The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use.  The following limited 

warranties and conditions apply:

Years, Parts and Labor, from Original Date of Purchase on digital control boards

.

Years, Parts, from Original Date of Purchase on all other electrical components, fittings and tubing.

Year, Labor, from Original Date of Purchase on all electrical components, fittings and tubing.

Additionally, the Wilbur Curtis Company warrants its Grinding Burrs for Forty (40) months from date of purchase or 40,000 pounds of coffee, 

whichever comes first.  Stainless Steel components are warranted for two (2) years from date of purchase against leaking or pitting and replace-

ment parts are warranted for ninety (90) days from date of purchase or for the remainder of the limited warranty period of the equipment in which 

the component is installed.

All in-warranty service calls must have prior authorization.  For Authorization, call the Technical Support Department at 1-800-995-0417.  Effective 

date of this policy is April 1, 2003.

Additional conditions may apply.  Go to www.wilburcurtis.com to view the full product warranty information.

CONDITIONS & EXCEPTIONS

The warranty covers original equipment at time of purchase only. The Wilbur Curtis Company, Inc., assumes no responsibility for substitute replace-

ment parts installed on Curtis equipment that have not been purchased from the

Wilbur Curtis Company, Inc.  The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty 

does not cover and is void under the following circumstances:

1)  Improper operation of equipment:  

The equipment must be used for its designed and intended purpose and function.

2)  Improper installation of equipment: 

 This equipment must be installed by a professional technician and must comply with all local electrical, 

mechanical and plumbing codes.

3)  Improper voltage:  

Equipment must be installed at the voltage stated on the serial plate supplied with this equipment.

4)  Improper water supply:  

This includes, but is not limited to, excessive or low water pressure, and inadequate or fluctuating water flow 

rate.

5)  Adjustments and cleaning:  

The resetting of safety thermostats and circuit breakers, programming and temperature adjustments are the 

responsibility of the equipment owner.  The owner is responsible for proper cleaning and regular maintenance of this equipment.

6)  Damaged in transit:  

Equipment damaged in transit is the responsibility of the freight company and a claim should be made with the car-

rier. 

7)  Abuse or neglect (including failure to periodically clean or remove lime accumulations):  

Manufacturer is not responsible for variation 

in equipment operation due to excessive lime or local water conditions.  The equipment must be maintained according to the manufacturer’s 

recommendations.

8)  Replacement of items subject to normal use and wear:  

This shall include, but is not limited to, light bulbs, shear disks, “0” rings, gaskets, 

silicone tube, canister assemblies, whipper chambers and plates, mixing bowls, agitation assemblies and whipper propellers.

9)  Repairs and/or Replacements 

are subject to our decision that the workmanship or parts were faulty and the defects showed up under normal 

use.  All labor shall be performed during regular working hours. Overtime charges are the responsibility of the owner.  Charges incurred by 

delays, waiting time, or operating restrictions that hinder the service technician’s ability to perform service is the responsibility of the owner 

of the equipment.  This includes institutional and correctional facilities.  The Wilbur Curtis Company will allow up to 100 miles, round trip, per 

in-warranty service call.

RETURN MERCHANDISE AUTHORIZATION:  

All claims under this warranty must be submitted to the Wilbur Curtis Company Technical 

Support Department prior to performing any repair work  or return of this equipment to the factory.  All returned equipment must be repackaged 

properly in the original carton. No units will be accepted if they are damaged in transit due to improper packaging.  

NO UNITS OR PARTS WILL 

BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA).  RMA NUMBER MUST BE MARKED ON THE CARTON 

OR SHIPPING LABEL.  All in-warranty service calls must be performed by an authorized service agent.  Call the Wilbur Curtis Technical Sup-

port Department to find an agent near you.

Summary of Contents for EXPR

Page 1: ...WILBUR CURTIS CO Montebello CA 90640 For the latest information go to www wilburcurtis com Tel 800 421 6150 This equipment is designed for commercial use Any servicing other than cleaning and routine maintenance should be performed by an authorized Wilbur Curtis Company Service Technician DO NOT immerse the unit in water or any other liquid To reduce the risk of fire or electric shock DO NOT open ...

Page 2: ...flavor by pressing and holding the WASH button at the same time pressing one of the PUSH dispensing buttons on the control panel Continue holding WASH until the rinse water runs clear D Dispose of rinse water container and it s contents II DAILY Refer to the daily cleaning instructions on the inside of the front door see il lustration below A Switch OFF the unit at the power toggle switch located ...

Page 3: ...not be covered under warranty 8 Clean the mounting plate a Clean the shaft with a cloth and mild detergent before removing mounting plate b Twist the mounting plate clockwise and pull it from the motor shaft c Clean the area behind the mounting plate d Clean the water inlet fitting e Lubricate the center seal of the mounting plate before reinstalling 9 Wash and rinse all parts that were removed fo...

Page 4: ...able from 170 F to 204 F in 2 degree increments Press or to go up or down in degrees Select desired temperature and then to set Press to continue to the next menu Powder Ratio Press and the screen will display Powder Ratio Select Station This is shown as A B C D and E corresponding to canisters arranged left to right when facing the machine starting with A Press desired station Powder ratio for ea...

Page 5: ... EXPR A B C D E Before mounting a whipper plate place a dab of food grade lubricant in the rear hole of the seal Shaft seals should be replaced with the groved side facing outward Place a dab of food grade lubricant in the rear hole of the seal as shown below Whipper Plate Shaft Seals Rough In Drawing ...

Page 6: ... 68191 WC 68175 WC 58232 WC 68174 WC 68192 CA 1123 CA 1143 WC 37298 Item Part Description LABEL UCM PANEL CANISTER ASSY ULTRA SLIM CANISTER ASSY 10LB RIGHT PCGTs LAMP COMPLETE W 5K BULB ELBOW PC CK HC ELBOW CANISTER RIGHT ELBOW CANISTER LEFT MOTOR WHIPPER FITTING BULKHEAD WATER 10 11 12 13 14 15 16 17 18 WC 39608 CA 1142 06 CA 1113 06R CA 1127 CA 1026 03 CA 1026 06 CA 1026 07 WC 3739 CA 1011 05 It...

Page 7: ...ATION BLACK MANIFOLD 3 IN 1 BARISTA 19 20 21 22 23 24 25 26 27 CA 1005 03 CA 1095 CA 1009 03 WC 37118 CA 1008 07K CA 1006 06 WC 43791 CA 1024 05 CA 1152 Item Part Description COVER ALCOVE SCREEN DRIP TRAY DRIP TRAY LID CANISTER ULTRA SLIM LID CANISTER 10LB PCGT s KIT SOCKET GEAR PC CK HC GEAR PLASTIC USE ON CA 1013 s KIT GEAR MOTOR CORK BRAKE PCGT VALVE INLET 28 29 30 31 32 33 34 35 36 CA 1163 WC ...

Page 8: ...ODELS UNIVERSAL POWER MODULE EXPR LEG GUIDE 3 8 16 STUD SCREW COMPOUND SILICONE 5 OZ TUBE TUBE 5 16 ID X 1 8 w SILICONE HOSE EXTRACTOR FAN 23 LONG FAN EXTRACT 120V 29CFM 60Hz KIT INLET VALVE REPAIR USE ON WC 826L LEG 3 8 16 STD SCREW BUMPER KIT TANK LID ROUND INSULATION WRAP PCGT KIT LIQUID LEVEL PROBE BUSHING CONICAL 583 ID x 945 OD x 945 L KIT RPL DUMP VALVE FOR WC 880E HEATING ELEMENT 1 45KW W ...

Page 9: ...9 Electrical Diagram TANK WATER ...

Page 10: ...Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility...

Reviews: