Operations Guide
931384A
CyberData Corporation
Installing the Secure Access Control Keypad
Secure Access Control Keypad Setup
48
2. On the
Sensor
page, enter values for the parameters indicated in
.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the
Toggle Help
button is pressed
.
Table 2-16. Sensor Configuration Parameters
Web Page Item
Description
Door Sensor Settings
Door Sensor Normally Closed
Select the inactive state of the door sensor. The door sensor is
also known as the Sense Input on the device's terminal block.
Buzz on Door Open Timeout
When selected, the buzzer will beep until the on board sensor is
deactivated.
Door Open Timeout (in seconds)
The time (in seconds) the device will wait before it performs an
action when the on-board door sensor is activated. The action(s)
performed are based on the configured Door Sensor Settings
below. Enter up to 5 digits.
Activate Relay
When selected, the device's on-board relay will be activated until
the on-board door sensor is deactivated.
Make call to extension
When selected, the device will call an extension when the on-
board door sensor is activated. Use the
Dial Out Extension
field
below to specify the extension the device will call.
Dial Out Extension
Specify the extension the device will call when the on-board door
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID
An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Repeat Sensor Message
The number of times to repeat the audio message through the
local speaker or to the remote endpoint. A value of 0 will repeat
forever. Enter a value from 0-65536.
Intrusion Sensor Settings
Activate Relay
When selected, the device's on-board relay will be activated until
the intrusion sensor is deactivated.
Make call to extension
When selected, the device will call an extension when the
intrusion sensor is activated. Use the
Dial Out Extension
field
below to specify the extension the device will call.
Dial Out Extension
Specify the extension the device will call when the intrusion
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID
An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Repeat Intrusion Message
The number of times to repeat the audio message through the
local speaker or to the remote endpoint. A value of 0 will repeat
forever. Enter a value from 0-65536.
Click the T
est Door Sensor
button to test the door sensor.
Click the T
est Intrusion Sensor
button to test the Intrusion
sensor.