User’s Manual 

K01-0000064-00

 

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. 

Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!  

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!  

To reduce the risk of electric shock, do not remove the cover except to service the battery.    There are no user serviceable parts 

inside except for battery. 

CAUTION!  

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!  The 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!  

To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer 

component. 

CAUTION!

    To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in 

accordance with the National Electric Code, ANSI/NFPA 70. 

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!  

CyberPower Systems does not sell products for life support or medical 

applications.  

DO NOT

 use in any circumstance that would affect, operation,  safety of any life support equipment or with any medical 

applications or patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation 

from the aquarium can cause the unit to short out. 

 
 

INSTALLING YOUR UPS SYSTEM   

 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(1) UPS unit; (1) User’s manual; (1) PowerPanel

®

 Personal Edition software CD; (1) USB device cable; (1) Telephone cable; (1) Warranty 

registration card; (1) Coaxial Cable 

 

WHAT IS AVR?

 

The

 

CP685AVR-G / CP825AVR-G provide complete power protection from 

utility power that is not always consistent.    The CP685AVR-G / CP825AVR-G 

feature 890 Joules / 1030 Joules of surge protection, and provide long lasting 

battery backup during power outages.  The CP685AVR-G / CP825AVR-G 

ensure consistent power to your computer system and include software that 

will automatically save your open files and shutdown your computer system 

during a utility power loss. 

 

AUTOMATIC VOLTAGE REGULATOR

 

The

 

CP685AVR-G / CP825AVR-G

 

stabilize utility power voltage levels that 

can be inconsistent.    The incoming utility power may be damaging to 

important data files and hardware, but with Automatic Voltage Regulation,

 

the 

computer will not experience damaging voltage levels.    An Automatic Voltage 

Regulator automatically increases low or decreases high voltage to a 

consistent, computer safe 110v/120v.    The unit’s powerful battery will provide 

power only if the incoming voltage drops below 90v or increases above 140v. 

 

SYSTEM FUNCTIONAL BLOCK DIAGRAM 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1.

  Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (685VA/390W for CP685AVR-G, 

825VA/450W for CP825AVR-G).    If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit 

to shut down or the circuit breaker to trip.     

2.

  There are many factors that can affect the amount of power that your computer system will require.    It is suggested that the load you will be 

placing on the outlet not exceed 80% of the unit’s capacity. 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt.    However, 

recharging the 

battery for at least 8 hours

 is recommended to ensure that the battery’s maximum 

charge capacity is achieved.    A loss of charge may occur during shipping and 

storage.    To recharge the battery, simply leave the unit plugged into an AC outlet. 

2.  With the UPS unit off and unplugged, connect your computer, monitor, and any other 

peripherals requiring battery backup into the battery power supplied outlets.    Plug 

your other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets.   

DO NOT plug a laser printer, paper 

shredder, copier, space heater, vacuum, sump pump or other large electrical device into battery and surge protected outlets.    The 

power demands of these devices will overload and possibly damage the unit. 

3.  To protect a network connection from surges, connect a network cable into the IN jack of the UPS. Then connect 

a network cable from the OUT jack on the UPS to the network device. 

4.  Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).    Make sure the wall branch outlet is 

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air 

conditioner, refrigerator, copier, etc…).    The warranty prohibits the use of extension cords, outlet strips, and surge strips. 

5.  Press the power switch to turn the unit on.    The power on indicator light will illuminate and the unit will “beep”. 

6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.    Make sure the circuit breaker is depressed and then turn the UPS on. 

7.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

8.  To store your UPS for an extended period, cover it and store with the battery fully charged.    While in storage recharge the battery every three 

months to ensure battery life. 

 

 

 

BASIC OPERATION 

 

DESCRIPTION 

 

 

Battery and Surge Protected Outlets 

The unit has four battery powered/surge suppression outlets for connected 
equipment to ensure temporary uninterrupted operation of your equipment 
during a power failure. (

 DO NOT plug a laser printer, paper shredder, 

copier, space heater, vacuum, sump pump or other large electrical 
device into battery and surge protected outlets.    The power demands 
of these devices will overload and possibly damage the unit.)

 

 

Full-Time Surge Protection Outlets 

The unit has four surge suppression outlets which are always on. 

 

Power Switch 

Press the power button to turn the UPS ON or OFF. 

 

Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. 

 

Electrical Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If 
this is illuminated, it is recommended to disconnect all electrical equipment from the outlet and have an electrician verify the outlet is 
properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, telephone line, network or Ethernet connection (RJ11/RJ45).

 

 

Circuit Breaker 

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.   

 

USB Port and DB-9 Contact Closure Port to PC 

The ports allow connection and communication between the USB or DB-9 port on the computer and the UPS unit.    The UPS 
communicates its status to the PowerPanel

®

 Personal Edition software.    The DB9 interface is compatible with Power Management 

provided by Windows

®

 NT/2000/2003/XP and the USB interface is compatible with the Power Management provided by Windows Vista, OS 

X, and Linux.. 

Note: Only one of the ports, USB or DB-9, can be used to communicate with your computer at one time. 
Note: To install PowerPanel

®

 Personal Edition Software the computer will need Microsoft

R

  Internet Explore 6.0 or higher installed. 

Note: If using the DB-9 port, users need to order the standard RS-232 cable. If you have any questions, email CyberPower 
technical support for help. 

[email protected]

 

 

Outlets Designed for AC Adapters 

The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets. 

 

Coax/Cable/DSS Surge Protection 

The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.

 

 

REPLACING THE BATTERY 

 
Replacement of batteries located in an 

OPERATOR ACCESS AREA

1. 

When replacing batteries, replace with the same number of the following battery: BP8-12 / BB for CP685AVR-G; HR1234W / BB for 
CP825AVR-G. 

2. 

CAUTION! 

  Risk of Energy Hazard, 12 V, maximum 8(BP8-12 for CP685AVR-G) or 9(HR1234W for CP825AVR-G) Ampere-hour battery. 

Before replacing batteries, remove conductive jewelry such as chains, wrist watches, and rings.   

3. 

CAUTION! 

  Do not dispose of batteries in a fire. The batteries may explode; 

4. 

CAUTION! 

  Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. 

CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING 
TO LOCAL REGULATIONS. 

 

TO REPLACE THE BATTERY 

1.  Turn off and unplug all connected equipment. 
2.  Unplug it from the AC power source. 
3.  Turn the UPS upside down. 
4.  Remove the 1 retaining screw. 
5.  Slide the battery compartment cover completely off of the unit. 
6.  Remove the battery from the compartment. 
7.  Disconnect the battery wires from the battery. 
8.  Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery. 
9.  Put the battery back into the compartment. 
10.  Slide back the battery compartment cover and tighten the retaining screw. 
11.  Charge the unit for 4 – 8 hours to fully charge the battery. 

REMINDER:  

Batteries are considered 

HAZARDOUS WASTE

 and must be disposed of properly.    Most retailers that sells lead-acid batteries 

collects used batteries for recycling, as required by local regulations. 

 

 

TROUBLE SHOOTING 

 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit.

 

Circuit breaker has tripped due to an 
overload. 

Turn the UPS off and unplug at least one piece of equipment.   
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on.

 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

The UPS does not perform 
expected runtime. 

Battery is worn out. 

Contact CyberPower Systems about replacement batteries at 
[email protected] 

The on/off switch is designed to 
prevent damage by rapidly turning it 
off and on. 

Turn the UPS off.    Wait 10 seconds and then turn the UPS on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 110/120v 60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries at 
[email protected] 

The UPS will not turn on. 
 

Mechanical problem. 

Contact CyberPower Systems at 
[email protected] 

The USB / serial cable is not 
connected. 

Connect the USB / serial cable to the UPS unit and an open 
USB / serial port on the back of the computer.    You must use 
the cable that came with the unit. 

The USB / serial cable is connected 
to the wrong port. 

Check the back of the computer for an additional USB / serial 
port.    Move the cable to this port. 

The unit is not providing battery 
power. 

Shutdown your computer and turn the UPS off.    Wait 10 
seconds and turn the UPS back on.    This should reset the unit. 

PowerPanel

®

 Personal Edition is 

inactive (all icons are gray). 

The serial cable is not the cable that 
was included with the UPS unit. 

If you are using a serial cable you must use a CyberPower serial 
cable.    If you need this cable please contact technical support.   

[email protected]

 

Additional troubleshooting information can be found at 

www.cyberpowersystems.com/support.htm 

EMI Filter 

Surge 

Suppressor

 

AVR 

Charger 

AC/DC 

Battery

Inverter

Input 

Output 

Normal Mode 
Battery Mode 