Cyberstat CY1201 User Manual Download Page 10

 

H

ea
t P
um
p

 

10 

 
Wiring option 2 for Heat Pump 

 

Use this wiring option to re-purpose green wire as C wire 

 

Re-purposing requires some wiring changes on the 

air-handler

 side 

 

With this option, you will not be able to use fan independently 

 
Air-handler  wiring  
to re-purpose green 
wire as C wire 
 
1. Move green wire 
to C terminal and 
2.  Put  a  jumper 
across  Y  and  G 
terminals 

24 V AC neutral (C wire) 
24 V AC hot 
Reversing Valve 
Compressor 


O/B 

Air-Handler 

CyberStat 

C

 

R

 

O

/B/

W

Y

 

G

 

W2

 

Aux Heat 

Aux 

Summary of Contents for CY1201

Page 1: ...Motison CyberStat CY1201 Due to continuous improvement some features and appearance may have changed User s Manual...

Page 2: ...unc tion was caused by damage which occurred while the product was in the possession of a consumer Motison s sole responsibility shall be to repair or replace the product within the terms stated above...

Page 3: ...and Conventional systems2 3 Heat pump with auxiliary heat 1 cooling and 2 heating stages Conventional system 1 cooling and 1 heating stages Maximum control current 400 mA any terminal Temperature acc...

Page 4: ...the terminal names and corresponding wire colors below Depending on your system you may not have all the wires listed here 5 Now remove the wires and the old wall plate Old Thermostat Terminal Wire Co...

Page 5: ...f the old thermostat did not use drywall anchors then most likely there is a wood bracing behind the drywall In that case you should skip this step Tip The drywall anchor does not require pre drilling...

Page 6: ...re is not required for a cool only system Notes on C wire Make sure that C wire is connected to C terminal on the furnace You will not get stable power if C wire is not connected to C terminal on the...

Page 7: ...purposing requires some wiring changes on the furnace side With this option you will not be able to use fan independently Furnace side wiring to re purpose green wire as C wire 1 Move green wire to C...

Page 8: ...u do not have a C wire Yellow and green wires are not required for a heat only system White wire is not required for a cool only system 24 V AC adapter is required if you do not have a C wire If using...

Page 9: ...terminal names Notes on C wire Make sure that C wire is connected to C terminal on the air handler You will not get stable power if C wire is not connected to C terminal on the air handler A previousl...

Page 10: ...on the air handler side With this option you will not be able to use fan independently Air handler wiring to re purpose green wire as C wire 1 Move green wire to C terminal and 2 Put a jumper across Y...

Page 11: ...f you do not have a C wire Use Elk TRG2440 or similar transformer 24 V AC adapter is required if you do not have a C wire If using an external power supply you will have two wires going to R terminal...

Page 12: ...g 12 Wiring two wire heat only system Use Elk TRG2440 or similar transformer 24 V AC adapter is required with a two wire heating system You will have two wires going to R terminal 24 V AC hot Heat C R...

Page 13: ...ted 24 V AC transformer will not interfere with Milli Volt system Use Elk TRG2440 or similar transformer Milli Volt Wire 1 Milli Volt Wire 2 C R O B W1 Y G W2 24 V AC adapter is required with a Milli...

Page 14: ...ow the terminal level 6 Attach the front assembly to the wall plate First hook the tabs on the top of front assembly to the slots on the wall plate then snap the bottom in place 7 Turn on the power to...

Page 15: ...connections A wrong connection can still produce a false positive 2 If you had opened your furnace or air handler panel be sure to close it Often there is a switch on the panel cover This switch cuts...

Page 16: ...d move on to the next item For conventional systems there is only one configuration item to fill in For these systems pressing mode button will bring back the normal display immediately Use the config...

Page 17: ...for heating pick 0 For most other brands reversing valve is energized for cooling pick 1 To verify your settings run a cooling test described on the next page Heating test is not suitable for this pu...

Page 18: ...oom temperature The air conditioner should turn on Heating test Press the mode button repeatedly until the heat light comes on Press up or down buttons to select a temperature higher than the room tem...

Page 19: ...le after you setup Wi Fi Auto CyberStat automatically sets heating or cooling modes to maintain set temperature Heat If the room temperature goes below set temperature then the heater is turned on Fan...

Page 20: ...on New program will be effective at next scheduled point Overrides Press up or down buttons to change set temperature The settings indicator turns on when the display shows set temperature Press mode...

Page 21: ...ill attached to Cyber Stat access point 4 On the setup page select your Wi Fi network and enter your wireless network s password 5 When Wi Fi indicator is solid green click on the Activate My Device b...

Page 22: ...To add webapp to your home screen Logon to thermostat motison com and check the remember me box then follow steps below specific to your device Apple devices 1 Click on the arrow icon and select Add...

Page 23: ......

Page 24: ...designed for a do it yourself project Give it a try If you ever have any problems during installation or use please do not hesitate to contact us We are here to help Help and Support Email support mot...

Reviews: