2.2.5 Confirm Operation
After connecting the Paging Amplifier to the ethernet hub, use the LEDs on the Paging Amplifier face
to confirm that the Paging Amplifier is operational and linked to the network.
LED
Color
Function
Power
Blue
/Green
The power LED is illuminated a steady green when the power is on and in
low power mode. The power LED is illuminated a steady
blue
when the
amplifier is in high power mode. The power LED will blink during a boot up or
a phone call.
Status
Green
After supplying power to the Paging Amplifier, a steady LED confirms that
the Paging Amplifier is operational. The status LED will blink during a page
when it is online.
Link
Green/Yellow
The Link LED is illuminated green for a 10Mb link or yellow/green for a
100Mb link when the network link to the Paging Amplifier is established.
Activity
Green
The Activity LED blinks to indicate network traffic.
Figure 2-12. Paging Amplifier LEDs—Power and Link
Figure 2-13. Paging Amplifier LEDs—Status and Activity
Table 2-7. Paging Amplifier LEDs