CyberPower UPS 1200E User Manual Download Page 2

 

 Functional Test

 

 

AC Mode 

The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also 
regulates the output voltage to within a narrow range. 
 

On-Battery Mode

 

The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local 
users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to 
the load from the battery and through its inverter and the output voltage and frequency of the UPS are 
regulated within a narrow range 
 

1. Switch 

On 

Press the power switch on the front panel then the status LCD will

 

light up.   

 

2. Switch 

Off 

Press again the power switch, the status LCD on the front panel will go off.   

 

3. 

Cold Start / Start on Battery:   

          This UPS can be turned on even when AC is not present. 

 

Press the power switch on the front panel then the status LCD will light up.   
 

ROUTINE MAINTENANCE AND STORAGE

 

 

ROUTINE MAINTENANCE

 

1. 

Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent that 
contains alcoholic ingredient.   

 
2. 

The expected lifetime of the battery is around 3 years. Improper operation and harsh environment 
will reduce the actual lifetime. 

 
3. 

Unplug the UPS from power inlet if the UPS will not operate for long period of time. 

 

STORAGE

 

1. 

First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables 
connected the UPS to avoid battery drain.   

 
2. 

The UPS should be stored in a cool dry location. 

 
3. 

Make sure the battery is fully charged before the UPS is stored. 

 

4.

 

For extended storage in moderate climates, the battery should be charged for 12 hours every 3 
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat 
it every 2 months in high temperature locations.

 

 

 

 

TROUBLE SHOOTING

 

 

Problem 

Possible Cause 

Solution 

Batteries are not fully 
charged. 

Recharge the battery by leaving the UPS 
plugged in. 

The UPS does 
not perform 
expected 
runtime. 

Battery is slightly worn out. 

Contact CyberPower Systems at 
[email protected]

The on/off switch is 
designed to prevent 
damage by rapidly turning it 
off and on.   

Turn the UPS off. Wait 10 seconds and 
then turn the UPS on.   

The unit is not connected to 
an AC outlet. 

The unit must be connected to a 
220-240V 50/60Hz outlet.     

The battery is worn out. 

Contact CyberPower Systems at 
[email protected]

The UPS will not 
turn on. 
 

Mechanical problem. 

Contact CyberPower Systems at 
[email protected]

Circuit breaker is tripped 
due to overload 

Turn the UPS off and unplug at least one 
piece connected equipment. Unplug the 
power cord of the UPS then press the 
circuit breaker knob. 

Batteries are discharged 

Allow the unit to recharge for at least 4 
hours. 

Outlets do not 
provide power to 
equipment 

Unit has been damaged by 
a surge or spike. 

Contact CyberPower Systems at 
[email protected]

The serial/USB cable is not 
connected. 

Connect the serial/USB cable to the UPS 
unit and an open serial port on the back 
of the computer. You must use the cable 
that came with the unit. 

The serial/USB cable is 
connected to the wrong 
port. 

Try another serial/USB port of your 
computer. 

The unit is not providing 
battery power. 

Shutdown your computer and turn the 
UPS off. Wait 10 seconds and turn the 
UPS back on. This should reset the unit. 

PowerPanel® 
Personal Edition 
is inactive (all 
icons are gray). 

The serial cable is not the 
cable that was provided with 
the unit. 

You must use the cable included with the 
unit for the software. 

 

CyberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects in 

design, assembly, materials and workmanship for two years ( battery is only one year) from the date of 

original purchase.  Any warranty services, please contact your local dealers or distributors.

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS 

 

Model 

 

Value 1200E 

Value 1500E

 

Value 2200E 

Capacity  (VA) 

1200VA 

1500VA 

2200VA 

Capacity  (Watts) 

720W 

900W 

1320W 

Input  

 

 

 

Input Voltage Range 

160VAC~270VAC 

Frequency Range 

50/60Hz +/-3Hz(Auto Sensing) 

Output  

 

 

 

On Battery Output 
Voltage 

Simulated Sine Wave at /-7% 

On Battery Output 
Frequency  

50/60 Hz 

Overload Protection 

On Utility: Circuit Breaker, On Battery: Internal Current Limiting 

Physical 

 

 

 

 

Total # of UPS 
Receptacles 

(6) IEC 320 C13 

Maximum Dimensions 

32.6cm(L)

×

14.cm(W)

×

18cm(H) 

Weight   

13.0 kg / 28.6 Lbs 

14.3 kg / 31.5 Lbs 

15.4 kg / 33.9 Lbs 

Battery 

 

 

 

 

Sealed Maintenance 
Free Lead Acid Battery

12V / 7Ah x2 

12V / 8.5Ah x2 

12V / 9Ah x2 

Typical Recharge Time

8 Hours 

Warning Diagnostics 

Indicators 

Power On, UPS Status Display, Capacity Display, Digital Value 

Display 

Audible Alarms 

On Battery, Low Battery, Overload 

Environmental 

 

 

 

 

Operating Temperature

+32

°

F to 104

°

F ( 0

°

C to 40

°

C ) 

Operating Relative 
Humidity 

0 to 95% NON-CONDENSING 

Communication 

 

 

 

 

PowerPanel

®

 Personal 

Edition Software 

Windows 98/ME/2000/NT/XP/Vista 

Management 

 

 

 

 

Auto-Charger Yes 
Auto-Restart Yes 
USB Yes 

 
 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

 

LCD Indication 

 

 

Line mode

 

UPS Status Display 

Capacity Display 

Digital Value Display 

Select SW 

Press 

Load 
Cap. 

Battery 

Cap. 

Input 

Voltage 

Output 

Voltage 

Run 

Time 

of Load 

of Batt. 

Initial 

V X -- X  V 

 

 

 

 

1st 

V X -- X  V 

 

 

 

 

2nd 

V X -- X  V 

 

 

 

 

3rd 

V X -- X  X 

 

 

 

 

4th 

V X -- X  V 

 

 

 

 

5th(Return) 

V X -- X  V 

 

 

 

 

Press >3sec 

(Sound Disable) 

-- -- -- -- -- -- -- 

Press >3sec 

again 

(Sound Enable) 

-- -- -- -- -- -- -- 

(Overload) V 

-- 

-- -- -- -- -- -- -- 

“V” : Illuminated,    “X” : Not Illuminated,    “--“ : Either 

 

Battery mode 

UPS Status Display 

Capacity Display 

Digital Value Display 

Select SW 

Press 

Load 
Cap. 

Battery 

Cap. 

Input 

Voltage 

Output 

Voltage 

Run 

Time 

of Load 

of Batt. 

Initial 

X V -- X  X 

 

 

 

 

1st 

X V -- X  X 

 

 

 

 

2nd 

-- 

V X      V  

3rd 

X V -- X  X 

 

 

 

 

4th 

X V -- X  X 

 

 

 

 

5th(Return) 

X V -- X  X 

 

 

 

 

Press >3sec 

(Sound Disable) 

-- -- -- -- -- -- -- 

Press >3sec 

again 

(Sound Enable) 

-- -- -- -- -- -- -- 

(Overload) X 

-- 

-- -- -- -- -- -- -- 

“V” : Illuminated,    “X” : Not Illuminated,    “--“ : Either

 

 

For more information, visit eu.cyberpowersystems.com or contact 

CyberPower Systems B.V.

 

Flight Forum 3545 5657DW Eindhoven The Netherlands 

Tel: +31 40 2348170, E-MAIL: [email protected]   

CyberPower Systems Inc. (USA

) 4241 12th Avenue East, Suite 400, Shakopee, MN 55379, U.S.A. 

Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL: [email protected]   

Entire contents copyright ©2004 CyberPower Systems B.V., All rights reserved. Reproduction in whole 

or in part without permission is prohibited. PowerPanel

®

 and PowerPanel

®

 Plus are trademarks of 

CyberPower Systems (USA) Inc. 

 

 