CPS625AVR
Guaranteed Uninterruptible Power System
If you are NOT using PowerPanel™:
1. Have your computer and UPS turned on.
2. Unplug the UPS from the wall to simulate
a power failure.
3. The UPS will begin beeping, indicating a
power failure.
4. Save and close any open files.
5. Shut down the operating system.
6. Once the computer system is shutdown,
turn the UPS off.
As the battery discharges, the unit will beep more rapidly, indicating that the battery is nearing dis-
charge. Once the test is complete, plug the UPS back in and start your computer. Please allow 4
hours for the UPS to recharge before attempting another self-test.
DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power
ON
Wiring
Fault
Circuit
Breaker
Alarm
CONDITION
On Off Set Off
Normal or AVR is maintaining a consis-
tent power
Off On/Off Set
Two
Beeps
Utility Failure-
the UPS is providing power
to battery power-supplied outlets from its
battery.
Off On/Off Set
Rapid
Beeps
Utility Failure-
The UPS is providing battery
power. Rapid beeps indicate the unit will run
out of power shortly.
Off Off Up
Two
Beeps
or
Rapid
Beeps
System Overload-
Occurs when connected
equipment exceeds the rating of unit. Turn
the UPS off, unplug at least one piece of
equipment, wait 10 seconds, reset the circuit
breaker and turn the unit on.
Off On/Off Set
Long
Beep
Battery Overload-
Occurs when connected
equipment exceeds the rating of battery
outlets of the unit. Turn the UPS off, unplug
at least one piece of equipment from battery
outlets, wait 10 seconds, reset the circuit
breaker and turn the unit on.
On/Off On
Set None
Electrical Wiring Fault- Indicates a wiring
problem with the AC outlet
such as bad
ground, miss ground, or reversed wiring.
User is advised to disconnect all electrical
equipment from the outlet and have an
electrician check the outlet to insure proper
wiring.
7