background image

© 2014, CyberData Corporation, ALL RIGHTS RESERVED

930925A

Quick Reference 

Quick  Reference 

930925A

© 2014, CyberData Corporation, ALL RIGHTS RESERVED

Dimensions (Rear View and Mounting Holes)

Terminal Block Connections

Call Button

Features

Dimensions (Front and Side View)

Microphone 

Hole

Speaker 

Drain Hole

1.690

[85.85]

0.869 [22.07]

0.869 [22.07]

3.380 [85.85]

1.690

[42.93]

[42.93]

3.380

Dimensions are in Inches [Millimeter]

ø0.280 [ø7.11]

ø0.854 [ø21.69]

(4 Places)

J3 Terminal Block

Wire (IN)

can accept 16 AWG wire

*Contacts 1 and 2 on the J3 terminal block are only for 
powering the Intercom from a non-PoE 12VDC power 
source as an alternative to Network PoE power. Use of 
these contacts for any other purpose will damage the 
Intercom and void the product warranty.

Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground

2 = Power Ground*

1 = 8 to 12 VDC at 1000 mA*

3

4

Alternate Power Input:

7 = Reserved for Future Use
8 = Reserved for Future Use

1

8

Use a 3.17 mm (1/8-inch) flat blade 

screwdriver for the terminal block screws 

RTFM Button

Side Conduit Network Cable Entry Restrictions

Rear Conduit Network Cable Entry Restrictions

RTFM

When the device is operational and linked to a network, 
you can use the Reset Test Function Management 
(RTFM) button (SW1 [see picture]) to announce the 
device’s IP address or restore the device to the factory
default settings.

To announce the device’s current IP address:

Press and release the RTFM button within a five 

second window.

Note

The device will use DHCP to obtain the new IP 
address (DHCP-assigned address or default to 
10.10.10.10 if a DHCP server is not present).

To restore the device to factory default settings: 

Press and hold the RTFM button for longer than five 

seconds until you hear the device announce that it is 
restoring the factory default settings.

Spacer

5/32"

(Not Provided)

1/2" Conduit

1/2" Set Screw

(Not Provided)

Connector

Assembly

Hole Plug

Network

Cable

(Not Provided)

Gap

*More installation and mounting 
information is illustrated in the 
Operations Guide.

1/2" Conduit

(Not Provided)

Here

Connector

1/2" Conduit

(Not Provided)

Cable

Network

Spacer

Add

(Not Provided)

Cable

Network

(Not Provided)

1/2" Conduit

1/2" Conduit

Spacer

Connector

(Not Provided)

(Not Provided)

Here

Add

With Shroud

Without Shroud

VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299