ging the settings of one channel will affect all the fixtures simultaneously If you set a different address each unit will start to listen to the channel number you have set based on the quantity of c...

Page 8: ...olor preset color temp 000 010 No function 011 030 Red 100 Green0 100 Blue 0 031 050 Red 100 0 Green 100 Blue 0 051 070 Red 0 Green 100 Blue 0 100 071 090 Red 0 Green 100 0 Blue 100 091 110 Red 0 100...

Page 9: ...peed CH12 ID address setting 000 009 ID1 ID66 010 019 ID1 020 029 ID2 030 039 ID3 200 209 ID20 210 ID21 211 ID22 255 ID66 ARC 1 3 Channels Mode Function Function Control CH1 Red 000 255 0 100 Red dimm...

Page 10: ...00 White dimmer CH6 Strobe 000 255 Strobe with speed increasing HSV 3 Channels Mode Function Function Control CH1 Hue 000 255 0 100 Hue CH2 Saturation 000 255 0 100 Saturation CH3 Value brightness 000...

Page 11: ...dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solut...

Page 12: ...nt temperature control Silent operation PMMA polymethyl methacrylate lens Barn doors included Control protocols DMX RDM Control channels ARC 1 3CH AR1 D 4CH ARC 2 4CH AR2 D 5CH AR2 S 6CH HSV 3CH STAG...