D. Instantaneous current and to improve power ratio, it should be fitted the A.C.L. to R.S.T.
input side under the following circumstance:
a. Where power supply capacity is larger than 500 KVA.
b. Using thyrister, phase advance capacitor etc. from the same power supply.
A.C.L. Specifications table:
Voltage (V)
Model
Current
(Ar.m.s)
Induction
Value
CT2002ES-A75
6A
1.8mH
CT2002ES-1A5
10A
1.1mH
CT2002ES-2A2
15A
0.71mH
CT2002ES-3A7
20A
0.53mH
220
CT2004ES-1A5
5A
4.2mH
CT2004ES-2A2
7.5A
3.6mH
CT2004ES-3A7
10A
2.2mH
380
/
460
Notes: The A.C.L. for 220V and 380V/460V have different induction values, please does
not mix up.
E. Brake resistor standard of usage
CT2000ES series inverter contain brake resistor
,
P
、
PR terminal can connect external
brake resistor. The sizes of brake resistors take the table for reference.
If inertia is too large or cycle of discharge is higher, user can increase wattage of resistor.
Voltage (V)
Type
Brake resistor
standard
Mark
CT2002ES-A75
120
Ω
80W
CT2002ES-1A5
80
Ω
160W
CT2002ES-2A2
60
Ω
250W
CT2002ES-3A7
36
Ω
400W
220
CT2004ES-1A5
360
Ω
300W
CT2004ES-2A2
250
Ω
500W
CT2004ES-3A7
150
Ω
800W
380
/
460