Operation
Revision 1.0
Operation
6.1
Lab Setup / Connections
NOTE
If the optional lab cables are not used, the user must construct a connection method for their test
set up. Refer to paragraph B.1
and paragraph B.2
for connector and
signal information.
NOTE
The CNS4 is powered by a user-supplied 28 VDC power supply and does not have a power switch
of its own. The CNS4 is powered up by turning on the 28 VDC supply.
NOTE
Anytime the CNS4 is powered off, the user must wait at least 30 seconds to re-apply power. This
gives the internal 5 second holdup capacitor circuit time to discharge properly.
1. If not previously accomplished, connect the following cables to the CNS4 front panel
connectors (Figure 6.1).
•
Power / RS-232 lab cable: Power
•
Ethernet lab cable (keyed for GBE0): GBE0
•
Ethernet lab cable (keyed for GBE1): GBE1
•
Ethernet lab cable (keyed for GBE2): GBE2
•
Ethernet lab cable (keyed for GBE3): GBE3
Figure 6.1
CNS4 Test Setup
Power Supply
CNS4
POWER / RS-232
GBE0
GBE1
GBE2
GBE3
Zeroize
Chassis
GND
Reserved
5
2
1
DDOC0108-0025
Test PC
1
2
3
4
5
6
7
8
9
10
11
12
13
1
2
3
4
5
6
7
8
9
10
11
12
13
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
28 VDC
28 VDC RTN
Similar to GBE0
Similar to GBE0
Keyed for GBE1
Keyed for GBE2
Not Used
Keyed for GBE0
Ethernet Patch Cable
Ethernet Patch Cable
Ethernet Patch Cable
Serial
Data
Port
Ethernet
Ports
AA+
AA-
AB+
AB-
AC+
AC-
AD+
AD-