Cycle Stop Valves CSV1A Installation Instructions Download Page 2

Symptom

Cause

Diaphragm is worn out

Remedy

This is usually due to differential
pressure being higher than 125 PSI.
Use a second valve to reduce differen-
tial pressure to original valve. Replace
diaphragm in original valve.

Pump is Cycling off and on

Waterlogged pressure tank

Replace tank

Bad or torn diaphragm

Replace pilot diaphragm

Low pressure

Valve is not set correctly

Reset valve

Demand is more than pump can provide
at desired pressure

Reduce demand so it is within pump
capabilities to maintain desired
pressure.

Chattering valve

Too much air pressure in tank

Reduce air pressure in tank to 5-10
PSI below cut in pressure.

Pump rapid cycles at
start up and
then begins to function
correctly

Pressure switch is located on the main
line or closer to the main line than the
pressure tank.

Move pressure switch to small line at
the base of the tank on a line no
larger than 1 1/4” in diameter

CSV setting is too close to cut off
pressure

Set pressure switch cut off pressure
at least 10 PSI higher than CSV
setting

Air pressure in tank too high

Reduce air pressure in tank to 5-10
PSI  below cut in pressure

Multiple check valves in system work-
ing against each other

Remove all but the check valve or foot
valve on the pump itself

CSV1A Troubleshooting

Pressure switch or valve not set
correctly

Cut off pressure must be higher than
valve pressure.  Reset pressure switch
or valve.