ROOM SIZE REQUIREMENTS
•
3.5Kw Version - The Fire Line must not be fitted in an internal space of
less than 40m³ in volume.
•
2.7Kw Version - The Fire Line must not be fitted in an internal space of
less than 27m³ in volume.
•
Adjoining spaces, not separated by a door may be included.
•
To convert cubic feet (ft³) to cubic metre (m³) divide the room volume
in cubic feet by 35.3.
OTHER REQUIREMENTS
The fire must not be fitted in basements which are not open on at least
one side (an open-able window), bathrooms or in corridors, stairways,
landings or hallways of multi occupancy dwellings, garages or rooms
containing petroleum products.
Although the installation of our Flueless fires in bedrooms is permitted,
CVO Fire does not recommend it - if in doubt please refer to BS5871 2007
for details or contact CVO Fire for further advice.
Soft furnishings, decorations and wall coverings etc. must not be placed
within 1.5 metres of the appliance and its outlets. See Image
Be aware of curtains etc. that could be blown towards the appliance.