Is the water turned on?

Yes:

Yes:

No:

Yes:

No:

TROUBLESHOOTING INSTRUCTIONS - 

continued

DISPENSING ISSUES

TANK FILLING ISSUES

Overfilling:

Not filling:

Powder not being dispensed on any 

selection:

Verify that the wiring to the Auger Motors is 

correct.  If the wiring is correct and unbroken, 

replace the UCM UCM  (shorted wash button) or 

Membrane Control Panel (PCGT 4/5/6).

Powder not being dispensed from a single

selection:

Verify that the canister has sufficient product.

Verify that the Auger Motor has 120 volts.

If yes, replace the Auger Motor. If the Auger 

Motor does not have 120 Volts, replace the UPM.

Not dispensing water on any selection:

Refer to

 TANK FILLING ISSUES.

Verify 120 volts at inlet valve coil

Replace Inlet Valve

Remove Orange wire from the Water

Level Probe. Does the Tank Fill?

Replace Water Level Probe. 

Replace UPM

Does the tank continue to fill after the toggle 

switch has been turned off ?

Yes:

No:

Yes:

No:

Replace Water Inlet Valve. 

Remove the Orange wire from the Wa-

ter Level Probe and connect it to ground. 

Does the tank stop filling?

Replace the Water Level Probe

Replace the UPM

Whipper Motor not running:

Verify that the propeller and chamber are

assembled correctly (not binding).

Verify that the Whipper Motor has 120 volts. If 

yes, replace the whipper motor. If the Whipper 

Motor does not have 120 volts, verify that the 

wiring is correct and unbroken.  If so, replace 

the UPM. 

i

If the Dispense valve on the same selection 

is operating, the UPM does not need to be 

replaced. The Whipper Motor and Dispense 

valve are powered together by the UPM.

Summary of Contents for PCGT3

Page 1: ...Service Sales 1 800 421 6150 www wilburcurtis com TROUBLESHOOTING GUIDE G3 PRIMO CAPPUCCINO SYSTEMS MODELS PCGT3 PCGT4 PCGT5 PCGT6...

Page 2: ...1006 06 CHAMBER WHIPPER OFFSET PCGTs 14 CA 1037 3Y TUBE EXTENSION YELLOW PART DESCRIPTION 15 WC 37118 KIT WHIPPER PLATE 3 PKG 16 CA 1024 05 PILLAR LOCATION BLACK 17 CA 1008 07K KIT PROPELLER WHIPPER...

Page 3: ...039 O RING DUMP VALVE 31 CA 1135 LATCH ASSY DOOR Service Sales 1 800 421 6150 www wilburcurtis com PART DESCRIPTION PCGT4 5 6 PARTS IDENTIFICATION 1 WC 37126 KIT UCM BOARD LABEL PCGT3 2 WC 5310 TUBING...

Page 4: ...EAR MOTOR GEAR 4 WC 6193 0 HEAT SINK ASSEMBLY 6 WC 780 CONTROL POWER MODULE 5 WC 3739 WHIPPING MOTOR 7 CA 1011 05 BULKHEAD WATER FITTING 9 CA 1095 CONNECTOR ORIFICE WATER 8 WC 43791 RING MOTOR SHAFT P...

Page 5: ...WC 3734 KIT DUMP VALVE 22 WC 2627 BUSHING CONICAL 20 WC 904 04 HEATING ELEMENT 23 WC 523 THERMOSTAT MNL RESET 25 WC 1438 101 SENSOR TEMPERATURE TANK 24 WC 102 SWITCH TOGGLE NON LIT 26 WC 37127 WC 371...

Page 6: ...L1 N 120 vac N G 0 vac if okay proceed to STEP 3 Verify that the toggle switch is turned on Verify 120 vac on both terminals No Replace Toggle Switch Yes Proceed to STEP 4 Verify that there is 120 vac...

Page 7: ...LING ISSUES Verify 120 volts at inlet valve coil Replace Inlet Valve Remove Orange wire from the Water Level Probe Does the Tank Fill Replace Water Level Probe Replace UPM Does the tank continue to fi...

Page 8: ...2014 M47_TS_WC_PCGT_revNC Wilbur Curtis Co Inc 6913 Acco Street Montebello CA 90640 Customer Service 800 421 6150 323 837 2300 csrassistance wilburcurtis com Tech Support 800 995 0417 www wilburcurtis...

Reviews: