8
Version 1.0
The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting
existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and
receive messages from specific fixtures.
With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful
when the device is installed in a remote area.
Each FR-150C has a factory set RDM UID (unique identification number).
Zoom
Step 1: Loosen the zoom button on the top of the device, toward the back.
Step 2: Adjust the zoom by sliding the zoom button forward or backward.
Step 3: Tighten the zoom button.
DMX Protocol
1 Channels Mode
Function
Function Control
CH1
Dimmer
000-255: 0-100% dimmer
2 Channels Mode
Function
Function Control
CH1
Dimmer
000-255: 0-100% dimmer
CH2
Strobe
000-255: strobe with speed increasing
3 Channels Mode
Function
Function Control
CH1
Dimmer
000-255: 0-100% dimmer
CH2
Strobe
000-255: strobe with speed increasing
CH3
Dimmer mode
000-050:
Dimmer speed 0 (no delay)
051-100:
Dimmer speed 1
101-150:
Dimmer speed 2
151-200:
Dimmer speed 3
201-255:
Dimmer speed 4 (slowest speed)
4 Channels Mode
Function
Function Control
CH1
Dimmer
000-255: 0-100% dimmer
CH2
Strobe
000-255: strobe with speed increasing
CH3
Dimmer mode
000-050:
Dimmer speed 0 (no delay)
051-100:
Dimmer speed 1
101-150:
Dimmer speed 2
151-200:
Dimmer speed 3
201-255:
Dimmer speed 4 (slowest speed)