3
Your Curtis G3/Gold Cup Series is Factory Pre-Set for Optimum Performance.
After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller.
The control displays
. Press ON/OFF button and the screen will display
. After three seconds,
is displayed.
Water will fill the tank (approximately 2-3 minutes depending on water flow rate). When the proper level is reached
will appear on the screen.
It takes approximately 20 minutes to reach set point temperature.
Control will display
when temperature reaches the set point. Unit is now ready to brew.
<CBHVS>
CURTIS
CURTIS
CURTIS
READY TO BREW
CURTIS
FILLING
CURTIS
HEATING
PROGRAM MENUS COMBO BREWER
Program Menus
From
Program Menus
press > display will show the next feature Global Recipes.
Global Recipes (Factory set to Gourmet STD)
This is a coffee option. Press
to select. If selected, press < or > to
chose a coffee recipe: Gourmet STD, Light Roast, Dark
Roast, High Yield, Filter Pack, or Decaf.
Press
to select the desired recipe.
Non-Brew Program
Press
to Select or < > to pass by these options and continue to the next group. The selections for Non-Brew Program are
listed below.
Temperature (Factory set to 204ºF)
Press
to Select. Press < or > to move to desired temperature and then
to set. Temperature is programmable from 170ºF
to 208ºF in 2-degree increments.
Energy Save Mode (Factory set to OFF)
Press
to Select, < or > ON, OFF or ON 140ºF ,
to set. When in ON, unit will automatically shut off 4 hours from last
brew. When feature is OFF, unit does not utilize the energy saving mode.
In the ON 140ºF position, temperature lowers to 140ºF, if unit has not brewed in 4 hours. This feature will save energy by main
-
taining a lower temperature in the tank in periods of non-operation.
Brew Count Odom
Press
to display total brew cycles. Press EX or Reset.
Brew Count Total
Press
to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Temperature
Energy Save Mode
Brew Count Odom
Global Recipes
Non-Brew Program
Brew Count Total
Programming with the Universal Control Module (UCM)
Turn off the control panel by pressing ON/OFF button. Press and hold
bottom/right coffee brew button (#4 in illustration) and then press and release the ON/OFF button.
Continue holding the bottom-right brew button. The screen will display
, wait until
is displayed. Enter the 4-digit access code, the code corresponds to
the buttons illustrated below. The default code set at the factory is 1-2-3-4.
After the 4-digit code is entered,
will be displayed. You can now enter the program menu features.
ENTER CODE
– – – –
PROGRAM MENUS
< SELECT >
ENTERING
PROGRAM MODE
All programming selections are performed with the three center buttons.
The symbols near the buttons are:
Scroll LEFT
SELECTION or ENTER to save new parameter
Scroll RIGHT
4
3
1
2