Anti-static handling guidelines 

 
Make sure that electrostatic handling precautions are taken immediately before handling PCBs and other 

static sensitive components. 
 

Before handling any static-sensitive items, operators should get rid of any electrostatic charge by 
touching a sound safety earth.  Always handle PCBs by their sides and avoid touching any components. 

  

4.1

 

Unpacking the ViAC-RTK 

 

Remove the equipment from its packing, and check the contents against the following list: 

 

ViAC-1ZC- 1 zone controller. 

 

ViAC-CPP- Ceiling Pull Cord. 

 

ViAC-ODP- Overdoor Indicator Plate. 

 

ViAC-CNP- Cancel Plate. 

 

Accessible WC Sticker. 

 

Instruction Sticker (to be located within the WC). 

 

Installation and operation manual. 

 

Accessory pack with the following contents:- 

o

 

8 number device 2 part terminals. 

o

 

8 no device mounting screws. 
 

 

Installation 

4.2

 

Connecting the ViAC-RTK Assist Call remote kit 

 

The ViAC-1ZC controller mounts onto a 25mm UK double gang back box , 

the ViAC-CCP, ViAC-ODP and 

ViAC-CNP device plates mount onto a 25mm UK single gang back box. 

 

 

 

 
 

 

The devices are wired to the terminals marked Line 0 and +, the devices are polarity sensitive, cabling 
between the controller and the devices is 2 core 1 mm CSA  flex, wired in a radial circuit. 
 

All system wiring should be installed to meet the appropriate parts of BS 7671 (Wiring Regulations). 
Other national standards of installation should be adhered to where applicable. 

Extra Low Voltage (ELV) Wiring:-  Always segregate low voltage wiring from the main wiring 

Summary of Contents for ViAC-RTK

Page 1: ...Assist Call ViAC RTK Remote Emergency Assistance Kit Installation and Operation Manual Version 2 August 2020...

Page 2: ...l reset point location 3 4 Important Safety Information 4 4 1 Unpacking the ViAC RTK 5 Installation 5 4 2 Connecting the ViAC RTK Assist Call remote kit 5 4 3 Additional Functions 6 4 3 1 Buzzer Volum...

Page 3: ...call devices can be wired in any order so wiring runs can be kept to a minimum The Assist Call system wired from a 1 zone controller features BS8300 acknowledge function this requires that visual and...

Page 4: ...ment is defined as Class 2 in EN60950 Low Voltage Directive and must be EARTHED The ViLX 1ZC 1 Zone controller requires a 3A switched fuse spur Caution Indoor Use Only Warning Shock Hazard Isolate Bef...

Page 5: ...on Sticker to be located within the WC Installation and operation manual Accessory pack with the following contents o 8 number device 2 part terminals o 8 no device mounting screws Installation 4 2 Co...

Page 6: ...ng plate will indicate steady blue and the blue indicator flash and sounder will activate on the cancel plate 4 4 2 Indication outside the WC The overdoor indicator plate will flash and sounder will a...

Page 7: ...nance agreement be in place for the EVCS The maintenance schedule should be as follows Frequency Test Monthly Test the system monthly by operating a pull cord acknowledge the call using the controller...

Page 8: ...8 Notes The Lexicomm ViLX RTK is designed and manufactured in the UK by Vox Ignis Limited Unit 27 NEBIC Enterprise Park East Sunderland SR5 2TA Company Registration No 8892407 www vox ignis com info...

Reviews: