If the device has been exposed to temperature changes due to environmental changes, do not switch 
it on immediately. The arising condensation could damage the device. Leave the device switched off 
until it has reached room temperature. 
 
This device falls under protection-class I. Therefore it is essential that the device be earthed. 
The electric connection must carry out by qualified person. 
 
The device shall only be used with rate voltage and frequency.

 

Make sure that the available voltage is not higher than stated at the end of this manual. 
 
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, 
replacement of the cable must be done by an authorized dealer. 
 
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 
 
During initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective, it should decrease gradually. 
Please don't project the beam onto combustible substances. 

 

Fixtures cannot be installed on combustible substances, keep more than 50cm distance with wall for 
smooth air flow, so there should be no shelter for fans and ventilation for heat radiation. 

 

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by 
the manufacturer or his service agent or a similar qualified person in order to avoid a hazard. 
 

N ev er   look    direc tl y    into   the   light   source,   

as   sensitiv e   persons   m ay    suffer   an   epileptic   shock .   

N ev er   touc h   the   dev ic e   during   operation!   

T he   housing   m ay    heat   up   

 

Please be aware that damages caused by manual modifications to the device are not subject to 
warranty. Keep away from children and non-professionals. 
 

GENERAL GUIDELINES 

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc. 
This fixture is only allowed to be operated with the max alternating current which stated in the 
technical specifications in the last page of this manual, the device was designed for indoor use only. 
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure 
that the device will serve you for a long time without defects. Do not shake the device. 
Avoid brute force when installing or operating the device. 

Summary of Contents for CL 575S-E

Page 1: ...PROFESSIONAL MOVING HEAD USER MANUAL CL 575S E KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...sound activated via built in microphone Pan and tilt movement 8 and 16 bit resolution For smooth and precise motion Movement Pan 540 630 optional Tilt 260 Speed of pan tilt movement adjustable Scan p...

Page 3: ...tion it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual 1 Projector head 2 Objective lens 3 Yoke 4 Ventilation fan 5 Base 6 Control...

Page 4: ...onto combustible substances Fixtures cannot be installed on combustible substances keep more than 50cm distance with wall for smooth air flow so there should be no shelter for fans and ventilation for...

Page 5: ...result of unprofessional operation Please use the original packaging if the device is to be transported For safety reasons please be aware that all modifications on the device are forbidden If this de...

Page 6: ...below 1 3 2 A B C D Please remember the lamp is not a hot restrike type you must wait for approximately 15 minutes after having turned off the lamp before you can turn it back on again D o not operat...

Page 7: ...le m aterial w ithin a distance of min 0 5m Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safet...

Page 8: ...Pull the safety rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw DMX 512 control connec...

Page 9: ...channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct nu...

Page 10: ...e Fixture running time Lamp running time Lamp off time Clear lamp time Temperature Info Base Temperature Head Temperature XX XXX Temperature on the display board of the base Temperature in the head So...

Page 11: ...m Select Programs Auto Pro Part 1 Auto Pro Part 2 Auto Pro Part 3 Program 1 10 Program 1 Program 1 10 Program 2 Program 1 10 Program 3 Select programs to be run Edit Program Program 1 Program 10 Progr...

Page 12: ...ff Clear lamp time With this function you can clear the running time of the lamp Please clear the lamp time every time you replace the lamp Select Clear lamp time by turning the encoder Press the enco...

Page 13: ...r DMX 16 channel of internal program value 60 79 Select ON by turning the encoder if you wish to enable this function or OFF if you don t Lamp Off if no DMX With this function you can select to switch...

Page 14: ...ement or tilt movement Pan Degree With this function you can select pan degree for 630 or 540 Dimmer Speed With this function you can adjust the dimming speed Feedback With this function you can feedb...

Page 15: ...erent channels list by different sequence For example after the user enter this manual if select Auto Program CH 16 means in this User s mode the Dimmer is in Channel 12 User mode With this function y...

Page 16: ...rn to the main menu 3 Program selection for Auto Pro Part Select Edit program by turning the encoder Press the Enter button to confirm Select Select programs by turning the encoder Press the Enter but...

Page 17: ...s Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture INSTRUCTIONS ON USE DMX channel...

Page 18: ...5 shake slow to fast 170 189 Gobo 6 shake slow to fast 190 255 Rot gobo wheel cont rotation slow to fast Channel 3 Rotating gobo index rotating gobo rotation 0 127 Gobo indexing 128 189 Forwards gobo...

Page 19: ...prism Prism Gobo macros 0 3 open 4 63 Forwards rotation from fast to slow 64 67 No rotation 68 127 Backwards rotation from slow to fast 128 135 Macro 1 136 143 Macro 2 144 151 Macro 3 152 159 Macro 4...

Page 20: ...l 13 Iris 0 191 Max diameter to Min diameter 192 223 Pulse opening fast to slow 224 255 Pulse closing slow to fast Channel 14 Frost 0 191 Frost 0 100 192 223 Pulse opening fast to slow 224 254 Pulse c...

Page 21: ...1 If there are some errors on channel 1 channel 5 channel 6 at the same time you may see the error message Color Er PAN movement 8bit Er TILT movement 8bit Er flash repeated for 5 times and then the...

Page 22: ...or is defective or its driver circuit on the main PCB The color wheel 2 is not located in the default position after the reset Prism Er Prism error This message will appear after the reset of the fixt...

Page 23: ...FICATIONS Power supply 100VAC 50Hz 120VAC 50Hz 208VAC 50Hz 220VAC 50Hz 230VAC 50Hz 240VAC 50Hz 100VAC 60Hz 120VAC 60Hz 208VAC 60Hz 220VAC 60Hz 230VAC 60Hz 240VAC 60Hz Power consumption max 780W Lamp M...

Reviews: