Custom Dynamics TruFlex TF5 Installation Instructions Manual Download Page 4

Installation Instructions 

-

 Page 4

 

Questions? Call us at:  1 (800) 382

-

1388    M

-

TH  8:30AM

-

5:30PM / FR  9:30AM

-

5:30PM EST

 

06

-

2016SM

 

Universal Integrated Run/Turn or Run/Brake/Turn TruFLEX® 3 section Amber/Red/Amber

 

Left Turn = Amber

 

B

lack

 = L

E

D G

ro

un

d

 

Y

ell

o

w

 = 

Le

ft 

T

ur

n

 

V

eh

icl

e

 G

ro

u

nd

 

V

eh

icl

e

 L

e

ft T

u

rn

 

Right Turn = Amber

 

Center Brake = Red

 

Part Numbers:

 

3 Section

 

Amber/Red/Amber:

 

TF40ARC

 

TF40ARS

 

TF115ARC

 

Use weatherproof splice 
connectors or Posi

-

taps

™ 

for connections or solder 
wire connections. 

 

Make sure to insulate solder 
connections with heat 
shrink tubing or electrical 
tape. 

 

*Diagram Shows wiring as 
Run/Brake/Turn with TFC 
Dual Converter. 

 

V

eh

icl

e

 Rig

ht 

T

ur

n

 

TFC 

 

Dual 

 

Converter

 

= Connection Points

 

Red

 =

 Ce
nte

r B

ra

ke

 

Red

 =

 B

ra

ke

 

Orange = Running 

 

V

eh

icl

e

 B

ra

ke

 

V

eh

icl

e

 Ru
nn

in

g

 

*For Single function on Brake, 
Omit the Dual Converter. Cap any 
unused wires to prevent shorting.

 

3 Section

 

Red/Red/Red:

 

TF115RC 

 

TF115RR 

 

TF115RS 

 

 

Left Turn = Red

 

B

lack

 = L

E

D G

ro

un

d

 

Red

 =

 L

e

ft T

u

rn

 

V

eh

icl

e

 G

ro

u

nd

 

V

eh

icl

e

 L

e

ft T

u

rn

 

Right Turn = Red

 

Center Brake = Red

 

Part Numbers:

 

Use weatherproof splice 
connectors or Posi

-

taps

™ 

for connections or solder 
wire connections. 

 

Make sure to insulate solder 
connections with heat 
shrink tubing or electrical 
tape. 

 

*Diagram Shows wiring as 
Run/Brake/Turn with TFC 
Dual Converter. 

 

*Some models may have 
individual ground wires for 
each board section. 

 

V

eh

icl

e

 Rig

ht 

T

ur

n

 

TFC 

 

Dual 

 

Converter

 

= Connection Points

 

Red

 =

 Ce
nte

r B

ra

ke

 

Red

 =

 B

ra

ke

 

Orange = Running 

 

V

eh

icl

e

 B

ra

ke

 

V

eh

icl

e

 Ru
nn

in

g

 

*For Single function on Brake, 
Omit the Dual Converter. Cap any 
unused wires to prevent shorting.

 

*Dual Converters may be applied 
to left and right turn sections for 
low high operation. Scenario not 
shown.

 

Red

 =

 L

e

ft T

u

rn

 

Universal Integrated Run/Turn or Run/Brake/Turn TruFLEX® 3 section Red/Red/Red

 

Y

ell

o

w

 = Ri

gh

t T

ur

n

 

Reviews: