background image

ROUGH-IN DRAWINGS 

RD77

GEM5IF - Intellifresh Satellite Stand

GEM5IF, ROUGH-IN DRAWING 

021518A

13.88 in 

[35.3 cm]

9.36 in 

[23.8 cm]

4.22 in 

[10.7 cm]

9.24 in 

[23.5 cm]

7.45 in 

[18.9 cm]

11.65 in 

[29.6 cm]

0.54 in 

[1.4 cm]

13.63 in 

[34.6 cm]

Summary of Contents for IntelliFresh GEM5IF

Page 1: ...tellite Stand USER GUIDE READ AND SAVE THESE INSTRUCTIONS NOTICE TO INSTALLER Please leave this booklet with the machine ø øø ø ø 5 30 5 07 3 SFW Style varies with model See brewer user guide for brewing instructions ...

Page 2: ... 240 Volt ES113 Product Warranty PW1 Contact Information Wilbur Curtis Co Inc 6913 Acco Street Montebello CA 90640 US Phone 323 837 2300 Toll Free 800 421 6150 Email csrassistance wilburcurtis com Web www wilburcurtis com PS UIF MBUFTU TQFDJmDBUJPOT BOE JOGPSNBUJPO HP UP XXX XJMCVSDVSUJT DPN 5PMM SFF POEBZ SJEBZ A M 4 00 P M PT Email techsupport wilburcurtis com VF UP DPOUJOVFE QSPEVDU JNQSPWFNFOU...

Page 3: ...tenance should be performed by an authorized Wilbur Curtis service technician 5P SFEVDF UIF SJTL PG mSF PS FMFDUSJD TIPDL 0 05 PQFO UIF TFSWJDF QBOFMT 5IFSF BSF OP VTFS serviceable parts inside Keep hands arms and other items away from hot surfaces during operation MFBO UIF VOJU SFHVMBSMZ BT JOTUSVDUFE JO UIF 4536 5 0 4 6TF UIJT BQQMJBODF POMZ GPS JUT JOUFOEFE VTF TVQQPSUJOH QPXFSJOH OUFMMJGSFTI d...

Page 4: ...rs Appliances can be used by persons 18 years and above with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children under the age of 18 years should be supervised to ensure they do not play with the appliance If the power cord is...

Page 5: ...NG HOT SURFACES To avoid injury allow the satellite stand to cool before cleaning 1 Disconnect the power cord or turn off power to the circuit supplying power at the circuit breaker panel 2 Remove the satellite s Wipe exterior surfaces with a damp cloth to remove spills and debris Dry with a soft clean cloth 3 Once dry reconnect power WARNING DO NOT immerse the satellite stand in water or any othe...

Page 6: ...OUGH IN DRAWINGS RD77 GEM5IF Intellifresh Satellite Stand GEM5IF ROUGH IN DRAWING 021518A 13 88in 35 3cm 9 36in 23 8cm 4 22in 10 7cm 9 24in 23 5cm 7 45in 18 9cm 11 65in 29 6cm 0 54in 1 4cm 13 63in 34 6cm ...

Page 7: ...INGS RD78 GEM5IFT Twin Intellifresh Satellite Stand GEM5IFT ROUGH IN DRAWING 021518A 13 93in 35 4cm 9 40in 23 9cm 4 23in 10 7cm 18 27in 46 4cm 18 35in 46 6cm 7 45in 18 9cm 11 70in 29 7cm 0 54in 1 4cm 13 68in 34 7cm ...

Page 8: ...OVER ASSY GEM5IF 4B WC 61382K KIT TOP COVER ASSY GEM5IFT 5 WC 61307 HOLDER CONNECTOR FEMALE GEMTIF ITEM PART DESCRIPTION 6A WC 165a SWITCH WARMER RED 120V NEON SPST 20A 250V HI TEMP CAFE AW 6B WC 166b SWITCH WARMER RED 250V NEON SPST 20A 250V HI TEMP CAFE AW 6C WC 135a b SWITCH ON OFF RED 220V WRMR 7A WC 3503 LEG 3 8 16 STUD SCREW BUMPER 7B WC 3528 LEG 4 ADJUSTABLE 3 8 16 THRD ITALIAN STYLE 7C WC ...

Page 9: ...SIFT ELECTRICAL SCHEMATICS ES111 Model Voltage V Amps A WaƩs W Hertz Hz of Conductor Wires Phase of Elements Inside GEM3IF Element RaƟng W V GEM5IFx 120 0 60 71 50 60 2 1 1 75W 120V ELECTRICAL RATING TABLE 53 4 5 ø ...

Page 10: ...T ELECTRICAL SCHEMATICS ES112 Model Voltage V Amps A WaƩs W Hertz Hz of Conductor Wires Phase of Elements Inside GEM3IF Element RaƟng W V GEM5IFTx 120 1 20 142 50 60 2 1 1 2x 75W 120V ELECTRICAL RATING TABLE 5 53 4 5 ø ...

Page 11: ...ICS ES110 Model Voltage V Amps A WaƩƐ W Hertz Hz of Conductor Wires Phase of Elements Inside GEM3IF30 Element RaƟng W V 220 0 32 71 230 0 34 78 240 0 35 85 75W 220V ELECTRICAL RATING TABLE 1 1 2 0 6 0 5 x 0 3 F I 5 M E G 53 4 5 ø ...

Page 12: ... ES113 Model Voltage V Amps A Wa s W Hertz Hz of Conductor Wires Phase of Elements Inside GEM3IF30 Element Ra ng W V 220 0 65 142 230 0 67 155 240 0 70 169 75W 220V ELECTRICAL RATING TABLE 1 1 2 0 6 0 5 x 0 3 T F I 5 M E G 5 53 4 5 ø ...

Page 13: ...cal and plumbing codes Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment Improper water supply 7KLV LQFOXGHV EXW LV QRW OLPLWHG WR H FHVVLYH RU ORZ ZDWHU SUHVVXUH DQG LQDGHTXDWH RU ÀXFWXDWLQJ ZDWHU ÀRZ UDWH Damaged in transit Equipment damaged in transit is the responsibility of the freight company and a claim should be made with th...