Problem

 

Possible Cause 

Solution

 

Circuit breaker button is 
projecting from the back of the 
unit.

 

Circuit breaker has tripped due to an 
overload. 

Turn the UPS off and unplug at least one piece of 
equipment.    Wait 10 seconds, reset the circuit breaker by 
depressing the button, and then turn the UPS on.

 

The UPS does not perform 
expected runtime. 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is worn out. 

Contact CyberPower Systems about replacement batteries. 

The UPS will not turn on. 

The on/off switch is designed to 
prevent damage from rapidly turning 
it off and on. 

Turn the UPS off. Wait 10 seconds and then turn the UPS 
on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 120V 60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries.   

Mechanical problem. 

Contact CyberPower Systems. 

Additional troubleshooting information can be found under 

“Support” at 

CyberPowerSystems.com

 

 

 

 

Serial 

A1500SP1 

Model 

CP1500AVRLCDa 

Capacity 

1500VA / 900W 

Nominal Input Voltage 

120V 

Input Frequency 

60 Hz ± 3 Hz 

On-Battery Output Voltage 

120Vac ± 5% 

Max. Load for UPS Outlets 

(5 Outlets) 

1500VA / 900W 

Max. Load for Full-Time 

Surge Protection outlets 

12 Amp 

(12 outlets) 

On-Battery Output Wave 

Form 

Simulated Sine Wave 

Operating Temperature 

+ 32°F to 104° F / 0° C to 40° C 

Operating Relative Humidity 

0 to 90% non-condensing 

Size (W x H x D) 

3.9" x 11" x 14"   

(100 x 280 x 355 mm) 

Net Weight 

25lbs / 11.3kg 

Battery Type 

CyberPower / RB1290X2 

Typical Battery Recharge 

Time 

8 hours   

Typical Battery Life 

3 to 6 years, depending on number of discharge/recharge cycles 

Recommended Battery 

Sealed Maintenance Free Lead Acid Battery 

Safety Approvals 

UL1778(UPS),

 

CAN/CSA C22.2 No 107.3., FCC/DoC Class B 

 
SYSTEM FUNCTIONAL BLOCK DIAGRAM

 

 
 
 
 
 
 
 
 

 
FCC Compliance Statement

   

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and 

can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures: 

- Reorient or relocate the receiving antenna. 

- Increase the separation between the equipment and receiver. 

- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. 

- Consult the dealer or an experienced radio/TV technician for help" 

Warning:

 Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the 

equipment. 

Canadian Compliance Statement 

CAN ICES-3 (B)/NMB-3(B) 

 

 

 

Advanced Energy-Saving Patented Bypass Technology

 

CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to   

75% compared to conventional UPS models. Even when utility power is normal, conventional UPS models   

constantly pass power through a transformer. By contrast, under normal conditions the advanced circuitry   

of a GreenPower UPS™ bypasses the transformer. As a result, the power efficiency is significantly   

increased while decreasing waste heat, using less energy, and reducing energy costs. 

When an abnormal power condition occurs, the GreenPower UPS™ automatically runs power through its   

transformer to regulate voltage and provide 

“safe” power. Since utility power is normal over 88% of the time, the GreenPower UPS™ operates 

primarily in its efficient bypass mode. 

The GreenPower UPS™ is also manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the 

most environmentally-friendly on the market today. 

 

 

 

 

Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee. 

 
Where Can I Get More Information?

 

The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. 
CyberPower is the warrantor under this Limited Warranty. 

For further information please feel free to contact CyberPower at Cyber Power Systems (USA), Inc. 4241 12

th

 Ave E., STE 400, Shakopee, MN 55379; 

call us at (877) 297-6937; or submit a web ticket online at cyberpowersystems.com/support. 
 

Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal and recycling of its UPS products. 

Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state. 

 

 

All rights reserved. Reproduction without permission is prohibited.

 

TECHNICAL SPECIFICATIONS 

Limited Warranty and Connected Equipment Guarantee 

CYBERPOWER GREENPOWER UPS

 TECHNOLOGY 

 

 

 

EMI 

Filter 

Surge 

Suppressor

 

AVR 

Charger 

AC/DC 

Battery 

Inverter 

DC/A

Input 

Output 

Normal Mode 

Battery Mode 

 

TROUBLESHOOTING 

FCC Compliance Statement

 

Reviews: