background image

i

Table of Contents

Safety Instructions .................................................. 1
Part Identification .................................................... 2

Enclosure Components .....................................................2
Hardware and Accessories................................................2

Initial Enclosure Setup............................................ 3

Door and Side Panel Locks ...............................................3
Remove and Reverse Front Door......................................3
Relocate CyberPower Badge ............................................4
Open and Remove Side Panels ........................................5
Adjusting Rack Angles.......................................................5

Mounting Depth ............................................................................ 5
Dual Mounting Holes .................................................................... 6

Cable Access.....................................................................7
Grounding ..........................................................................7

Enclosure Installation ............................................. 8

Mounting on Wall ...............................................................8
Caster Installation ..............................................................9

Equipment Installation.......................................... 10

Mounting Using Square Holes .........................................10
Mounting Using Threaded Round Holes..........................11

Summary of Contents for CR U6 Series

Page 1: ...Systems Inc All rights reserved USER S MANUAL Wall Mount Enclosure CRxU6 Series Wall Mount Enclosure CRxU6 Series SAVE THESE INSTRUCTIONS Please read this manual and follow the instructions for installation and use K01 0000577 01 ...

Page 2: ...Panel Locks 3 Remove and Reverse Front Door 3 Relocate CyberPower Badge 4 Open and Remove Side Panels 5 Adjusting Rack Angles 5 Mounting Depth 5 Dual Mounting Holes 6 Cable Access 7 Grounding 7 Enclosure Installation 8 Mounting on Wall 8 Caster Installation 9 Equipment Installation 10 Mounting Using Square Holes 10 Mounting Using Threaded Round Holes 11 ...

Page 3: ...visible damage Before installing the enclosure ensure that the wall or the floor is even and capable of supporting the total load being installed in the enclosure including the enclosure itself Do not mount the enclosure to the wall with equipment installed in it Do not stack enclosures and do not put any objects on the top of the enclosure Keep the enclosure in an appropriately ventilated space a...

Page 4: ... 5 Depth Adjustable Rack Angles with Dual Mounting Holes 6 Horizontal Rails 7 Enclosure Mounting Keyholes 8 Back Panel Hardware and Accessories Expansion Bolt 4 M6 Cage Nuts 30 M6 Phillips Head Screw Black 30 Key 2 Cup Washer 30 12 24 Screw Silver 30 Part Identification 1 2 3 4 7 6 5 8 Enclosure Components Model CR6U61001 is shown ...

Page 5: ...ection before mounting the enclosure on the wall Door and Side Panel Locks The door and side panel locks are keyed alike The lock locations are shown below Use the included keys to operate the locks NOTE The enclosure is shipped with the door locked To access the keys in the accessories bag open a side panel by pushing the black retention tabs inward as shown on page 5 Side panels are shipped unlo...

Page 6: ... pin hinges into the hinge holes on the enclosure as shown below Relocate CyberPower Badge To relocate the CyberPower badge pull the two parts apart as shown below To re install the badge measure the vertical and horizontal distance from the edge of the door as shown below and push both parts together NOTE Please press hard to make sure the badge has been firmly installed 3 76mm 9 84 250mm ...

Page 7: ...d by unscrewing them from the horizontal mounting rails Move the cage nuts behind the upper and lower horizontal rails to the desired depth as shown below Depth of the rack angles can be adjusted in 3 4 20mm increments NOTE Verify the rack angles are installed at the correct depth before installing equipment in the enclosure You may remove the two rear rack angles if only installing two post mount...

Page 8: ...the square hole position Square holes 12 24 threaded round holes To use the side with the threaded holes unscrew the rack angles from the horizontal mounting rails Switch the rack angles to the opposite side of the enclosure while ensuring that the rack unit numbers face outward Screw the rack angles to the horizontal mounting rails Keep the desired mounting depth when switching the rack angles ...

Page 9: ...uring the cover as shown below Grounding An individual grounding connection per enclosure is strongly recommended Failure to follow may result in serious injury or death To connect the enclosure to the facility s ground use the grounding nut in the enclosure The grounding point is marked in the enclosure with the ground symbol shown below WARNING ...

Page 10: ... total load being mounted in the enclosure including the enclosure itself Make sure the enclosure is properly mounted to the wall before installing equipment in the enclosure Do not mount the enclosure with equipment installed in it Use the included expansion bolts or other appropriate mounting hardware to mount the enclosure to the wall as shown below WARNING WARNING The enclosure is a heavy obje...

Page 11: ... s Wall Mount Enclosures are compatible with an optional caster kit CRA60002 shown below Please contact your sales representative for ordering information NOTE For installation information please see the CRA60002 quick start guide 9 ...

Page 12: ... before installing in the enclosure Equipment Installation Verify that the enclosure is securely mounted to the wall prior to installing any equipment It is strongly recommended to first install equipment in the bottom of the enclosure Heavier equipment should be installed in the bottom of the enclosure If using sliding rails with installed equipment use caution when pulling the equipment out of t...

Page 13: ... the included silver 12 24 mounting screws into the threaded holes as shown below 5 6 4 2 Install the equipment by screwing the included black M6 screws and cup washers into the cage nuts as shown below 5 6 4 For warranty and additional information please visit www cyberpower com ...

Page 14: ...om For USA and Canada 4241 12th Ave East Suite 400 Shakopee MN 55379 Toll free 877 297 6937 For all other regions Please visit our website for local contact information Copyright 2017 Cyber Power Systems Inc All rights reserved K01 0000577 01 ...