15
2.
Close air vent on burner adjustment band.
3.
Loosen the flare nuts and remove the fuel line between the solenoid valve
and nozzle pipe. Set aside.
Caution! Be careful not to drop the nut into
the air vent!
4.
Remove nozzle pipe retaining nut from nozzle pipe and set aside.
5.
Loosen the coil clamp located on the other side of the coil and open the
burner lid. Carefully slide the nozzle pipe assembly downward and out
until the assembly becomes free and lifts out.
Caution! Be careful not to damage the ceramic insulators on the electrodes.
6.
Replace the nozzle with the desired size.
7.
Reset the electrodes or replace if damaged.
8.
Replace the nozzle pipe assembly. Re-assemble all components by
reversing the disassembly procedures. Open air band on the burner
assembly. Make air adjustments following set-up procedures.
BE CAREGUL NOT TO MOVE ELECTRODE SETTINGS