Custo Med Bicycle Ergometer ec3000e Operating Manual Download Page 29

- 29 -

 

 

 

 

 

 

 

 

Use the right and left softkeys 

↑ ↓

 to select the parameter 

to edit.

When confirmed with SELECT, the corresponding value ap‑
pears in reverse video and can be changed with the arrow 
keys 

↑ ↓

.

Pressing SELECT will save the new value.

All other parameters are edited in the same way.

You exit the configuration with 

.

C

ontrast

The display contrast is adjustable in the range from 
0 to 100%.

l

oaD

 C

hanGe

Here you determine the increments for each load change. 
Depending on your choice, each key press will change the 
load by +/‑ 1, 5, 10 und 25 Watts.

s

electing

 

the

 

parameter

 

to

 

edit

Protocol 

 

6.

Select 

 

Step 

Basic Load 

 

25 W 

Stage Time 

 

     2 min 

Load Stage   

25 W 

 

Select

e

diting

 

the

 

parameter

 

value

Protocol 

 

6.

Select 

 

Step 

Basic Load 

 

25 W 

Stage Time 

 

     2 min 

Load Stage   

25 W 

 

Select

a

djusting

 

the

 

display

 

contrast

Load Change
+/-  

1  Watt 

+/- 

5 Watt 

+/- 

10 Watt 

+/- 

25 Watt 

 

Select

Contrast

 

50 %

 

Select

s

electing

 

the

 

increment

 

for

 

manual

 

load

 

changes

Summary of Contents for Bicycle Ergometer ec3000e

Page 1: ...GEB 0179 DK 1334 Version 001 12 09 2013 Operating manual Bicycle Ergometer ec3000e...

Page 2: ...in this manual All trademarks appearing in this document are trademarks of their respective owners Their protection is acknowledged No part of this manual may be reprinted translated or reproduced wi...

Page 3: ...ting the Blood Pressure Cuff 17 Preparing the Patient 18 Adjusting the Saddle and the Handlebar 18 Preparing the Patient for Blood Pressure Measurements 19 Checking the Cuff Tubing 20 Attaching the Sp...

Page 4: ...4...

Page 5: ...ind 17008 HF Empf nger POLAR 17009 HF Empf nger Digital bmi 17010 Puls Brustgurt Digital bmi 17011 Pedalkurbeln verstellbar mit den Anforderungen der Richtlinie bereinstimmt is in conformity with the...

Page 6: ...6...

Page 7: ...the device must read and understand the content of this manual before using or work on it Paragraphs with special symbols are of particular importance If unauthorized individuals open the control ter...

Page 8: ...ermany Tel 49 0 7431 9894 0 Fax 49 0 7431 9894 128 Email info ergoline com Internet www ergoline com Distributed by custo med GmbH Leibnizstra e 7 85521 Ottobrunn Germany Tel 49 89 710 98 00 Fax 49 89...

Page 9: ...rning Shock Hazard When the ergometer is connected to other equipment or if a medical system is created it must be ensured that the added leakage currents do not present a hazard In case of questions...

Page 10: ...easurement will be aborted and the cuff deflated If a valid measurement cannot be completed within 120 seconds the measurement will be aborted and the cuff deflated If the cuff pressure remains consta...

Page 11: ...11...

Page 12: ...Adjustment of the handlebar height ec3000e only 6 Castors 7 Speed display RPM for patient 8 Adjustment of the saddle height 9 Digital saddle height indication option 10 Power switch green button 11 S...

Page 13: ...sp the handlebar and tilt the ec3000e towards you until it is standing on the castors only and is balanced It is now possible to transport the ec3000e When you have reached the new location lower the...

Page 14: ...patient Connecting the Power Cord Set the handlebar to the front upper position and secure Tilt the ec3000e carefully towards you until it rests on the handlebar Assembly position of the ec3000e ergom...

Page 15: ...connection to the protective ground system power cords of type hospital only or hospital grade have to be used Power cord with installed strain relief The connection panel is located on the underside...

Page 16: ...og remote start etc The appropriate cable is plugged into the corresponding socket on the connection panel Port 1 USB and secured with the strain relief Hint connecting cables Only use connecting cabl...

Page 17: ...le while the blood pressure is being taken Therefore do not forget to attach the cuff tubing to the handlebar with the supplied Velcro tape Open the large Velcro tape and wrap around handlebar Secure...

Page 18: ...ting upright on the saddle can reach it easily To do so open clamping lever 1 and set the handlebar to a suitable angle On the ec3000e 200 the height of the handlebar can ad ditionally be adjusted wit...

Page 19: ...e must be located exactly on the brachial artery Locate the artery by palpation if required The red tab identifies the position of the micro phone The accurate placement of the microphone is the prima...

Page 20: ...e the cuff immediately from the arm or disconnect the cuff tubing from the control terminal The same measures are recommended if the cuff does not deflate correctly When you close the Velcro strap che...

Page 21: ...O2 Sensor Place the index finger into the SoftTip sensor The cable should run on top of the hand After some seconds the actual SpO2 value is displayed on the recorder display SpO2 Sensors option Attac...

Page 22: ...ted the initial screen of the selected operating mode e g Ergometry will be displayed instead of the main menu With the key you can display the main menu If an error message e g E 01 appears immediate...

Page 23: ...SETTINGS Used to configure the ergometer Speed readout At the top of the control terminal there is a speed readout for the patient as well as three LEDs that inform the patient of the speed too slow...

Page 24: ...the corresponding values will be displayed The exercise test can only be terminated with the corre sponding command from the controlling ECG unit Note All functions are locked while the ergometer is...

Page 25: ...cursor on one of the protocols and confirm the selec tion with SELECT The exercise test is started with the Start key a blood pressure measurement at rest may precede the test see Settings When the b...

Page 26: ...be selected manually It is recommended that the patient continues to pedal in the recovery phase The END key in the middle will terminate the test End Note The saddle height ec3000e 200 can be changed...

Page 27: ...easurements The exercise test is started with the Start key afterwards the load can be set and changed with the 5 W and 5 W keys in increments of 1 W up to 25 W as config ured Blood pressure measureme...

Page 28: ...the ergometer will display this menu Use the softkeys on the right and left to position the bar cursor on your preferred default mode and save the selection with SELECT Protocols Protocols 6 15 are us...

Page 29: ...le in the range from 0 to 100 Load Change Here you determine the increments for each load change Depending on your choice each key press will change the load by 1 5 10 und 25 Watts Selecting the param...

Page 30: ...in with you select DATE or TIME and confirm the selection Then the value displayed in reverse video can be edited with the keys and saved with SELECT The time is adjusted in the same way You exit the...

Page 31: ...be initiated with digital commands Digital default The communication with the ergo meter is entirely controlled with digital commands Analog IN OUT The entire communication load control and BP mea sur...

Page 32: ...ipping wet If the cleaning agents and disinfectants used are caustic or contain alcohol they may damage and or discolor the upholstery Only the following disinfectants are approved Sch lke Mayr GmbH A...

Page 33: ...or soap water Allow the microphone to dry before reinserting it in its pocket For disinfection spray a disinfectant sparingly on the cuff the tubing and the microphone After the contact time indicated...

Page 34: ...of SoftTip Sensor 1 The sensor must be carefully cleaned or disinfected after every use and before use with a different pa tient It is recommended that sensors be prepared for reuse immediately after...

Page 35: ...dried with sterile compressed air Inspection and function test Visually inspect the sensors for damage Worn deformed porous or otherwise damaged sensors must not be reused Cleaning of cables Disconne...

Page 36: ...o years according to the rules of the art by a Service Engineer authorized by custo med Similarly the automatic sphygmomanometer in the control terminal must be checked and calibrated by an authorized...

Page 37: ...ured Load to DIN VDE 0750 0238 Load Increments user programmable Internal Protocols Control Terminal 5 fixed incremental exercise test protocols e g WHO 10 user programmable protocols manual load cont...

Page 38: ...30 to 75 no condensation atmospheric pressure 700 to 1060 hPa transport and storage temperature 20 to 70 C 40 to 158 F rel humidity 10 to 90 no condensation atmospheric pressure 500 to 1060 hPa Blood...

Page 39: ...n and comparison of the rest ing BP readings from both methods for plausibility Exercise Test Protocols Protocol initial load W time in stage min load increment W recovery load W recovery time min 1 W...

Page 40: ...range black speed independent range to DIN VDE 0750 0238 black grey speed independent range of the ec3000e ergometer Family of characteristics of the load periods according to IEC 60601 1 Under perman...

Page 41: ...operation in the configuration in which it is being used Guidance and Manufacturer s Declaration Electromagnetic Emissions The ergoselect ergometer is intended for use in the electromagnetic environme...

Page 42: ...differential mode 2 kV common mode 1 kV 2 kV Mains power should be that of a typical commer cial or hospital environment Voltage dips short interrup tions and voltage variations on power supply input...

Page 43: ...from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment mark...

Page 44: ...t Power of Transmitter W Separation Distance According to Frequency of Transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0...

Page 45: ......

Page 46: ...custo med GmbH Leibnizstra e 7 85521 Ottobrunn Germany Phone 49 89 710 98 00 Fax 49 89 710 98 10 Email info customed de Internet www customed de...

Reviews: