Curtis PMC 1204X/1205X/1209/1221 Manual
8
HARDWARE INSTALLATION
Fig. 7
Typical installation, Curtis PMC 1204X/1205X/1209/1221 controllers.
CONTROL
WIRING
FUSE
POWER
WIRING
FUSE
POLARITY
PROTECTION
DIODE
KEYSWITCH
POTBOX
FORWARD/REVERSE SWITCH
(SPDT, center off)
F
R
FORWARD/REVERSE
CHANGEOVER CONTACTOR
(Albright DC182 shown)
MAIN
CONTACTOR
(Albright
SW180
shown)
A1
A2
S1
S2
SERIES
MOTOR
BA
TTER
Y
B-
B+
PRECHARGE RESISTOR, such as Curtis PMC p/n MP-2
COIL SUPPRESSION DIODE, such as Curtis PMC p/n MP-1
(250
Ω
, 5W)
FWD
REV
A2
M-
B-
B+
BYPASS CONTACTOR
(
*
Pedal microswitch not used with SRO controllers.)
(
**
See Figure 10 for emergency reverse.)
COM.
N.C.
*
Bypass cont. output
REV input
Emergency reverse
**
FWD input
F/R cont. output
KSI
OTHER HARDWARE
The recommended hardware for a typical 1204X/1205X/1209/1221 controller
installation is shown in Figure 7.
Contactors should be mounted in a clean, dry location. If such a location is
unavailable, a cover should be used to deflect dirt and water splash.
The precharge resistor connected to the main contactor, and the coil
suppression diodes connected to the main contactor and to the forward/reverse
contactors, are somewhat delicate components. Care should be taken to prevent
damage to them during installation.