background image

08

GETTING TO KNOW YOUR IPC-R1ix

2.2.2  Rest Tact Switch

It is a hardware reset switch. Use this switch to reset the system without turning 
off the power. Momentarily pressing the switch will activate a reset.

2.2.3  Power, HDD LED Indicator

Isolated

DIO 2

Reset

COM 1

COM 2

| LAN 2

VGA

DVI-D

V+

1

2

| LAN 1

V-

COM 4

COM 3

Isolated

DIO 1

On | Off

Isolated

DIO 2

Reset

COM 1

COM 2

| LAN 2

VGA

DVI-D

V+

1

2

| LAN 1

V-

COM 4

COM 3

Isolated

DIO 1

On | Off

Summary of Contents for IPC-R1ix

Page 1: ...USER Manual USER Manual IPC R1ix Fanless Robust Computing System With 4 PCI PCIe Slots 3rd Gen Intel Core i7 i5 i3 Mobile Processor ...

Page 2: ...e with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC The product s described in this manual complies with all applicable European Union CE directives if it has a CE marking For computer s...

Page 3: ...Part Number Description Expansion Slots IPC R1ix Fan less Robust Computing System 2 Slots 1 PCIe x4 1 PCIe x16 Order Information ...

Page 4: ...r M340S W28M1 DDR3 4GB 1333 1066MHz RAM Micron Chip Wide Temperature 40 C 85 C 4GB RAM 8GB RAM PWA 160W WT 160W 24V 85VAC to 264VAC Power Adaptor with 3 pin Terminal Block Wide Temperature 30 C to 70 C PWA 120W 120W 24V 90VAC to 264VAC Power Adapter with 3 pin Terminal Block SCSI 20P 100 20 pin SCSI Cable 1M TMB SCSI 20P Terminal Board with One 20 pin SCSI Connector and DIN Rail Mounting Optional ...

Page 5: ...2 2 4 Dual Isolated 8 DI 8 DO 09 2 2 5 Serial Port COM 1 COM 3 COM 4 12 2 2 6 USB 2 0 Port 13 2 2 7 Serial Port COM 2 14 2 2 8 USB 3 0 Port 15 2 2 9 10 100 1000 Mbps Ethernet Port 15 2 2 10 DisplayPort 17 2 2 11 DVI D Connector HDMI Connector 17 2 2 12 VGA Connector 18 2 2 13 Audio Connector 19 2 2 14 DC in Power Terminal Block 19 20 2 3 Main Board Expansion Connectors 21 2 3 1 J2 Miscellaneous Pi...

Page 6: ...ot 45 2 3 16 Dual SO DIMM 47 2 3 17 CN25 Multiple I O 48 2 4 Main Board Jumper Setting 49 2 4 1 JP1 AT ATX Power Mode Jumper Setting 51 2 4 2 JP2 LVDS Backlight Power Selection 52 53 2 4 4 JP4 A CMOS Clear Jumper Setting 54 2 4 5 JP4 B CMOS Clear Jumper Setting 55 CHAPTER 3 HARDWARE INSTALLATION 56 CHAPTER 4 BIOS AND DRIVER SETTING 65 4 1 BIOS Settings 65 4 2 Main Menu 66 4 3 Advanced Function 67 ...

Page 7: ...data access with RAID 0 5 and 10 and hard drive failure protection with RAID 1 5 and 10 IPC R1ix series is equipped with two extend SATA III 6 Gbp s SSD HDD trays for better responsiveness and storage capability Rapid storage technology combines with RAID and two SATA III practical interfaces enhancing performance and data computing of multi core platforms IPC R1ix series is equipped with rich I O...

Page 8: ...PIO 16 GPIO Expansion PCI Express 1 PCIe x4 1 PCIe x16 Mini PCIe 1 Mini PCIe Socket PCIe USB SIM Card Socket 1 Mini PCIe Socket PCIe USB compatible with mSATA Graphics Chipset Intel GMA HD 4000 Display Memory Shared Memory up to 1 7GB Interface DB 15 VGA 1920 x 1200 Max DVI D 1920 x 1200 Max DisplayPort 1 2560 x 1600 Max DisplayPort 2 1920 x 1200 Max LVDS Dual Channel 24 bit 1920 x 1200 Max Storag...

Page 9: ...imer Reset 1 to 255 sec min Per Step HW Monitor Temperature voltages auto throttling control when CPU overheats Mechanical Chasis Construction Aluminum Housing Size W x D x H 137mm x 252mm x 210mm 5 4 x 9 9 x 8 3 Weight 3 kg 6 6 lb Mounting Wall mount by Mounting Bracket Environmental Operating Temperature 25 C to 70 C 13 F to 157 F Storage Temperature 40 C to 85 C 40 F to 185 F Humidity 10 to 95 ...

Page 10: ...other processor according to your consideration of application and performance Series Max TDP iAMT Embedded i7 3840QM 45W 3820QM 45W 3740QM 45W 3720QM 45W 3632QM 35W 3630QM 45W 3612QM 35W 3610QE 45W O 3540M 35W 3520M 35W i5 3610ME 35W O 3380M 35W 3360M 35W 3340M 35W 3320M 35W 3230M 35W 3210M 35W i3 3130M 35W 3120ME 35W O 3120M 35W 3110M 35W The processors with O are listed in Intel Embedded Roadma...

Page 11: ...05 GENERAL INTRODUCTION 1 4 Mechanical Dimension Figure 1 1 IPC R1ix 252 9 9 137 5 4 210 8 3 SCREW KHS 6 32 137 5 4 SCREW KHS 6 32 SCREW KHS 6 32 ...

Page 12: ...box which contains Cybernet Drivers Utilities DVD Wall mounting bracket M4 screws for wall mounting bracket 3 pin pluggable terminal block 1 2 4 2 2 2 Front Panel I O Functions All Input Output connectors are located on front panel of IPC R1ix series Most connectors like audio USB DVI D VGA are all designed on front panel Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 I...

Page 13: ...the power button and the blue LED is lighted up To turn off the IPC R1ix you can either issue a shutdown command in OS or just simply press the power button In case of system halts you can press and hold the power button for 4 seconds to compulsorily shut down the system Please note that a 4 seconds interval is kept by the system between two on off operations i e once turning off the system you sh...

Page 14: ... system without turning off the power Momentarily pressing the switch will activate a reset 2 2 3 Power HDD LED Indicator Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off ...

Page 15: ...sk CFast LED If the LED is on it indicates that the system s storage is functional If it is off it indicates that the system s storage is Green Power LED If the LED is solid green it indicates that the system is powered on Pin No Mapping to SIO GPIO Function 1 INPUT0 SIO_GPI50 2 INPUT 1 SIO_GPI51 3 INPUT 2 SIO_GPI52 4 INPUT 3 SIO_GPI53 5 INPUT 4 SIO_GPI54 6 INPUT 5 SIO_GPI55 7 INPUT 6 SIO_GPI56 8 ...

Page 16: ...xternal 24VDC Input DIO 2 Pin Assignment Pin No Mapping to SIO GPIO Function 1 INPUT0 SIO_GPI60 2 INPUT 1 SIO_GPI61 3 INPUT 2 SIO_GPI62 4 INPUT 3 SIO_GPI63 5 INPUT 4 SIO_GPI64 6 INPUT 5 SIO_GPI65 7 INPUT 6 SIO_GPI66 8 INPUT 7 SIO_GPI67 9 DI_COM 10 GND 11 OUTPUT0 SIO_GPO10 12 OUTPUT 1 SIO_GPO11 13 OUTPUT 2 SIO_GPO12 14 OUTPUT 3 SIO_GPO13 15 OUTPUT 4 SIO_GPO14 16 OUTPUT 5 SIO_GPO15 17 OUTPUT 6 SIO_G...

Page 17: ...ode Isolated GPI input circuit in SINK mode NPN is illustrated as follows GPI SOURCE Mode Digital GPI input signal circuit in SOURCE mode PNP is illustrated as follow GPO SINK Mode Digital GPO output circuit in SINK mode NPN is illustrated below ...

Page 18: ...e RS 232 only and provide up to 115200 bps baud rates The pin assignments are shown in the following table Serial Port Pin No RS 232 COM1 3 4 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off ...

Page 19: ...or disconnect a device whenever you want without turning off the system amounts of data You can also use these USB hosts to connect to a keyboard or a mouse The following diagram shows the pinouts for USB1 and USB2 port Pin No 1 2 3 4 USB1 5V USB1 USB1 GND USB2 5V USB2 USB2 GND 1 2 3 4 Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off ...

Page 20: ...22 5 wire RS 422 9 wire RS 485 Serial Port Pin No RS 232 RS 422 5 Wire RS 422 9 Wire RS 485 3 Wire 2 1 DCD TXD TXD DATA 2 RXD TXD TXD DATA 3 TXD RXD RXD 4 DTR RXD RXD 5 GND GND GND GND 6 DSR RTS 7 RTS RTS 8 CTS CTS 9 RI CTS The pin assignments are shown in the following table Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off ...

Page 21: ...SB 3 0 hosts on the front panel These USB 3 0 ports allow data transfers up to 5 Gb s The controller supports SuperSpeed SS Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off ...

Page 22: ... No 10 100 Mbps 1000 Mbps 1 E_TX MDI0_P 2 E_TX MDI0_N 3 E_RX MDI1_P 4 MDI2_P 5 MDI2_N 6 E_RX MDI1_N 7 MDI3_P 8 MDI3_N The Ethernet ports use standard RJ 45 jack connectors with LED indicators on the front side to show Active Link status and Speed status The LED indicators on the right bottom corners glow a solid green color when the cable is properly connected to a 100 Mbps Ethernet network The LE...

Page 23: ... D Connector HDMI Connector The DVI D connector on the front panel supports both DVI and HDMI operation mode This connector can either output DVI signals or HDMI signal Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off ...

Page 24: ... front panel to connect a VGA monitor To ensure that the monitor image remains clear be sure to tighten the monitor cable after connecting it to the IPC R1ix The VGA output mode supports up to 1920x1200 resolutions The pin assignments of the VGA connector are shown below 5 10 15 1 6 11 Pin No Description 1 Red Color Signal 2 Green Color Signal 3 Blue Color Signal 4 NC 5 Ground 6 VGA Detect 7 Groun...

Page 25: ...ntel Azalia standard To utilize the audio function in Windows you need to install corresponding drivers for both Intel QM77 chipset and Realtek ALC892 codec 2 2 14 DC in Power Terminal Block Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off Isolated DIO 2 Reset COM 1 COM 2 LAN 2 VGA DVI D V 1 2 LAN 1 V COM 4 COM 3 Isolated DIO 1 On Off ...

Page 26: ...e ground screw to the grounding surface prior to connecting the power block power connector Connect the earth ground wire to an appropriate grounded metal surface It is a 3 pin power on or power off switch through Phoenix Contact terminal block You could turn on or off the system power by using this contact This terminal block support dual function of soft power on power off instant off or delay 4...

Page 27: ... 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN3 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 SODIMM1 SODIMM2 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2...

Page 28: ...22 GETTING TO KNOW YOUR IPC R1ix IPC R1ix ...

Page 29: ...21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH23 CN7 J2 Group Pin No Description HDD...

Page 30: ...R10 R9 R2 R1 L4 L3 L2 L1 C1 C3 C5 C7 3 1 4 6 1 3 2 1 5 6 2 1 5 6 1 6 1 7 8 7 1 2 8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 ...

Page 31: ...a CFast card The IPC R1ix does not support the CFast hot swap and PnP Plug and Play functions It is necessary to remove power source first before inserting or removing the CFast card The following table shows the pinouts for CFast port CN2 CFast Pin No Pin No S1 GND PC6 NC S2 SATA_TX_P2 PC7 GND S3 SATA_TX_N2 PC8 NC S4 GND PC9 CFAST_LED_N S5 SATA_RX_N2 PC10 NC S6 SATA_RX_P2 PC11 NC S7 GND PC12 NC P...

Page 32: ...PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 C...

Page 33: ...3_P LB_ DATA3_P 6 LA_ DATA0_N LB_ DATA0_N 7 LA_ DATA3_N LB_ DATA3_N 8 PANEL_VDD 3 3V or 5V by jumper PANEL_VDD 3 3V or 5V by jumper 9 GND GND 10 LA_ DATA1_P LB_ DATA1_P 11 LA_ CLKP LB_ CLKP 12 LA_ DATA1_N LB_ DATA1_N 13 LA_ CLKN LB_ CLKN 14 GND GND 15 GND GND 16 PANEL_BACKLIGHT 12V PANEL_BACKLIGHT 12V 17 LA_ DATA2_P LB_ DATA2_P 18 PANEL_BACKLIGHT 12V PANEL_BACKLIGHT 12V 19 LA_ DATA2_N LB_ DATA2_N ...

Page 34: ... 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH23 CN7 J3 Pin No Pin No 1 5V 5 GND 2 12V...

Page 35: ...3 C5 C7 3 1 4 6 1 3 2 1 5 6 2 1 5 6 1 6 1 7 8 7 1 2 8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 ...

Page 36: ...10 R9 R2 R1 L4 L3 L2 L1 C1 C3 C5 C7 3 1 4 6 1 3 2 1 5 6 2 1 5 6 1 6 1 7 8 7 1 2 8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 M...

Page 37: ... 1 4 6 1 3 2 1 5 6 2 1 5 6 1 6 1 7 8 7 1 2 8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12...

Page 38: ...3 2 1 5 6 2 1 5 6 1 6 1 7 8 7 1 2 8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH1...

Page 39: ...U13 U10 U9 U5 U4 U1 R10 R9 R2 R1 L4 L3 U18U 14 U13 U10 U9 U5 U4 U1 R10 R9 R2 R1 L4 L3 L2 L1 C1 C3 C5 C7 3 1 4 6 1 3 2 1 5 6 2 1 5 6 1 6 1 7 8 7 1 2 8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71...

Page 40: ...8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ...

Page 41: ... R1ix using Pin 43 status designed for switching between mSATA drive and Mini PCIe device Status Mini PCIe card mSATA drive Pin 43 Logic 0 Logic 1 CN12 Mini PCIe Connector Pin Out Pin No Signal Name Pin No Signal Name Pin No Signal Name Pin No Signal Name 51 Reserved 52 3 3Vaux 33 PETp0 34 GND 49 Reserved 50 GND 31 PETn0 32 SMB_DATA 47 Reserved 48 1 5V 29 GND 30 SMB_CLK 45 Reserved 46 Reserved 27 ...

Page 42: ...5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 M...

Page 43: ...erved 48 1 5V 29 GND 30 SMB_CLK 45 Reserved 46 Reserved 27 GND 28 1 5V 43 Status 44 Reserved 25 PERp0 26 GND 41 3 3Vaux 42 Reserved 23 PERn0 24 3 3Vaux 39 3 3Vaux 40 GND 21 GND 22 PERST 37 GND 38 USB_D 19 Reserved 20 reserved 35 GND 36 USB_D 17 Reserved 18 GND Mechanical Key 15 GND 16 Reserved 7 CLKREQ 8 Reserved 13 REFCLK 14 Reserved 5 Reserved 6 1 5V 11 REFCLK 12 Reserved 3 Reserved 4 GND 9 GND ...

Page 44: ... 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH2...

Page 45: ... 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH2...

Page 46: ...ND 2 DO_GP0_7 15 DI_GP1_7 3 DO_GP0_6 16 DI_GP1_6 4 DO_GP0_5 17 DI_GP1_5 5 DO_GP0_4 18 DI_GP1_4 6 GND 19 GND 7 DO_GP0_3 20 DI_GP1_3 8 DO_GP0_2 21 DI_GP1_2 9 DO_GP0_1 22 DI_GP1_1 10 DO_GP0_0 23 DI_GP1_0 11 GND 24 GND 12 SMB_DAT_MAIN 25 5V 13 SMB_CLK_MAIN 26 5V ...

Page 47: ... 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 F...

Page 48: ... R2 R1 L4 L3 L2 L1 C1 C3 C5 C7 3 1 4 6 1 3 2 1 5 6 2 1 5 6 1 6 1 7 8 7 1 2 8 5 4 1 1 4 5 8 1 2 3 4 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 J...

Page 49: ...40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH23 CN7 CN23 Pin No Signal Name Pin No Signal Na...

Page 50: ...B60 GND A20 GND A61 PEG_RX10N B20 PEG_TX1N B61 GND A21 PEG_RX1P A62 GND B21 GND B62 PEG_TX11P A22 PEG_RX1N A63 GND B22 GND B63 PEG_TX11N A23 GND A64 PEG_RX11P B23 PEG_TX2P B64 GND A24 GND A65 PEG_RX11N B24 PEG_TX2N B65 GND A25 PEG_RX2P A66 GND B25 GND B66 PEG_TX12P A26 PEG_RX2N A67 GND B26 GND B67 PEG_TX12N A27 GND A68 PEG_RX12P B27 PEG_TX3P B68 GND A28 GND A69 PEG_RX12N B28 PEG_TX3N B69 GND A29 P...

Page 51: ...5 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 M...

Page 52: ...N6_N A22 PCIE_RXN6 B6 SMB_DAT_ MAIN B22 GND A7 CLK_ PCIE5_ LAN7_P A23 GND B7 GND B23 PCIE_TXP7 A8 CLK_ PCIE5_ LAN7_N A24 GND B8 3 3V B24 PCIE_TXN7 A9 3 3V A25 PCIE_RXP7 B9 N C B25 GND A10 3 3V A26 PCIE_RXN7 B10 3 3V AUX B26 GND A11 PLT_RST A27 GND B11 WAKE B27 PCIE_TXP8 A12 GND A28 GND B12 N C B28 PCIE_TXN8 A13 CLK_ PCIE5_ LAN5_P A29 PCIE_RXP8 B13 GND B29 GND A14 CLK_ PCIE5_ LAN5_N A30 PCIE_RXN8 B...

Page 53: ... 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH23 C...

Page 54: ...in No Signal Name Pin No Signal Name Pin No Signal Name Pin No Signal Name 1 PWRBT_ LED_P 2 FP_RST_ BTN_N 51 DIO1_OUT6 52 DIO2_OUT6 3 PWRBT_ LED_N 4 GND 53 DIO1_OUT7 54 DIO2_OUT7 5 FP_PWR_ BTN_P 6 PWR_LED_ P 55 GND Isolated DIO Ground 56 GND Isolated DIO Ground ...

Page 55: ...N2 22 DIO2_IN2 71 COM3_ DSR_Z 72 COM4_ DSR_Z 23 DIO1_IN3 24 DIO2_IN3 73 COM3_ RXD_Z 74 COM4_ RXD_Z 25 GND Isolated DIO Ground 26 GND Isolated DIO Ground 75 GND 76 GND 27 DIO1_IN4 28 DIO2_IN4 77 COM3_ RTS_Z 78 COM4_ RTS_Z 29 DIO1_IN5 30 DIO2_IN5 79 COM3_ TXD_Z 80 COM4_ TXD_Z 31 DIO1_IN6 32 DIO2_IN6 81 COM3_ CTS_Z 82 COM4_ CTS_Z 33 DIO1_IN7 34 DIO2_IN7 83 GND 84 GND 35 GND Isolated DIO Ground 36 GND...

Page 56: ...MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH23 CN7 JP4 JP3 JP2 JP1 jumpers A jumper is a metal bridge used to close an electric circuit It consists of two metal pins and a small metal clip often protected b...

Page 57: ...N20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH23 CN7 JP1 2 4 1 JP1 AT ATX Power Mode Jumper Setting The IPC R1ix main board contains a jumper that can switch the AT ATX Power Setting Normally this jumper should be set with Pin 4 and...

Page 58: ...19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN10 CN13 CN15 CN22 CN21 MH24 MH23 CN7 JP2 JP2 provides LVDS v...

Page 59: ... 1 7 1 7 1 7 1 7 25 22 5 4 32 1 15 5 12 10 20 19 19 20 10 2 1 5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J...

Page 60: ... 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 CN...

Page 61: ...5 15 26 25 2 1 PC17 PC1 S7 S1 15 11 10 6 51 24 16 8 17 9 1 1 19 2 20 21 39 22 40 B32 B31 A31 A32 B1 A1 B2 A2 B1 A1 A2 B2 A82 A81 B82 B81 1 2 71 72 73 74 203 204 1 2 71 72 73 74 203 204 MH1 CN2 MH9 MH21 BAT1 JP4 CN24 CN20 CN14 MH15 J4 MH22 JP3 MH16 CN16 CN17 CN18 CN19 CN12 51 1 MH10 MH8 U33 CN5 51 52 2 1 MH5 MH2 BZ1 MH7 FAN1 J1 JP1 JP2 J3 MH13 MH14 MH12 MH17 MH19 MH18 MH20 MH3 MH4 CN6 CN1 U10 CN8 C...

Page 62: ...ARE INSTALLATION Step 1 How To Open Your IPC R1ix 3 Remove the top cover of the chassis loosen the thumbscrews on the front panel by hand screwdriver Push out the top cover as the image 1 Push up the top cover as the image 2 1 2 3 4 ...

Page 63: ...ling DDR3 SO DIMM Modules Repeat Step 1 Tile the SODIMM module and insert it to the SODIMM socket As it s firmly contacted with socket connectors press it down until the clamps of the socket snap into the latching position of SODIMM module ...

Page 64: ...ARE INSTALLATION Step 3 Installing PCI PCIe Card Repeat Step 1 Loosen M3 PCI PCIe bracket screw Remove PCI PCIe bracket then install PCI PCIe module then inser the PCI PCIe card Fasten M3 PCI PCIe bracket screw ...

Page 65: ...N Step 4 Installing HDD SSD Repeat Step 1 Loosen 2 pcs F 6x6 screws from the top of the SSD HDD cover by screwcriver Lift the HDD SSD cover as the image 1 Make sure the screw hold of HDD SSD cover to match HDD SSD Image 2 1 2 ...

Page 66: ...60 HARDWARE INSTALLATION Install SATA cable to HDD SSD Image4 Replace the HDD SSD cover then fasten 2 pcs F 6x6 screws Install SATA cable to mainboard 3 4 ...

Page 67: ...CIe Module Repeat Step 1 Loosen 2 pcs F 6x6 screws Loosen 2 pcs KSH 6 32 screws as yellow circle and 3 pcs F 6x6 screws as red circle Check Mini PCIe socket as red circle Put your Mini PCIe card in the socket of mainboard then fasten 2 pcs BH M 2 5x6 ...

Page 68: ...STALLATION Step 6 Installing CPU Repeat Step 1 Loosen 2 pcs F 6x6 screws Loosen 2 pcs KSH 6 32 screws as yellow circle and 3 pcs F 6x6 screws as red circle Loosen 9 pcs PH M3x6 screws for Riser Card Remove Riser Card ...

Page 69: ...63 HARDWARE INSTALLATION Loosen 5 pcs F 6x6 screws Push chassis as the image 1 and image 2 Loosen 6 pcs M3x11 Spring screws and 8 pcs PH M3x6 screws 1 2 ...

Page 70: ...ote CPU and CPU socket triangle arrow to be the same direction Put the CPU to CPU socket and lock CPU socket Step 7 Installing Wall mounting Bracket Turn to the bottom and install Wall mounting Bracket Fix two Wall mounting brackets to the chassis with 4 pcs KH 6 32 screws ...

Page 71: ...am POST the PCI auto configuration utility LAN EEPROM information and Serial port support The BIOS setup program is accessed by pressing the Del key after the Power On Self Test POST memory test begins and before the operating system boot begins The menu bar is shown below Aptio Setup Utility Copyright C 2012 American Megatrends Inc Main Advanced Chipset Boot Security Save Exit Figure 4 1 1 BIOS M...

Page 72: ...ystem Phoenix SecureCore tm Setup Utility Main Advanced Chipset Boot Security Save Exit BIOS Information Item Specific Help BIOS Vendor American Megatrends BIOS Version Cybernet IPC R1ix 070 003b Release time 11 29 2013 13 32 22 Processor information Brand String Intel R Core TM i7 3610 DIMM 0 8192MB DDR3 DIMM 0 Not Present DIMM 0 Not Present DIMM 0 Not Present System Language English System Date ...

Page 73: ...Specific Help ACPI Settings Enable ACPI Auto Configuration Disabled Enable Hibernation Enabled This system support ACPI function as auto process You should Enable Disable that depend as your O S Enable Hibernation It is able to use Hibernate function if O S support But some O S maybe not effective with this function Figure 4 3 1 ACPI Setting setup screen ...

Page 74: ...Disabled Current Status Information SUPPORT TURNED OFF Serial Port Enable or Disable Serial port Security Device Support Enables or Disables BIOS support for security device O S will now show Security Device TCG EFT protocol and INT1A interface will not be available Current Status Information Show as below option SUPPORT TURNED OFF SUPPORT TURNED ON Figure 4 3 2 Serial Port 1 Setup screen ...

Page 75: ...t Item Specific Help CPU Configuration Intel R Core TM i7 3610QE CPU 2 30GHz Inter Virtualization Technology Disable Intel Virtualization Technology This for for Virtualization Application or platform usage when enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology ...

Page 76: ... Port 2 Empty Serial ATA Port 3 Empty Serial ATA Port 4 Empty Serial ATA Port 5 Empty SATA Controller s 0988261051 Enables or Disables integrate SATA controller for Storage device use SATA Mode Selection Determines how the SATA transfer mode for operate Here have three option for choice IDE AHCI RAID For the RAID mode operate please see appendix E for detail information Serial Port 0 5 This system...

Page 77: ...et Boot Security Save Exit Item Specific Help Intel AMT Enabled BIOS Hotkey Pressed Disabled MEBx Selection Screen Disabled Intel AMT Enables or Disables Intel R Active Management Technology BIOS extension This option just controls the BIOS extension executes Figure 4 3 5 AMT Setup screen ...

Page 78: ...on Serial Port Enabled Device Settings IO 3F8h IRQ 4 Change Settings IO 3F8h IRQ 4 Serial Port Enable or Disable Serial Port Device Setting Current IO address and interrupt resource of Serial Port Change Settings Select another device setting Here have 4 option IO 3F8h IRQ 4 IO 2F8h IRQ 3 IO 3E8h IRQ 10 IO 2E8h IRQ 11 Figure 4 3 6 Serial Port 1 Setup screen 1 ...

Page 79: ...ption IO 3F8h IRQ 4 IO 2F8h IRQ 3 IO 3E8h IRQ 10 IO 2E8h IRQ 11 Interface Mode Here have 4 option RS 232 Mode RS 422 Mode RS 485 Mode Figure 4 3 7 Serial Port 2 Setup screen 2 Phoenix SecureCore tm Setup Utility Main Advanced Chipset Boot Security Save Exit Item Specific Help Serial Port 1 Configuration Serial Port Enabled Device Settings IO 2F8h IRQ 3 Change Settings IO 2F8h IRQ 3 Interface Mode ...

Page 80: ...Enabled Device Settings IO 3E8h IRQ 10 Change Settings IO 3E8h IRQ 10 Serial Port Enable or Disable Serial Port Device Setting Current IO address and interrupt resource of Serial Port Change Settings Select another device setting Here have 4 option IO 3F8h IRQ 4 IO 2F8h IRQ 3 IO 3E8h IRQ 10 IO 2E8h IRQ 11 IO 2F0h IRQ 6 IO 2E0h IRQ 7 Figure 4 3 8 Serial Port 3 Setup screen 3 ...

Page 81: ...ther device setting Here have 4 option IO 3F8h IRQ 4 IO 2F8h IRQ 3 IO 3E8h IRQ 10 IO 2E8h IRQ 11 IO 2F0h IRQ 6 IO 2E0h IRQ 7 Figure 4 3 9 Serial Port 4 Setup screen 4 Phoenix SecureCore tm Setup Utility Main Advanced Chipset Boot Security Save Exit Item Specific Help Serial Port 4 Configuration Serial Port Enabled Device Settings IO 3F8h IRQ 4 Change Settings IO 3F8h IRQ 4 ...

Page 82: ...d network device Wake on LAN Enable or Disable integrated LAN to wake the system This function also can active by O S Phoenix SecureCore tm Setup Utility Main Advanced Chipset Boot Security Save Exit Item Specific Help PCH LAN Controller Enabled Wake on LAN Enabled Figure 4 4 1 Network Setup screen ...

Page 83: ...de Power On When plug in the power source system will auto booting Last State When plug in the power source system will keep on last power status Phoenix SecureCore tm Setup Utility Main Advanced Chipset Boot Security Save Exit Item Specific Help Restore AC Power Loss Last State Figure 4 4 2 Power Loss Setup screen ...

Page 84: ...u press Enter you can select which device you would like to boot Phoenix SecureCore tm Setup Utility Main Advanced Chipset Boot Security Save Exit Item Specific Help Boot Configuration Boot option 1 SATA PS Device Name Boot option 2 SATA PS Device Name Figure 4 5 1 Boot Setup screen ...

Page 85: ...eturn Value Description ERR_NoError Other Please reference to the Appendix error table Description Get the local DI value Syntax I16 _mnet104_read_port U16 Offset U8 Val Argument Name Type Description Offset U16 Pointer the access DI port address Val output U8 Return the value of local input interface Return Return Value Description ERR_NoError Other Please reference to the Appendix error table ...

Page 86: ...6 _mnet104_write_port U16 Offset U8 Val Argument Name Type Description Offset U16 Pointer the access DI port address Val U8 Write the value of local input interface Return Return Value Description ERR_NoError Other Please reference to the Appendix error table ...

Page 87: ... on CN12 reg index 0x62 Super I O special address port 0x2E Super I O special data port 0x2F GPIO Logical device is 0x07 B Located on Logical Device 7 write 0x07 on Reg 0x07 this setup must follow Step A that can be workable outportb Super I O special address port 0x07 outportb Super I O special data port 0x07 C Access the Super I O Register Base control for write Super I O register outportb speci...

Page 88: ...a BYTE value example unsigned char data get_data 0xF1 data Get GPI input port status on input_data variable E WDT ON OFF and Timer Counter setting Refer to GPIO setting of Step A and B located Logical 0x08 for WDT function Reg 0x30 is WatchDog ON OFF control WatchDog On set_data 0x30 0x01 WatchDog Off set_data 0x30 0x00 Reg 0xF0 is WatchDog timer counterON OFF control WatchDog counter start set_da...

Page 89: ... tolerant RAID levels RAID 0 RAID 1 RAID 5 or RAID 10 By seamlessly storing copies of data on one or more additional hard drives any hard drive can fail without data loss or system downtime When the failed drive is removed and a replacement hard drive is installed data fault tolerance is easily restored A SATA Mode for RAID Please select SATA Device to RAID mode on BIOS menu ...

Page 90: ...te C Install All Device Drivers Please follow installation sequences 1 To install chipset driver 2 To install network driver 3 To install ME driver if available 4 To install audio driver 5 To install VGA driver D Install Intel Rapid Storage Tech Software You can get the software on IPC R1ix driver CD http www intel com p en_US support highlights chpsts imsm The RAID environment has been done if yo...

Page 91: ...RAID Volume on Rapid Storage Tech Software Because we only have 2 SATA HDDs for RAID volume there are three options on this page we can choose We take RAID 1 as our example please select RAID 1 H Partition on Disk Management ...

Page 92: ...86 Appendix C You can see Volume_000 in SATA device of BIOS menu To start Disk Management tool and select Initialize Disk Then add Logical device for Windows access I HDD Caution Sign on RAID Volume ...

Page 93: ... please contact Cybernet Technical Support K Recovery Auto Re Build When Use the DIFFERENT RAID HDD There is a warning will pop up to ask you if the disk is not a member of original RAID volume If you press Rebuild it will replace the broken SATA HDD to the last one SATA HDD of RAID volume ...

Page 94: ...rpose only No part of this publication may be reproduced in any form or by any means electric photocopying recording or otherwise without prior authorization of the publisher The rights of all the brand names product names and trademarks belong to their respective owners Cybernet 2016 All rights reserved ...

Reviews: