2400-31

FRONT END PROCESSOR 

MAINTENANCE & 

SUPPORT GUIDE

Summary of Contents for 2400-31

Page 1: ...nges to any products herein to improve reliability function or design Cyclone Microsystems Inc neither assumes any liability arising out of the application or use of any product or circuit described h...

Page 2: ...Connector 2 7 2 3 4 E1 Connectors 2 8 CHAPTER 3 3 1 FEP INITIALIZATION AND BUILT IN SELF TEST 3 1 CHAPTER 4 4 1 PERIODIC MAINTENANCE 4 1 CHAPTER 5 5 1 SERVICEABLE COMPONENTS 5 1 5 2 BOARD REMOVAL AND...

Page 3: ...31 FEP Maintenance Support Guide Revision 1 0 March 2005 7 4 EFFECTIVE PERIOD OF WARRANTY 7 1 7 5 REPAIRED OR REPLACEMENT PRODUCT OUT OF WARRANTY 7 1 7 6 SERVICE POLICY 7 2 APPENDIX A A 1 ADDITIONAL...

Page 4: ...EP Part Numbering 1 1 Figure 2 1 600 2400 31 D0 FEP Front Panel 2 1 Figure 2 2 600 2400 31 A0 FEP Front Panel 2 2 Figure 2 3 600 2400 31 FEP Front Panel LEDs 2 3 Figure 2 4 DC Power Connector 2 5 Figu...

Page 5: ...00 31 FEP Front Panel LED Description 2 3 Table 2 4 Ring Lugs for 10 Studs 2 6 Table 2 5 Console Port Connector 2 7 Table 2 6 Ethernet Port Connector 2 7 Table 2 7 E1 ATM Port 0 Connector Pin Assignme...

Page 6: ...lso monitors power supply fan status and temperature in an effort to detect and provide early alert to component failures The part numbering system for the 600 2400 series of FEPs is as shown in Figur...

Page 7: ...rsuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment gen...

Page 8: ...ower Connector B 4 FEP Power supply ON OFF Switch B 5 FEP Reset Switch 6 FEP Ground Lugs 7 CPCI 821 8 CPCI 817 1 9 CPCI 817 2 10 Power Supply A 11 Power Supply B 12 Fan Filter Assembly FRONT END PROCE...

Page 9: ...21 FN1 Turns on and remains on for FAN1 good condition and turns off for FAN1 failure 5 0 CPCI 821 LPX Turns on and remains on for local PCI bus running PCI X and turns off for local PCI bus not runni...

Page 10: ...ink integrity for Ethernet port 1 and will remain on continuously if port 1 is connected to a functional network or Ethernet port 15 CPCI 817 ST0 Indicates status 0 for CPCI 817 and will light for a s...

Page 11: ...CTORS 2 3 1 Power Connector There are two power supply connectors on the right hand side of the FEP 2 3 1 1 DC Power Connectors 600 2400 31 D0 The DC power connector is military style circular bayonet...

Page 12: ...ceptacle Figure 2 5 AC Power Connector 2 3 1 3 Ground Studs There are two 10 32 threaded studs with hex nuts flat washers and star washers included attached to the chassis of the 600 2400 31 A0 and 60...

Page 13: ...821 console connector A cable connecting the console port to a standard DB25 connector is available from Cyclone Microsystems P N 530 2006 A terminal or PC running a terminal emulation program should...

Page 14: ...he connector is not connected to chassis ground The shield of the connector is RING and the center conductor is TIP Figure 2 6 75ohm BNC Connector Table 2 7 E1 ATM Port 0 Connector Pin Assignments Tab...

Page 15: ...will indicate the last successfully completed stage of the board initialization sequence The following table describes the startup LEDs Table 3 1 CPCI 817 Initialization and Self Test LEDs User LED Pa...

Page 16: ...Passed ACT External Bus Controller Initialized ST0 Local Bus Priorities Set ST1 Interrupt Controller Initialized IOP UART Initialized ACT ST0 Reset Status Check Done ACT ST1 I2C Bus Initialized ACT IO...

Page 17: ...er supplies The fan and air filter assembly is located on the left hand side of the FEP unit Replacement filters can be purchased from Cyclone Microsystems Cyclone part number 370 1303 Table 4 1 Air F...

Page 18: ...y handled with a ground strap and transported in an ESD shielded bag Turn power off Disconnect cables from the board Loosen the two retaining screws on the boards front panel The retaining screws are...

Page 19: ...Filter Assembly Installation Align the flanges in the Fan Filter assembly with its guides after replacing the fan and slide the Fan Filter access panel into the unit 5 4 POWER SUPPLY REMOVAL AND INST...

Page 20: ...ailures per billion hours Mean Time Between Failures MTBF is the inverse of the failure rate and is the average time between failures 6 2 ASSUMPTIONS Ambient input air temperature does not exceed 30 d...

Page 21: ...17 CM817 064 T 2 3028 330 250 DC Power Supply 2400 Chassis 370 1301 1 2172 460 405 Fan Filter Assembly 2400 Chassis 370 1300 1 100 6914 144 634 600 2400 31 A0 1 CPCI 821 CM821 064 00 T3 1 1614 619 409...

Page 22: ...r repair without charge any defective component of such products 7 3 SOFTWARE AND FIRMWARE Cyclone warrants that Software and Firmware supplied shall conform to the then current published documentatio...

Page 23: ...r incidental or consequential damages of any kind arising out of the sale installation or use of its products 7 6 SERVICE POLICY Out of repair warranty will be accomplished expeditiously at a charge p...

Page 24: ...ALS A 1 ADDITIONAL INFORMATION Additional information for each of the boards used in the FEP can be found in their respective User s Manual These manuals are available from Cyclone Microsystems Part N...