10
Cyclone Insert Installation - English
Install the BX2000/BX2010 Hood
1. Place the top of the range hood against the bottom of the
cabinet. Route the power supply cord through the access hole
and through the knockout. This step
will have to be accomplished while
positioning the hood (Figure 5 & 6).
2. Center the hood in place beneath the
cabinet
and
align
with
the
front
of
the cabinet.
Outline
the
four
keyhole
mounting slots for the hood onto the
bottom of the cabinet.
3. Partially screw in the four hood
mounting wood screws through the
narrow ends of the marked keyholes.
4. Align the hood’s wider ends of the
keyholes mounting slots over the four partially installed
screws. Push the hood against the wall so that the screws are
now secured in the narrow end of the keyhole and that the
front of the hood is aligned with the cabinet front (Figure 6).
5. Check to ensure the top vent is fitted and connected to the
duct properly. Use aluminum foil tape to cover all seams.
6. Tighten the hood mounting screws all the way into the cabinet
so the hood is firmly attached.
7. Make the Electrical Connection (Figure 7).
i. Secure the electrical wire to the hood with the connector’s
“STAR” locknut.
ii. Strip about ½” of insulation from the ends of the electrical
power wires.
iii. Connect the power line ground wire to the green ground
wire supplied with the hood (Figure 8).
iv. Connect the black power wire to the black wire supplied
with the hood.
v. Connect the white neutral wire to the white wire supplied
with the hood.
Knockout
Opening
Mounted Strips
Width of
Range Hood
Keyhole
Slot Outline
8. Reinstall the hood cover plate with the insert screws. Attach the
rectangular and round oil collectors at the far back and under
the mesh respectively.
9. Turn on the hood to check for any leaks in the ductwork and
to ensure proper function.
Figure 5.
Figure 6.
Figure 8.
Junction Box
Range Hood Connection
Power Line Connection
Range Hood Front
Electrical Knockout
Figure 7.
Green: Ground
White: Neutral
Black: Power