Installation
Leveling
1 Position the brewer on the counter top. Level it left to
right and front to back by turning the bottom of the
legs.
Connect the Water Supply
2 Flush the water supply line prior to installation to
QVSHFBJSBOEEFCSJTGSPNUIFXBUFSmMUFSBOEUVCJOH
3
$POOFDUUIFXBUFSTVQQMZMJOFUPUIFnBSFmUUJOHPO
the back of the brewer. Leave the water supply valve
closed until the power is connected.
Connect the Brewer Wiring
Brewers Without A Cord Set Attached
4 Remove the screws that hold the front cover in place
and remove the cover.
5 Loosen the strain relief on the back of the brewer.
6 On dual voltage units being operated at 220 Volts
(nominal) disconnect the existing power cable from
the terminal block and remove.
7 Feed the 220 Volt power cable into the brewer.
8 On dual voltage units being operated at 220 Volts,
disconnect and cap the jumper wire between the “C”
and “N” terminals on the terminal block.
9 Connect the wires on the power cable to the terminal
block inside the brewer.
10 Tighten the strain relief and replace the front cover.
11 Connect the power cable wires to the terminals in the
junction box. See the
ELECTRICAL SCHEMATIC
for
the power supply requirements.
INSTALLATION INSTRUCTIONS
II8
DECANTER/DISPENSER BREWERS, INSTALLATION INSTRUCTIONS
122717A
WARNING:
Use the leveling legs to level the
brewer only. Do not use them to adjust brewer
height. Do not extend them higher than necessary.
Front
panel
WARNING:
Turn off power to the junction box at
the circuit breaker panel before connecting the
power cable to the brewer.
Terminal
block