background image

CPEX Series   

 

 

CyberResearch

® 

CPU Cards 

 

28  

©Copyright 2005 

CyberResearch, Inc.

 

 
 

Allow you to enable or disable the floppy disk controller. 
Configuration options: [Disabled] [Enabled]

   

Floppy Drive Swap [Disabled]

 

Configuration options: [Disabled] [Enabled] 

Serial Port1 Address [3F8/IRQ4] 

Allow you to select the Serial Port1 base address. 

Configuration options: [Disabled] [3F8/IRQ4] [3E8/IRQ4] [2E8/IRQ3] 

Serial Port2 Address [2F8/IRQ3] 

Allow you to select the Serial Port2 base address. 
Configuration options: [Disabled] [2F8/IRQ3] [3E8/IRQ4] [2E8/IRQ3] 

Parallel Port Address [378] 

Allow you to select the Parallel Port base addresses. 
Configuration options: [Disabled] [378] [278] [3BC] 

Parallel Port Mode [Normal] 

Allow you to select the Parallel Port mode. 

Configuration options: [Normal] [Bi-directional] [EPP] [ECP] 

Parallel Port IRQ [IRQ7] 

Configuration options: [IRQ5] [IRQ7] 

 

 

 

3.7.5    Hardware Health Configuration 

This screen shows you the CPU, System and Power temperature, Fan speed and 
CPU core voltage. It also allows your to configure the Hardware Health Monitoring. 

H/W Health Function [Enabled]

 

To enable/disable H/W Health function 

FAN1 Mode Setting [Full On Mode]

 

To configure Fan mode as Full On, Automatic or PWM Manually mode.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.7.6  ACPI Configuration 

This menu is used to change the settings for the Advanced Power Management 
(APM). Select an item then press Enter to display the configuration options. 

 

 

Summary of Contents for CPEX CEL-24-X

Page 1: ...2 4GHz Celeron CPU VGA SATA USB GB LAN Audio CPEX P4 24 X PICMG Single Board Computer with 2 4GHz Pentium 4 CPU VGA SATA USB GB LAN Audio CPEX P4 32 X PICMG Single Board Computer with 3 2GHz Pentium...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...erResearch and CPEX series are trademarks of CyberResearch Inc Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of thei...

Page 6: ...CPEX Series CyberResearch CPU Cards iv Copyright 2005 CyberResearch Inc Intentionally Blank...

Page 7: ...CyberResearch CPU Cards CPEX Series CyberResearch Inc v 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com...

Page 8: ...CPEX Series CyberResearch CPU Cards vi Copyright 2005 CyberResearch Inc...

Page 9: ...ard Computer X1 2 RS 232 Printer Cable with bracket X1 3 ATA IDE cable X1 4 SATA IDE cable X2 5 SATA Power cord cable X1 6 ATX 12V cable X1 7 Keyboard and mouse Y Adapter cable X1 8 Mini Jumper Pack X...

Page 10: ...nector FDD 12 2 3 Parallel Port LPT 13 2 4 Serial Ports COM1 COM2 13 2 5 IrDA Infrared Interface Port IR 14 2 6 DVI Connector DVI 15 2 7 USB Port Connectors USB1 USB2 USB3 USB4 15 2 8 Keyboard Mouse C...

Page 11: ...on 31 3 8 PCI PnP 32 3 9 Boot 33 3 10 Security 35 3 11 Chipset 36 3 11 1 North Bridge Configuration 36 3 11 2 South Bridge Configuration 37 3 12 Power 38 3 13 Exit 39 Chapter 4 Chipset Software Instal...

Page 12: ...yboard Mouse Connector 60 B 11 Fan Connector 60 B 12 Serial ATA Connector 61 B 13 External Switches and Indicators 61 B 14 AC 97 Connector 62 B 15 VGA Connector 62 B 16 ATX _12V Power Connector 63 B 1...

Page 13: ...bit color at 85 Hz CPEX series supports one or two 64 bit wide DDR400 data channels Available bandwidth is up to 3 2GB s in single channel mode and 6 4GB s in dual channel mode The single chip PCI Ex...

Page 14: ...y is up to 2 GB Installing two identical DIMMs in pairs will result in Dual Channel operations which theoretically will double the memory bandwidth z Enhanced IDE interface Supports up to 2 PCI Enhanc...

Page 15: ...with LED on rear I O panel Multi I O Ports z Chipset Intel ICH6 with ITE IT8712F Super I O controller z Serial ports Two RS 232 ports by pin header Ports can be individually configured to COM1 COM2 o...

Page 16: ...t power supply or higher is recommended z Power control function meets ACPI 1 1 specification z Operating Temperature 0 60 CPU needs Cooler silicone heat sink paste z Relative Humidity 5 95 non conden...

Page 17: ...in unshrouded header USB4 USB dual port connector 8 pin unshrouded header LAN LAN RJ45 connector RJ 45 with LED KB MS 6 pin Mini Din Keyboard Mouse connector PS 2 fixed rear panel mount KB External 5...

Page 18: ...CPEX Series CyberResearch CPU Cards 6 Copyright 2005 CyberResearch Inc 1 5 Board Layout Jumper and Connector Locations...

Page 19: ...Intel Socket 478 Pentium 4 Supporting HT Technology Intel 915GV GMCH Intel ICH 6 PCI SLOT PCI EXPRESS GIGA LAN WINBOND Clock Generator SDVO DVI 8 Hi Speed USB 2 0 CHANNEL A DDR SDRAM DIMM X 1 IDE PRI...

Page 20: ...ving the plastic clip from the jumper Note The default jumper setting is marked in GREY color 1 7 2 CMOS clear CLR_CMOS In case CPEX series fails to boot due to user s improper BIOS setting CLR_CMOS j...

Page 21: ...modules are used This means installing two identical DIMMs results in dual channel operation mode which will double the memory bandwidth to 6 4GB s To install memory module first make sure the two han...

Page 22: ...he built in second level cache in the processor yields much higher performance than the external cache memories The cache size in the Intel Pentium 4 processor 3 0GHz for example is 1024 KB 1 10 Proce...

Page 23: ...CyberResearch CPU Cards CPEX Series CyberResearch Inc 11 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com Step 3 Lower the lever to its original position...

Page 24: ...nce IDE1 IDE Interface Connector 2 2 Floppy Disk Drive Connector FDD You can attach up to two floppy disk drives to the CPEX series onboard controller You can use 3 5 360KB 720KB 1 2MB 1 44MB and 2 88...

Page 25: ...ected to the parallel port The CPEX series includes an on board parallel port accessed via a 26 pin flat cable connector LPT LPT1 Parallel Port Connector 2 4 Serial Ports COM1 COM2 The CPEX series off...

Page 26: ...2 Serial Port Connector 2 5 IrDA Infrared Interface Port IR The product has a built in IrDA port which supports Serial Infrared SIR or Amplitude Shift Keyed IR ASKIR interface If you want to use the I...

Page 27: ...r DVI display 2 7 USB Port Connectors USB1 USB2 USB3 USB4 The CPEX series provides up to four USB Universal Serial Bus ports which gives complete Plug Play and hot swapping for up to 127 external devi...

Page 28: ...respectively KB MS1 6 pin Mini DIN Keyboard Connector 1 3 5 2 4 6 2 9 Fan Connectors CPU_FAN PWR_FAN The CPEX series also has a CPU with cooling fan connector and chassis fan connector which can supp...

Page 29: ...data transfer rate up to 150MB s Serial ATA also provides Hot Plug support lower pin count lower signaling voltage easier cabling and CRC Error Detection Please refer to the BIOS setting for the Seria...

Page 30: ...00Mbps LAN2 Ethernet controllers You can connect it to your LAN through RJ45 LAN connectors There are two LED on the connector CN2 CN3 indicating the status of LAN 2 13 AC 97 Connector J_AUDIO1 The au...

Page 31: ...rd CT USA www cyberresearch com 2 14 VGA Connector VGA The CPEX series includes a VGA interface that can drive conventional CRT displays It is a standard 15 pin D SUB connector commonly used for VGA V...

Page 32: ...X_12V power connector mainly supplies power to the CPU If the ATX_12V power connector is not connected the system will not start This connector supports the ATX 12V power 2 17 ATXCTL Connector ATXCTL...

Page 33: ...can be activated in one of two ways 1 By pressing Del immediately after switching the system on or 2 by pressing the Del key when the following message appears briefly at the bottom of the screen duri...

Page 34: ...le to boot the AMI BIOS supports an override to the CMOS settings that resets your system to its defaults The best advice is to only alter settings that you thoroughly understand To this end we strong...

Page 35: ...cted system memory System Time HH MM SS It shows the current time You may set the time according to your local time System Date Day MM DD YYYY This item allows you to set the system date 3 7 Advanced...

Page 36: ...nformation which is detected by BIOS User may set the CPU operating speed with following options Max CPUID Value Limit Disabled Enable this item to boot legacy Operating System that cannot support CPU...

Page 37: ...rocessor supporting Hyper Threading Technology presents itself to modern operating systems and applications as two virtual processors The processor can work on two sets of tasks simultaneously use res...

Page 38: ...controller As PIO mode increases the cycle time decreases Select Auto to let AMIBIOS select the PIO mode If you select a specific value for the PIO mode you must be absolutely sure that the value you...

Page 39: ...A 1 44 MB 3 Select the type of floppy drive connected to CPEX series Configuration options Disabled 360K 5 25 1 2M 5 25 720K 3 5 1 44M 3 5 2 88M 3 5 Floppy B Disabled Select the type of floppy drive c...

Page 40: ...lel Port base addresses Configuration options Disabled 378 278 3BC Parallel Port Mode Normal Allow you to select the Parallel Port mode Configuration options Normal Bi directional EPP ECP Parallel Por...

Page 41: ...pointers to 64 bit Fixed System Description Tables Configuration options No Yes ACPI APIC support Enabled This menu allows you to enable or disable the ACPI support in the ASIC When set to Enabled the...

Page 42: ...Remote Access Configuration This menu allows you to enable or disable Remote Access Configuration options Disabled Enabled If you choose Enable below sub menus will show up Serial port number COM1 Th...

Page 43: ...sable Boot Loader Always Terminal Type ANSI This menu allows you to select the target terminal type Configuration options ANSI VT100 VT UTF8 VT UTF8 Combo Key Support Disabled This menu allows you to...

Page 44: ...atency Timer 64 This menu allows you to select the value in units of PCI clocks for the PCI device latency timer register Configuration options 32 64 96 128 160 192 224 248 Allocate IRQ to PCI VGA Yes...

Page 45: ...vices Configuration options Available Reserved DMA Channel Available When set to Available the specified DMA is available for use by PCI PnP devices When set to Reserved the specified DMA is reserved...

Page 46: ...its for F1 key to be pressed when error occurs Configuration options Disabled Enabled Hit DEL Message Display Enabled When set to Enabled the system displays the message Press DEL to run Setup during...

Page 47: ...ows the default Not Installed After you have set a password this item shows Installed Change User Password Select this item to set or change the user password The User Password item on top of the scre...

Page 48: ...3MHz 400MHz Configure DRAM Timing by SPD Enabled When this item is enabled the DRAM timing parameters are set according to the DRAM SPD Serial Presence Detect When disabled you can manually set the DR...

Page 49: ...ow you to select the boot display device Configuration options CRT EFP CRT EFP 3 11 2 South Bridge Configuration Azalia AC 97 Selection Enable Allow you to enable or disable the AC 97 Audio Configurat...

Page 50: ...system goes on standby Configuration options Disabled 1 Min 2 Min 4 Min 8 Min 10 Min 20 Min 30 Min 40 Min 50 Min 60 Min Suspend Time Out Disabled Allow you to select the specified time at which the s...

Page 51: ...off When you select this option a confirmation window appears Select Yes to save changes and exit Discard Changes and Exit Select this option only if you do not want to save the changes that you made...

Page 52: ...ortant to note that most display drivers need to have the relevant software application already installed in the system prior to installing the enhanced display drivers In addition many of the install...

Page 53: ...ows 98SE Windows 2000 Windows Me Windows XP 4 3 Windows XP Driver Setup 1 Insert the driver CD into your system s CD ROM drive In a few seconds the software installation main menu appears Move the mou...

Page 54: ...es CyberResearch CPU Cards 42 Copyright 2005 CyberResearch Inc 4 Click Next when you see the following message 5 When the following message appears click Finish to complete the installation and restar...

Page 55: ...ogy integrated into the chipset z Flexible memory support for both dual channels DDR2 533 memory which can deliver up to 8 5 GB s bandwidth 5 2 Windows XP Driver Setup Note Before installing this driv...

Page 56: ...CPEX Series CyberResearch CPU Cards 44 Copyright 2005 CyberResearch Inc 2 Click Yes when you see the following message 3 Click Finish to complete the installation and restart the computer now or later...

Page 57: ...ort for commonly used network systems is also provided 6 2 Windows XP Driver Setup Note Before installing the LAN drivers make sure the CSI utility has been installed in your system See Chapter 4 for...

Page 58: ...CPEX Series CyberResearch CPU Cards 46 Copyright 2005 CyberResearch Inc 3 In Device Manager choose Ethernet Controller and then double click 4 Choose the option Driver and then click on Update Driver...

Page 59: ...25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com 5 In Hardware Update Wizard choose Install from a list or specific location Advanced and then click on Next 6...

Page 60: ...CPEX Series CyberResearch CPU Cards 48 Copyright 2005 CyberResearch Inc 7 In the following window please click on Finish to complete USB driver installation...

Page 61: ...peed demanding I O peripherals z Provides data transmission rate up to 480Mb s z Offer 40 greater bandwidth than USB 1 1 z Offers complete compatibility with current USB device 7 2 Installation Note B...

Page 62: ...CPEX Series CyberResearch CPU Cards 50 Copyright 2005 CyberResearch Inc 3 In Device Manager choose USB Controller and then double click 4 Choose the option Driver and then click on Update Driver...

Page 63: ...25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com 5 In Hardware Update Wizard choose Install from a list or specific location Advanced and then click on Next 6...

Page 64: ...CPU Cards 52 Copyright 2005 CyberResearch Inc 7 In the following windows please specify the location D USB20 Intel WinXP and then click on OK 8 In the following window please click on Finish to comple...

Page 65: ...he Watchdog Timer s period BL Time out value Its unit second is dependent on the item Watchdog Timer unit select in CMOS setup You have to call sub function 2 to set the time out period of Watchdog Ti...

Page 66: ...rch Inc MOV AX 6F02H setting the time out value MOV BL 30 time out value is 48 seconds INT 15H ADD YOUR APPLICATION PROGRAM HERE CMP EXIT_AP 1 is your application over JNE W_LOOP No restart your appli...

Page 67: ...IDE Connector PIN DESCRIPTION PIN DESCRIPTION 1 RESET 2 GND 3 DATA 7 4 DATA 8 5 DATA 6 6 DATA 9 7 DATA 5 8 DATA 10 9 DATA 4 10 DATA 11 11 DATA 3 12 DATA 12 13 DATA 2 14 DATA 13 15 DATA 1 16 DATA 14 1...

Page 68: ...DIR 19 GND 20 STEP 21 GND 22 WD 23 GND 24 WGATE 25 GND 26 TRK0 27 GND 28 WP 29 GND 30 RDATA 31 GND 32 HEAD 33 GND 34 DSKCHG B 3 Parallel Port Connector LPT Parallel Port Connector PIN DESCRIPTION PIN...

Page 69: ...6 DATA SET READY DSR 7 REQUEST TO SEND RTS 8 CLEAR TO SEND CTS 9 RING INDICATOR RI 10 GND B 5 Compact Flash Storage Card Socket CF Compact Flash Storage Card Socket pin assignment PIN DESCRIPTION PIN...

Page 70: ...Infrared Interface Port IR IrDA connector PIN DESCRIPTION 1 VCC 2 NC 3 IR RX 4 GND 5 IR TX B 7 DVI Connector DVI DVI Connector PIN DESCRIPTION PIN DESCRIPTION 1 DATA2 14 VCC 2 DATA2 15 NC 3 GND 16 HP_...

Page 71: ...CRIPTION 1 VCC 2 GND 3 DATA0 4 DATA1 5 DATA0 6 DATA1 7 GND 8 VCC B 9 LAN Connector CN2 LAN1 State LED Connector PIN DESCRIPTION PIN DESCRIPTION 1 SPEED 2 SPEED 3 LINK 4 ACT LAN2 100 1000 LAN RJ45 Conn...

Page 72: ...DIN Keyboard Mouse Connector PIN DESCRIPTION 1 KEYBOARD DATA 2 MOUSE DATA 3 GND 4 5V 5 KEYBOARD CLOCK 6 MOUSE CLOCK KB 5 pin Header Keyboard Connector PIN DESCRIPTION 1 KEYBOARD CLOCK 2 KEYBOARD DATA...

Page 73: ...2 Serial ATA Connector S_ATA1 S_ATA2 S_ATA3 S_ATA4 Serial ATA Connector PIN DESCRIPTION 1 GND 2 S_TXP 3 S_TXN 4 GND 5 S_RXP 6 S_RXN 7 GND B 13 External Switches and Indicators PIN DESCRIPTION PIN DESC...

Page 74: ...PCBEEP 5 SDIN 6 RST 7 VCC 8 GND 9 12V 10 GND 9 7 5 3 1 10 8 6 4 2 The product does not has a built in AC 97 AUDIO CODEC It needs to connect to the AUDIO CODEC module B 15 VGA Connector VGA 15 pin Fem...

Page 75: ...d CT USA www cyberresearch com B 16 ATX _12V Power Connector PW ATX_12V Power Connector PIN DESCRIPTION PIN DESCRIPTION 1 GND 2 GND 3 12V 4 12V B 17 ATXCTL Connector ATXCTL Backplane to Mainboard Conn...

Page 76: ...1 Interrupt Controller 0C0 0DF DMA Controller 0F0 0FF Numeric data processor 1F0 1F7 Primary IDE Channel 2F8 2FF Serial Port 2 COM2 378 37F Parallel Printer Port 1 LPT1 3B0 3BB Intel R 82915 Graphics...

Page 77: ...8 RTC clock IRQ1 Keyboard IRQ9 ACPI IRQ2 Available IRQ10 LAN IRQ3 COM2 IRQ11 LAN USB2 0 SATA IRQ4 COM1 IRQ12 PS 2 mouse IRQ5 SMBus Controller IRQ13 FPU IRQ6 FDC IRQ14 Primary IDE IRQ7 Available IRQ15...

Page 78: ...CPEX Series CyberResearch CPU Cards 66 Copyright 2005 CyberResearch Inc...

Page 79: ...lectric surge to the board 2 Connect the ATX power button switch to the PW_SW power button And connect the power cable from Backplane to ATXCTL connector of CPU card 3 To turn on the system press the...

Page 80: ...tion and provides BIOS and DOS disk services Please use Ctrl I keys to enter the Intel R RAID for Serial ATA status screen which should appear early in system boot up during the POST Power On Self Tes...

Page 81: ...m After the above message shows press Ctrl and I keys simultaneously to enter the RAID Configuration Utility 2 Creating Deleting and Resetting RAID Volumes After pressing the Ctrl and I keys simultane...

Page 82: ...AID 1 array by using the upper arrow or down arrow keys to scroll through the available values and pressing the Enter key to select and advance to the next field The available values range from 4KB to...

Page 83: ...value Select the RAID level Striping for RAID0 and Mirror for RAID1 by scrolling through the available values by using the upper arrow or down arrow and press the Enter key to select and advance to th...

Page 84: ...ume again Then you will return to the main menu with an updated status as follows 7 Scroll to option 4 Exit and press Enter to exit the RAID Configuration utility The following prompt appears 8 Click...

Page 85: ...d CT USA www cyberresearch com Select option 2 Delete RAID Volume from the main menu window and press Enter key to select a RAID volume for deletion The following window will appear Select the volume...

Page 86: ...ht 2005 CyberResearch Inc 3 Reset Disks to Non RAID Select option 3 Reset Disks to Non RAID and press Enter to delete the RAID volume and remove any RAID structures from the drives The following scree...

Page 87: ...tings and possibly change settings before reinstalling the modules 3 Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board module or...

Page 88: ...CPEX Series CyberResearch CPU Cards 76 Copyright 2005 CyberResearch Inc Intentionally Blank...

Page 89: ...d the sole and exclusive liability of the Seller its successors or assigns in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory including but not l...

Page 90: ...CPEX Series CyberResearch CPU Cards 78 Copyright 2005 CyberResearch Inc Intentionally Blank...

Page 91: ......

Page 92: ...CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 483 8815 F 203 483 9024 www cyberresearch com...

Reviews: