When the water level gets below the probe tip, water should automatically refill the tank. 

If not, pull wire off the probe terminal. Water should now start flowing into the tank. If not, 

check the water level control board (see step 4) or inlet valve (step 2).

Disconnect wire from probe terminal. With a voltmeter, check voltage at the water inlet 

coil terminals. This should read 110-120 volts. If no voltage is present, check liquid level 

control (L.L.C.) board. Make sure the L.L.C. board is supplied by 120V across terminals 

T2 & T3. The L.L.C. board is grounded to the chassis of the machine by contacting the 

board to the mounting bracket. Make sure board is grounded here. Check for loose con-

nections at terminals. Replace board.

POSSIBLE CAUSE

SOLUTION

3.   Grounded probe

4.  Defective water level control    

  board

TROUBLE SHOOTING CONTINUED:

PROBLEM: 

WATER DOES NOT FLOW INTO HEATING TANK.

PROBLEM: 

WATER HEATING TANK OVERFLOWING.

POSSIBLE CAUSE

SOLUTION

Turn power off and observe water level. If water continues to flow into the heating tank, 

clean or replace leaky valve.

Disconnect wire from probe terminal. Touch the body of the heating tank with the 

terminal at the end of this wire. If water stops, try cleaning the probe. Probe may have 

to be replaced.

Liquid level control board must be securely grounded through the back of the board 

and the mounting bracket. Check for loose connections at the terminals. Check for 

voltage across the inlet valve terminals. If there is 110 to 120 volts present at the inlet 

valve terminals when water level is touching the probe tip, replace the L.L.C. board.

1.  Defective water inlet valve

2.  Probe limed-up

3.  Non-grounded or loose terminal  

  connections at liquid level  

  control board

POSSIBLE CAUSE

SOLUTION

1.  Thermostat turned 

OFF

  

  (or not fully ON).

2.   Defective thermostat

3.   Defective Contactor

Check thermostat to make sure the shaft is rotated fully clockwise until it stops.

Replace thermostat if contacts are open when shaft is fully clockwise and water temper-

ature is less than 190º F. You will measure 120 volts (approximately) to ground from both 

thermostat terminals when it is ON and from only one terminal when it is OFF.

Measure the voltage across the coil terminals of the contactor. If you read 110/120V, but 

the contacts remain open, the coil is burned out. Replace it.

PROBLEM: 

WATER IN TANK DOES NOT REACH PROPER TEMPERATURE

[ 4 ]

C1000AP & C1000APT Airpot Brewer

Summary of Contents for C1000AP

Page 1: ...SERVICE MANUAL C1000AP C1000APT DUAL AIRPOT BREWERS Montebello California 90640 Telephone 323 837 2300 Fax 323 837 2406 Wilbur Curtis Co Inc...

Page 2: ...SERVICE MANUAL FILTER PAPER FITTING 1 4 x 3 8 FLARE ELBOW CARTON CONTENTS C1000AP APT ROUGH IN DRAWING Subject Shipping List Dimensions Introduction Setting Up Brewing Care Maintenance Trouble Shooti...

Page 3: ...l is approximately two inches below probe tip 2 A 1 4 are tting is required to hook up the water inlet Connect water line to inlet valve tting Turn on water 3 With top cover removed locate the thermos...

Page 4: ...an empty airpot beneath the cone Notethatmostairpotsmustbeopenedandthesiphon assembly removed for lling Preheating the airpot can increase the serving tem perature by 4 5 F Make sure that both the ON...

Page 5: ...er This is to prevent scratching of the stainless steel surfaces CAUTION Do not use cleansers bleach liquids powders or any other substance containing chlorine These products will promote corrosion an...

Page 6: ...h the body of the heating tank with the terminal at the end of this wire If water stops try cleaning the probe Probe may have to be replaced Liquid level control board must be securely grounded throug...

Page 7: ...tat shaft counterclockwise until brew light comes on and boiling stops SOLUTION POSSIBLE CAUSE 1 Water level is too low in heating tank 2 Defective brew switch 3 Defective brew valve 4 Clogged ttings...

Page 8: ...6 ILLUSTRATED PARTS BREAKDOWN C1000AP C1000APT Airpot Brewer...

Page 9: ...7 ILLUSTRATED PARTS BREAKDOWN C1000AP C1000APT Airpot Brewer 43 42...

Page 10: ...NTROL LEVEL CONTROL WATER 120V TIMER BREW 120V 1 8MIN VALVE DUMP RIGHT 120V 12W VALVE DUMP LEFT 120V 12W INDEX N PART N WC 5310 WC 517 WC 4320 WC 2977 WC 826L WC 2401 WC 5482 WC 3502 WC 3709 WC 102 WC...

Page 11: ...9 C1000AP C1000APT Airpot Brewer...

Page 12: ...it due to improper packaging NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION RMA RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL All in warranty service calls m...

Reviews: