background image

1

Important Safeguards/Symbols

Models Included

• WB5N

• WB5NL

Service Manual – WB5N Water Boiler

W

ilbur

 C

urtis

 C

ompany

, i

nC

.

Symbols:

WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements

This equipment is designed for commercial use. Any servicing other than cleaning and routine 

maintenance should be performed by an authorized Wilbur Curtis Company service technician.

•   DO NOT immerse the unit in water or any other liquid

•   To reduce the risk of fire or electric shock, DO NOT open service panels. There are no user 

serviceable parts inside. 

•   Keep hands and other items away from hot areas of the unit during operation.

•   Never clean with scouring powders or harsh chemicals.

CAUTION: 

DO NOT 

connect the unit to 

hot water supply. 

The inlet valve is not rated for 

hot water.

CAUTION: 

Follow 

this setup procedure 

before attempting 

to use this unit. Failure to 

follow these instructions can 

result in injury and/or void of 
warranty.

ISO 9001:2008 REGISTERED

WILBUR CURTIS CO.

6913 Acco Street,

  Montebello, CA 90640-5403

For the latest information go to 

www.wilburcurtis.com

Tel: 800/421-6150

Fax: 323/837-2410

CAUTION: 

Equipment must be 

installed to comply 

with applicable federal, state, 

and local plumbing/electrical 

codes.

INSTALLATION

This Curtis unit is pre-set and ready to go from the factory. 
System Requirements:

  • Water Supply   20 – 90 PSI (MINIMUM FLOW RATE of 2 GPM)*
  • Electrical: See electrical schematic.

3. Connect the unit to electrical outlet with appropriate amperage rating (See serial tag on ma

-

chine).

4. Once power has been supplied to the unit, flip the toggle switch to the ‘ON’ position (located on 

the rear of the unit), the water tank will begin to fill. When the water level in the tank reaches the 

probe, the heating element will turn on. 

5. Durring the initial setup, the heating tank will reach operating temperature in 60 to 70 minutes 

(factory default 204°F).

* Expect flow rate from hot water faucet to be 1 GPM from WB5N and 2 GPM from WB5NL

NSF requires the following water connection:

1.  A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so 

that the unit can be moved for cleaning.

2.  This unit must be installed with adequate backflow protection to comply with applicable federal, 

state and local codes.

3.  Water pipe connections and fixtures directly connected to a portable water supply shall be sized, 

installed and maintained in accordance with federal, state, and local codes.

NOTE: A water filtration system must be used to help maintain trouble-free operation. In areas 

with extremely hard water, we highly recommend the use of a Curtis approved water filter. (For 

our full line of filters, please log on to www.wilburcurtis.com) A water filtration system will greatly 

prolong the life of the unit and enhance the quality and taste of the product.

SETUP STEPS

1.  The unit should be level (left to right - front to back), on a secure surface.  
2.  Connect the water line to the water inlet fitting on the rear of the unit. Water volume going to the 

machine should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of 

two gallons per minute.

For the latest specifications and information go to www.wilburcurtis.com

Summary of Contents for WB5NL

Page 1: ...ating See serial tag on ma chine 4 Once power has been supplied to the unit flip the toggle switch to the ON position located on the rear of the unit the water tank will begin to fill When the water l...

Page 2: ...n is running the display shows the LED bars chasing from left to right ERROR CODES ERR1 Overflow Water level error ERR2 Open sensor Break in temperature thermistor circuit ENERGY SAVER The Energy Save...

Page 3: ...LY AGITATION HARNESS ASSEMBLY DV WB5N WB5NL TRANSFORMER 120VAC 12VAC 500mA W PIGTAIL WIRES TRIM EDGE GUARD CHROME KIT MINI UNIVERSAL CONTROL MODULE 120VAC W LABEL RELAY SOLIDSTATE 40A W INTEGRATED HEA...

Page 4: ...WC 5502 01 KIT FRONT COVER WB5N WB5NL GROMMET RUBBER 0 89 ID BUSHING PLASTIC 1 375 OD SHANK FAUCET NUT UNION SHANK FAUCET LOCKING NON LOCKING HOT WATER C RING 917 x 760 x 090 LOCK NUT 1 2 14 NPSM FIT...

Page 5: ...54339 WC 54339 101 WC 934 04 WC 4394 WC 1438 101 WC 37357 WC 522 WC 43055 WC 37266 WC 43159 WC 1939 TANK ASSEMBLY WB5N TANK ASSEMBLY WB5NL HEATING ELEMENT 220VAC 2500W GUARD SHOCK HEATING ELEMENT SENS...

Page 6: ...6 ELECTRICAL SCHEMATIC...

Page 7: ...WARRANTY DAILY CLEANING 1 Wipe exterior surfaces with a cloth soaked with a mild detergent solution Wipe off any spots dust spills or debris 2 Rinse the area with a cloth soaked with clean water remo...

Page 8: ...t the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water fl...

Reviews: