5
•
Connect the power cable to the 12V adapter cable.
•
You may cut the cable of the 12V adapter to connect it directly to the power cable or use an
adapter cable in the middle.
•
The maximum power consumption of the product is 1A at the power supply of 12V.
Terminal 1
Terminal 2
Door-Lock Device
(Deadbolt, EM Lock)
12V Separate
Power Supply
Exit Button
Exit Button
▶Door-Lock Cable
1 Yellow : Exit Button (Input)
2 Yellow : Exit Button (GND)
3 Not Used
4 Black : Relay (NC)
5 Black : Relay (COM)
EM Lock
Deadbolt
Exit Button
Exit
Button
▶ Power Cable
1 Red : 12V
2 Black : GND
▶
Door-Lock Cable
1 Yellow : Exit Button (Input)
2 Yellow : Exit Button (GND)
3 Not Used
4 Black : Relay (NC)
5 Black : Relay (COM)
•
The door lock cable is for connecting the door lock (deadbolt, EM lock) and EXIT-button.
•
Connect the yellow line of the door lock cable and the exit button.
•
Connect the black line of the door lock cable to the exit button of the door lock.
•
The power of the door lock must be supplied separately to suit the rated power of the door
lock.
•
Depending on the position of the door lock, the cable must be extended.
•
If you finished connecting the power and door lock cables, open the cover on the rear of
the product and connect them to the appropriate connectors.
•
In addition, when connecting to the Manager server, the ethernet cable must be connected
to the RJ45 LAN-port.
•
After connecting the cables, organize then close the cover.
▶
Power Cable Connection
1 Red : 12V
2 Black : GND
1
2
3
4
5
6
9
10
11
7
8
Cable Connection
1.3