Installing the VoIP Loudspeaker Amplifier
VoIP Loudspeaker Amplifier Operations Guide
930112A
CyberData Corporation
25
2.5 Restore the Factory Default Settings
When troubleshooting configuration problems, it is sometimes convenient to restore the device to a
known state.
Each loudspeaker amplifier is delivered with factory set default values for the parameters indicated
in
. Use the
RTFM
switch on the loudspeaker amplifier face to restore these parameters to
the factory default settings.
When you use the RTFM switch, the factory default settings are restored for
only
the parameters
indicated in
. The other parameters in the current loudspeaker amplifier configuration
will remain unchanged.
To restore these parameters to the factory default settings:
1. Press and hold the RTFM switch for 20 seconds.
2. The loudspeaker amplifier will beep after one second. Continue to hold the switch until the
loudspeaker amplifier beeps again after 20 seconds.
3. Release the switch. The following occurs:
•
A voice message announces that the factory default settings are being restored.
•
Once the settings are restored, a voice message announces the restored default IP address:
192.168.3.10
•
A voice message announces that the loudspeaker amplifier is rebooting.
•
The loudspeaker amplifier reboots.
Table 2-13. Factory Default Settings
Parameter
Factory Default Setting
IP Addressing
static
IP Address
192.168.3.10
Web Access Username
admin
Web Access Password
admin
Subnet Mask
255.255.255.0
Default Gateway
192.168.3.1
Summary of Contents for 930112A
Page 1: ...VoIP Loudspeaker Amplifier Operations Guide Wireless AC Powered Part 010860 930112A...
Page 4: ...CyberData Corporation 930112A VoIP Loudspeaker Amplifier Operations Guide...
Page 6: ...CyberData Corporation 930112A VoIP Loudspeaker Amplifier Operations Guide Contents ii...
Page 10: ...CyberData Corporation 930112A VoIP Loudspeaker Amplifier Operations Guide Product Overview 4...
Page 42: ...CyberData Corporation 930112A VoIP Loudspeaker Amplifier Operations Guide 36...