MAINTENANCE
CUTTER 24V 86039080 04/17/07
4-4
CHECKING BATTERY SPECIFIC GRAVITY
Use a hydrometer to check the battery specific
gravity.
CHECKING GRAVITY
A. Hydrometer
B. Battery
NOTE: Do not take readings immediately after
adding distilled water, if the water and acid are not
thoroughly mixed, the reading may not be accurate.
Check the hydrometer readings against this chart.
SPECIFIC GRAVITY
@ 80
°
F (27
°
C)
BATTERY CONDITION
1.265 100%
CHARGED
1.225 75%
CHARGED
1.190 50%
CHARGED
1.155 25%
CHARGED
1.120 DISCHARGED
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80
°
F
(27
°C), the reading must be temperature corrected.
To find the corrected specific gravity reading when
the temperature of the battery electrolyte is other
than 80
°F (27°): Add (+) to the specific gravity
reading 0.004 (4 points), for each 10
°F (6°C) above
80
° (27°C).
Subtract (-) from the specific reading 0.004 (4
points), for each 10
°F (6°C) below 80°F (27°C).
TO CHARGE THE BATTERIES
When servicing machine, avoid contact with
battery acid.
Batteries emit hydrogen gas. Explosion or fire
can result. Keep sparks and open flame away.
Keep covers open when charging.
Wear eye protection and protective clothing
when working with batteries.
Charge batteries in a well ventilated area. Leave
the battery cover open.
Use a 24 volt, 18 amp maximum output or 25 amp
(depending on the size of the batteries), DC charger
which will automatically shut off when the batteries
are fully charged.
1.
Stop the machine in a clean, well ventilated area
next to the charger.
2.
Turn “OFF” machine.
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, turn off machine
and remove key.
3.
Raise the battery cover.
Batteries emit hydrogen gas. Explosion or fire
can result. Keep sparks and open flame away.
Keep covers open when charging.
4.
Check the electrolyte level in each battery cell.
Before charging, add just enough distilled water
to cover the plates. After charging is complete,
add just enough distilled water to bring up the
level to the indicator ring. If the water level is
too high before charging, normal expansion rate
of the electrolyte may cause an overflow.
Resulting in a loss of battery acid balance and
damage the machine.
!
WARNING
!
CAUTION
!
WARNING
!
WARNING
!
WARNING
Battery Check
Summary of Contents for BSCSCX264
Page 12: ...CONTROLS CUTTER 24V 86039080 04 17 07 3 5 3 5 8 6 13 9 2 12 11 15 1 14 7 10 4 16...
Page 34: ...CONTROL HANDLE CUTTER 24V 86039080 04 17 07 5 1 11 9 6 10 8 7 4 5 2 3 1...
Page 36: ...COVER FRONT TANK MOUNT CUTTER 24V 86039080 04 17 07 5 3 10 9 8 7 5 1 2 6 2 3 3...
Page 38: ...COVER TOP TANK MOUNT CUTTER 24V 86039080 04 17 07 5 5 8 5 7 1 2 3 4 3 5 3 6 3 9 11 10...
Page 40: ...DECAL CUTTER 24V 86039080 04 17 07 5 7 1 2 3 5 6 7 4...
Page 44: ...LIFT HANDLE CUTTER 24V 86039080 04 17 07 5 11 8 6 1 7 2 1 9 4 5 3...
Page 56: ...SCRUB DECK MOTORS CUTTER 24V 86039080 04 17 07 5 23 8 6 7 9 10 4 5 3 2 1...
Page 72: ...SOLUTION CUTTER 24V 86039080 04 17 07 5 39 7 2 3 8 4 10 9 1 5 13 12 11 10 4 6...
Page 80: ...VACUUM CUTTER 24V 86039080 04 17 07 5 47 4 15 1 5 6 10 9 5 4 11 12 14 3 2 13 7 8...
Page 82: ...WHEELS AND FRAME CUTTER 24V 86039080 06 29 11 5 49 6 8 7 9 10 1 2 5 4A 4C 3 4B 11 4E 4D...
Page 84: ...WIRING BATTERY CUTTER 24V 86039080 04 17 07 5 51 1 2 3 4 5 9 6 7 8 1 11 10 12...
Page 94: ...EMERGENCY STOP OPTION CUTTER 24V 86039080 04 17 07 5 61 1...
Page 98: ...BATTERY CHARGER SCC326 CUTTER 24V 86039080 04 17 07 5 65...
Page 101: ...CUTTER 24V 86039080 04 17 07 5 68...
Page 102: ...CUTTER 24V 86039080 04 17 07 5 69...