background image

1

Symbols

WARNINGS – To help avoid personal injury

Important Notes/Cautions – from the factory

Sanitation Requirements

CAUTION: DO NOT 

connect this brewer to hot 

water. The inlet valve is 

not rated for hot water.

CAUTION: Please use 

this setup procedure 

before attempting to use 

this brewer. Failure to follow the 

instructions can result in injury or the 

voiding of the warranty.

Model

  • D1000GT

3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the ‘ON’ position (located on the rear of 

the unit), the water tank will begin to fill. When the water level in the tank reaches the probe, the heating 

element(s) will turn on. 

5. Water in the heating tank will require approximately a half hour before reaching operating temperature (factory 

setting of 200°F). Where applicable, turn on the Universal Control Module (UCM). When the unit reaches 

operating temperature, it will display “READY TO BREW”.

W

ilbur

 C

urtis

 C

o

., i

nC

.

Service Manual – D1000GT Airpot Brewer

Important Safeguards & Symbols

This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance 

should be performed by an authorized Wilbur Curtis service technician.
  • Do NOT immerse the unit in water or any other liquid
  • To reduce the risk of fire or electric shock, do NOT open service panels. No user serviceable parts inside.
  • Keep hands and other items away from hot surfaces of unit during operation.
  • Never clean with scouring powders, bleach or harsh chemicals.

The Curtis G3 airpot brewer is Factory Pre-Set and Ready to Go… Right from the Box.
Following are the Factory Settings for Curtis airpot brewers:

  • Brew Temperature = 200°F
  • Brew Volume = Set to vessel requirements (75 oz).
System Requirements:

  • Water Source   20 – 90 PSI (minimum flow rate of 1 GPM)
  • Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model. 

Setup Steps

1.  The unit should be level (left to right - front to back), on a secure surface.  
2.  Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine 

should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of 1 GPM.

NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be purged 

from the cartridge prior to connection to equipment. In areas with extremely hard water, we highly 

recommend the use of a Curtis approved water filter. For our full line of filters, please log on to www.wilbur-

curtis.com.

NSF International requires the following water connection:

1.  A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit 

can be moved for cleaning.

2.  This unit must be installed with adequate backflow protection to comply with applicable federal, state and 

local codes.

3.  Water pipe connections and fixtures directly connected to a portable water supply shall be sized, installed 

and maintained in accordance with federal, state, and local codes.

For the latest specifications and information go to www.wilburcurtis.com

Technical Support: 1-800-995-0417 M-F 5:30 am - 4:00 pm PT

Email: [email protected]

ISO 9001:2008 REGISTERED

WILBUR CURTIS CO., INC.

6913 West Acco Street

  Montebello, CA 90640-5403

For the latest information go to 

www.wilburcurtis.com

Tel: 800-421-6150

Fax: 323-837-2410

Summary of Contents for D1000GT

Page 1: ...Pre Set and Ready to Go Right from the Box Following are the Factory Settings for Curtis airpot brewers Brew Temperature 200 F Brew Volume Set to vessel requirements 75 oz System Requirements Water Source 20 90 PSI minimum flow rate of 1 GPM Electrical See attached schematic for standard model or visit www wilburcurtis com for your model Setup Steps 1 The unit should be level left to right front t...

Page 2: ...w the buttons are Scroll LEFT SELECTION or ENTER to save new parameter Scroll RIGHT Brewing Instructions 1 Brewer should be ON Confirm at rear toggle switch then press ON OFF button Ready to Brew on screen 2 Open the lid on an empty airpot and place it on the brew deck Be careful to center it under the brew cone 3 Place a new filter into the brew cone 6 Press the BREW button to start brewing 5 Pos...

Page 3: ...ently programmable for Brew Volume volume or time Pre infusion and Pulse Brew During actual brew cycle a 2 minute drip mode is added to the brew time Brew Count Total Press to Select Shows total gallons and total brew cycles on the unit Cannot be reset Cold Brew Lock Factory set to 5º Press to select to select desired setting 5º 15º or OFF to set The Cold Brew Lock feature allows the brewer to bre...

Page 4: ...ear for six seconds Model Select Factory set to D1000GT Press to select Press or to toggle between D1000GT and D500GT 2Batch Press to set Exit Press to select exits program mode and returns unit to operation Pressing returns you to Brew By Volume Exit Drip Out Mode Display Brew Time Display Messages Model Select LEG 3 8 16 STUD SCREW TANK COMPLETE D1000GT 220V TANK COMPLETE D1000GT 120 220V DV VAL...

Page 5: ...5 20 31 22 1 2 3 4 5 A B C 6 7 8 9 10 11 12 13 14 15 16 17 18 19 21 B 24 25 26 28 27 29 30 C 23 Parts Diagram ...

Page 6: ...st or debris from the exterior surfaces with a damp cloth Apply a stainless steel polish to prevent scratches 3 Wipe down the spray head area with a moist cloth 4 Slide out the brew cone and clean it with a mild detergent solution 5 Turn on the brewer at the ON OFF button CAUTION DO NOT use undiluted bleach or chlorine Cleaning Airpots 1 Clean with warm water and dish washing detergent Use a spong...

Page 7: ...7 Electrical Schematic Dual Voltage ...

Page 8: ...al and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustment...