The CLI is also accessible via Ethernet using Secure Shell (SSH). The default IP addresses are
shown in Table 6.1.
Simple Network Management Protocol (SNMP) is also available to communicate with the CNS4.
See
Simple Network Management Protocol
section for details.
6.2.2.1
Terminal Emulation
A copy of the PuTTY terminal emulator can be obtained from
https://www.putty.org/
.
This section explains setting up communications using serial communication (RS-232) and a
PuTTY terminal emulator.
1. If not previously accomplished, download a copy of the PuTTY terminal emulator and install on
computer.
2. Open PuTTY terminal emulator (Figure 6.2).
Figure 6.2
PuTTY Terminal Emulator
3. Configure PuTTY as follows:
•
Serial line: COM1
•
Speed: 115200
•
Connection type: Serial
4. Click
Open
button.
A terminal screen should activate.
Table 6.1
Ethernet Interfaces
Connector
Port
Interface
IP Address
Subnet Mask
GBE0
Port 0
eth0
192.168.0.1
255.255.255.0
GBE1
Port 1
eth1
192.168.1.1
255.255.255.0
GBE2
Port 2
eth2
192.168.2.1
255.255.255.0
GBE3
Port 3
eth3
192.168.3.1
255.255.255.0