CyberPower CPS900AVR User Manual Download Page 10

 

 

 

TROUBLESHOOTING 

 
 

Problem 

 

Possible Cause 

 

Solution 

 

Full-time surge protection 
outlets stop providing power to 
equipment. 

 

 

Circuit breaker has tripped due 
to an overload. 
 
 
 

Turn the UPS off and unplug at least one piece of equipment.  
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on. 

 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

The UPS does not perform 
expected runtime. 

 

 

 

 Battery is slightly worn out. 

Contact CyberPower Systems about replacement batteries at 

[email protected]

 

 

The on/off switch is designed to 
prevent damage by rapidly 
turning it off and on. 

Turn the UPS off.  Wait 10 seconds and then turn the UPS on. 

 

 

The unit is not connected to an 
AC outlet. 

The unit must be connected to a 110/120v 60Hz outlet.   
 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries at 

[email protected]

 

 

The UPS will not turn on. 

 

 

 

 

 
 

Mechanical problem. 

Contact CyberPower Systems about at 

[email protected]

 

The serial cable is not 
connected. 

Connect the serial cable to the UPS unit and an open serial port 
on the back of the computer.  You must use the cable that came 
with the unit. 

The serial cable is connected to 
the wrong port. 

Check the back of the computer for an additional serial port.  
Move the cable to this port. 

The unit is not providing battery 
power. 

Shutdown your computer and turn the UPS off.  Wait 10 seconds 
and turn the UPS back on.  This should reset the unit. 

PowerPanel™ Plus is inactive 
(all icons are gray). 

The serial cable is not the cable 
that was provided with the unit. 

You must use the cable that was included with the unit for the 
software and the unit to be able to communicate. 

 

 

SPECIFICATIONS 

Model CPS900AVR 

General 

Capacity 900VA 

(500W) 

Frequency 57Hz 

to 

63Hz 

Input 

Voltage Range 

85v – 150v 

AVR Max. boost 26% of input voltage for output 

regulation while input voltage is from 8% to 30% under 

nominal. 

Line Conditioning 

Regulation 

AVR buck 13% of input voltage for output regulation 

while input voltage is from 8% to 26% over nominal 

On Battery Output 

voltage regulation 

120 Vac ±5% (user adjustable) 

Transfer Time 

4ms typical, including detection time 

On battery output 

wave form 

Simulated Sine wave Form 

UPS-Output 

Max. load 

900VA(500W) 

Full-time Surge Protection Output 

Max. Load 

12 Amps 

Battery type 

Sealed, Maintenance-free lead acid battery 

Number of Batteries 

12V/7AH x 2 

Battery 

Recharge Time 

4 to 8 hours from total discharge 

Communication 

RS-232 with Plug and Play interface. 

LED Indicators 

Power On, Electrical Wiring Fault, AVR, Using Battery, 

Check Battery 

3 Battery-powered and full-time surge protection 

Interface 

Output Receptacles 

6 full-time surge protection 

 
 

 

 
 

Summary of Contents for CPS900AVR

Page 1: ...User Manual for CPS900AVR and PowerPanel Plus Software User Manual ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com faqs htm...

Page 2: ...source before servicing the battery or installing a computer component DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applicatio...

Page 3: ...lets Provides three surge protected outlets to protect connected equipment against surges and spikes 3 All outlets Designed for AC Adapters Allows six AC power adapter blocks to be plugged into the UP...

Page 4: ...a telephone cable from the wall jack outlet to the in jack of the UPS Connect a telephone cable the out jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telep...

Page 5: ...back of your computer Note You must use the cable that was supplied with the unit 10 Plug the UPS into an AC outlet turn the UPS on and then start your computer 11 Click on Start point to Settings and...

Page 6: ...used 6 Version This shows the hardware version 7 Status Bar The area display messages about the status of the software 8 Schedule Button Click this button to access the Schedule Window POWERPANEL PLU...

Page 7: ...the UPS without having to unplug the unit from the wall When Run is clicked the will switch to battery power and the unit will beep 8 About This button will display information about the software as w...

Page 8: ...ow 7 Closed Application Information Option Button When this option is selected the log will display the names and location of any files that were auto saved by the software TESTING YOUR UPS SYSTEM Onc...

Page 9: ...erload Occurs in the Battery power Supplied Outlets Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Off Off Off On...

Page 10: ...back of the computer for an additional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back...

Page 11: ...if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if...

Page 12: ...f you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of this Limited Warranty LIMITED WARRANTY CyberPower warrants to you...

Page 13: ...cted Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the power util...

Page 14: ...ients in such transmission 3 Damage from any circumstance described as excluded above with respect to the Product 4 Damages from fire flood wind rain rising water or leakage or breakage of plumbing fr...

Page 15: ...nect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed...

Reviews: