CyberResearch COMT 366F User Manual Download Page 21

CyberResearch

® 

Serial Communications 

 

COMT 366 Series 

CyberResearch, Inc

.  

13

 

25 Business Park Drive 

 

P: (203) 483-8815; F: (203) 483-9024 

Branford, CT USA 

 

www.cyberresearch.com 

Warranty Notice 

CyberResearch, Inc. warrants that this equipment as furnished will be free from 
defects in material and workmanship for a period of one year from the confirmed 
date of purchase by the original buyer and that upon written notice of any such 
defect, CyberResearch, Inc. will, at its option, repair or replace the defective item 
under the terms of this warranty, subject to the provisions and specific exclusions 
listed herein. 
This warranty shall not apply to equipment that has been previously repaired or 
altered outside our plant in any way which may, in the judgment of the manufacturer, 
affect its reliability. Nor will it apply if the equipment has been used in a manner 
exceeding or inconsistent with its specifications or if the serial number has been 
removed. 
CyberResearch, Inc. does not assume any liability for consequential damages as a 
result from our products uses, and in any event our liability shall not exceed the 
original selling price of the equipment. 
The equipment warranty shall constitute the sole and exclusive remedy of any Buyer 
of Seller equipment and the sole and exclusive liability of the Seller, its successors 
or assigns, in connection with equipment purchased and in lieu of all other 
warranties expressed implied or statutory, including, but not limited to, any implied 
warranty of merchant ability or fitness and all other obligations or liabilities of seller, 
its successors or assigns. 
The equipment must be returned postage prepaid. Package it securely and insure it. 
You will be charged for parts and labor if the warranty period has expired.

 

Returns and RMAs 

If a CyberResearch product has been diagnosed as being non-functional, is visibly 
damaged, or must be returned for any other reason, please call for an assigned 
RMA number. The RMA number is a key piece of information that lets us track and 
process returned merchandise with the fastest possible turnaround time. 

PLEASE CALL FOR AN RMA NUMBER! 

Packages returned without an RMA number will be refused! 

In most cases, a returned package will be refused at the receiving dock if its  
contents are not known. The RMA number allows us to reference the history of 
returned products and determine if they are meeting your application’s requirements. 
When you call customer service for your RMA number, you will be asked to provide 
information about the product you are returning, your address, and a contact person 
at your organization.

 

Please make sure that the RMA number is prominently  

displayed on the outside of the box.

 

• Thank You • 

Summary of Contents for COMT 366F

Page 1: ...eproduced without permission COMT 366 Series RS 232 to RS 485 Converter with LCD 38 4 kbps Data Rate COMT 366M DB 25M Connector COMT 366F DB 25F Connector CyberResearch Inc www cyberresearch com 25 Bu...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...ks CyberResearch and COMT 366 Series are trademarks of CyberResearch Inc Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademar...

Page 6: ...COMT 366 Series CyberResearch Serial Communications iv Copyright 2001 CyberResearch Inc COMT 366 Series...

Page 7: ...uch interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference If this occurs the user will be required to take whatever m...

Page 8: ...1 1 1 The LCD 1 2 0 Specifications 3 2 1 Interface 3 2 2 Connectors 3 2 3 Data Rate 3 2 4 Switches 3 2 5 Indicators 3 2 6 Power 3 2 7 Size 3 2 8 Environment 3 3 0 Installation 4 4 0 Operation 5 4 1 T...

Page 9: ...r In the case of a system problem it provides information as to the status of the local link The logo shown on the LCD display indicates the unit is powered For power stealing devices such as a conver...

Page 10: ...be displayed simultaneously A variation in display intensity between lower and upper segments will give the user a perception of the amount of data being transmitted The LCD display also shows the sta...

Page 11: ...inal block 2 3 Data Rate 0 to 38 4 KBPS 2 4 Switches DTE DCE selector switch allows reversing of Pins 2 and 3 of EIA 232 connector Four position dip switch two switches set operating mode two switches...

Page 12: ...ter will poll the slaves through the single twisted pair and request that only one device access the line at a time The COMT 366 can operate at the following Baud rate distance combinations Baud rate...

Page 13: ...er The COMT 366 can only transmit data on the RS 485 port if RTS is asserted Note On the COMT 366 only if the RTS signal cannot be controlled then carefully open the covers and locate JP1 and move the...

Page 14: ...eases the chosen value becomes more critical to error free operation Typically devices at the end of a long bus are terminated and units multi dropped between the ends are not terminated The cable use...

Page 15: ...e communication parameters set the same On the COMT 366 look at the LCD if RD is shown as a constant high or streaming see Section 1 1 The LCD then the wires are reversed d One of the two wires is bro...

Page 16: ...ter may now be tested by setting the following switches DCE on COMT 366 DTE Dip Switch 1 ON 2 OFF 3 OFF 4 ON If the converter is functioning correctly any data entered on the keyboard of the terminal...

Page 17: ...erresearch com 6 0 RS 232 Pin Number Assignments Pin EIA CCITT Name 2 BA 103 Transmit Data 3 BB 104 Receive Data 4 CA 105 Request to Send 5 CB 106 Clear to Send 6 CC 107 Data Set Ready 7 AB 102 Signal...

Page 18: ...ansformer supplies low voltage AC and the required 12 12 and 5 Volts are generated internally For COMT 366 supply 12 volts on Pin 9 7 1 COMT 366 The COMT 366 is powered by a small wall mounted transfo...

Page 19: ...mper settings and possibly change settings before reinstalling the modules 3 Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board m...

Page 20: ...COMT 366 Series CyberResearch Serial Communications 12 Copyright 2001 CyberResearch Inc Intentionally Blank...

Page 21: ...pment and the sole and exclusive liability of the Seller its successors or assigns in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory including b...

Page 22: ...COMT 366 Series CyberResearch Serial Communications 14 Copyright 2001 CyberResearch Inc Intentionally Blank...

Page 23: ......

Page 24: ...CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 483 8815 F 203 483 9024 www cyberresearch com...

Reviews: